China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Med-tronic |
Model Number: | Lifepak LP20 |
Minimum Order Quantity: | 1 |
---|---|
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union,PayPal |
Product Name: | Med-tronic Lifepak LP20 Defibrillator | Type: | Lifepak LP20 |
---|---|---|---|
Application: | Medical Equipment,ICU,hospital Device | Warranty: | 90days |
Color: | Green | Key Words: | Therapy Board And Pacing Board |
Language: | Multiple Languages | Superiority: | Specialized Engineers With 12 Years Of Experience |
Sale Protection: | If We Find Non-human Damage, We Will Be Free For You To Repair Or Returned | Product State: | Run Well |
AC Input Voltage Rate: | 110V—240v | Power Supply Source: | Electric |
Inventory: | In Stock | Method Of Transport: | Expressage |
MOQ: | 1pcs | ||
High Light: | 3200926-004 IrDA Assembly,Defibrillator W03 IrDA Assembly |
Med-tronic Physio-Control Lifepak LP20 Defibrillator W03 IrDA Assembly 3200926-004
► Brief Introduction
The W03 IrDA Assembly is used to provide high-speed wireless communications to data management devices. The OEM W03 IrDA port supports IrDA version 1.1 communications with asynchronous serial rates up to 4 Mbits/second. The IrDA port is mounted directly on the bottom case and the flex circuit connects directly to the A01 System Control PCB at J08. An infrared lens is molded into the device front case directly in front of the IrDA port. The IrDA port and front case lens are aligned so that direct communications can easily be made with a portable data receiver held by an operator or placed on a table.
► To remove the W03 IrDA Assembly:
► To install the W03 IrDA Assembly:
► Specification
Energy Select: | 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 50, 70, 100, 125, 150, 175, 200, 225, 250, 275, 300,325, and 360 joules and user configurable sequence of 100–360, 100–360, 100–360 joules |
Charge time: | – Charge time to 200J <5 seconds with fully charged battery – Charge time to 360J <7 seconds with fully charged battery – Charge time to 360J <10 seconds while not in low battery operations |
Synchronized Cardioversion: | – Energy transfer begins within 60 ms of the QRS peak – Energy transfer begins within 25 ms of the External Sync Pulse – External Sync Pulse; 0–5V (TTL Level) Pulse, active High, > 5 ms in duration, no closer than 200 ms apart and no further than 1 second apart |
Thank you for your time and interest in Med-tronic Physio-Control Lifepak LP20 Defibrillator W03 IrDA Assembly 3200926-004. If you want to explore more details please let us know.
Contact Person: Rita
Tel: 8618279091952