Product Details:
Brand Name: Med-tronic
Model Number: Lifepak LP20
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Med-tronic Lifepak LP20 Defibrillator Type: Lifepak LP20
Application: Medical Equipment,ICU,hospital Device Warranty: 90days
Color: Green Key Words: Therapy Board And Pacing Board
Language: Multiple Languages Superiority: Specialized Engineers With 12 Years Of Experience
Sale Protection: If We Find Non-human Damage, We Will Be Free For You To Repair Or Returned Product State: Run Well
AC Input Voltage Rate: 110V—240v Power Supply Source: Electric
Inventory: In Stock Method Of Transport: Expressage
MOQ: 1pcs
High Light:

3200926-004 IrDA Assembly

,

Defibrillator W03 IrDA Assembly

 

Med-tronic Physio-Control Lifepak LP20 Defibrillator W03 IrDA Assembly 3200926-004

 

 

 

► Brief Introduction

The W03 IrDA Assembly is used to provide high-speed wireless communications to data management devices. The OEM W03 IrDA port supports IrDA version 1.1 communications with asynchronous serial rates up to 4 Mbits/second. The IrDA port is mounted directly on the bottom case and the flex circuit connects directly to the A01 System Control PCB at J08. An infrared lens is molded into the device front case directly in front of the IrDA port. The IrDA port and front case lens are aligned so that direct communications can easily be made with a portable data receiver held by an operator or placed on a table.

 

 

 

To remove the W03 IrDA Assembly:

  1. If the boardstack is not removed, disconnect the W03 IrDA flex cable from the A01 System PCB at J8 by first removing the screw using a 3/32 allen driver.
  2. Insert a slotted screwdriver into the slot between the bottom case cutout (A) and the right snap tab (B).
  3. Gently apply pressure to the screwdriver. Bend the right IrDA snap tab (B) outward slightly, freeing the right edge of the W03 IrDA Assembly.
  4. Remove the W03 IrDA Assembly from the bottom case.
  5. If the boardstack is still installed in the bottom case, disconnect the IrDA connector from PCB.

 

 

To install the W03 IrDA Assembly:

  • Position the W03 IrDA Assembly on the bottom case. (The IrDA is located near the center of the front panel on the bottom case.)
  • Insert a large slotted screwdriver into the slot between the bottom case cutout (A) and the right snap tab (B).
  • Gently apply pressure to the screwdriver. Bend the right IrDA snap tab (B) slightly outward,
  • Press the W03 IrDA Assembly down into the snap tabs and release the pressure on the screwdriver. The snap tabs will close around the W03 IrDA Assembly.
  • Ensure that the W03 IrDA Assembly is resting centered on the support brackets and snap tabs.
  • Connect the W03 IrDA Assembly to the A01 System PCB and fasten with a screw using a 3/32 allen driver, if the boardstack is still installed in the bottom case. Otherwise, Install the boardstack. The IrDA flex cable is connected during the boardstack installation

Med-tronic Lifepak LP20 Defibrillator W03 IrDA Assembly 3200926-004 0

 

 

 

► Specification

Energy Select: 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 50, 70, 100, 125, 150, 175, 200, 225, 250, 275, 300,325, and 360 joules and user configurable sequence of 100–360, 100–360, 100–360 joules
Charge time: – Charge time to 200J <5 seconds with fully charged battery
– Charge time to 360J <7 seconds with fully charged battery
– Charge time to 360J <10 seconds while not in low battery operations
Synchronized Cardioversion: – Energy transfer begins within 60 ms of the QRS peak
– Energy transfer begins within 25 ms of the External Sync Pulse
– External Sync Pulse; 0–5V (TTL Level) Pulse, active High, > 5 ms in duration, no closer than 200 ms apart and no further than 1 second apart

 

 

 

Thank you for your time and interest in Med-tronic Physio-Control Lifepak LP20 Defibrillator W03 IrDA Assembly 3200926-004. If you want to explore more details please let us know.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.