Zoll M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12

Zoll M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12

  • Zoll M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12
  • Zoll M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12
  • Zoll M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12
  • Zoll M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12
  • Zoll M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12
  • Zoll M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12
  • Zoll M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12
  • Zoll M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12
Zoll M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12
Product Details:
Brand Name: ZOLL
Certification: CE/CB/ROSH
Model Number: M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD
Packaging Details: Carton
Payment Terms: L/C, D/A, D/P, T/T
Contact Now
Detailed Product Description
Brand: Zoll M Series E Series R Series Defibrilator ECG Lead Cable Color: Black
Material: Cable Wattanty: 90 Days
Packing Weight: 1Kg Interface Cable: Multiple Lines
Application Area: Defibrilator ECG Lead Cable Condition: Original Brand New
Estimated Ship Time: 3-5 Business Days Depth0: 1.5m
Width: 6cm Height: 1.5m
Net Weight: 0.45kg Shape: Long Shape
High Light:

8000-0350-12 Defibrilator ECG Lead Cable

,

Defibrilator ECG Lead Cable

Zoll M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12

 

 

Quick Detail:

 

There are several steps when selecting the ECG lead cable to connect to a defibrillator:
1. Turn on the power and check the synchronization performance, select the higher lead for R-wave inspection.
2. After anesthesia is performed as required, the electrode pads must be placed as required.
3. You must choose the amount of charging energy to ensure safe use of electricity.
4. Unrelated personnel should not come into contact with the patient, hospital bed or equipment connected to the patient.
5. ECG, blood pressure, respiration and consciousness should be monitored after electric shock.

 

Zoll M Series E Series R Series Defibrilator ECG Lead Cable 8000-0350-12 0

 

Key features:

 

Product Category Defibrilator ECG Lead Cable
Use  Equipment Zoll M Series E Series R Series Defibrilator
Package Weight 0.2 kg
Packaging Unit more lead set
CE Certified Yes
Size 1.5m*6cm
Patient Application Child; Adult

 

 

FAQ:

 

Do the ECG monitoring leads need to be removed during defibrillation?
Answer: This requires checking whether the ECG monitoring leads equipped with the bedside ECG monitor are defibrillation-proof ECG lead wires. If it is a defibrillation-proof ECG lead wire, it does not need to be removed during defibrillation. Otherwise, the bedside ECG monitoring wire needs to be removed.

 

When defibrillating, should I choose lead II or lead Paddles? Is there a difference between the two?
Answer: When using a defibrillator for ECG monitoring, lead II should be selected; if a defibrillator is not used to monitor the patient's heart rhythm, when the patient suddenly changes and it is judged that defibrillation is needed, the lead should be immediately adjusted to Paddles lead. , which makes it easier to check whether the patient has ventricular fibrillation or pulseless ventricular tachycardia before charging for defibrillation. Because after choosing Paddles leads, you only need to place the two electrode pads on the chest to check the patient's heart rhythm, which is much faster than checking the heart rate by connecting cable leads and pasting electrode pads.

 

How to monitor whether the monitoring function of the defibrillator is intact?
Answer: Select the lead as Paddles lead, and touch the sternum and apex electrode pads with both hands respectively. If the ECG waveform is displayed on the screen, it means that the monitoring function of the defibrillator is good.

 

Is it necessary to check the defibrillator every day and check the system time on the instrument?
Answer: Yes, the power plug should be unplugged every day and the defibrillator should be tested to ensure smooth use during rescue. You also need to pay attention to the system time and calibrate it according to the time. Because after each defibrillation operation, the instrument will automatically print a record based on the system time. If the system time is wrong, you will face embarrassment when providing evidence in medical disputes. Currently, there are quality standards that stipulate that the time difference between the defibrillator and Beidi cannot be greater than 2 minutes.

 

 

 

About delivery:

 

 

We default to express delivery by DHL. We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.

 

 

 

 

 

 

 

 

 


 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Mandy

Tel: +8615070124795

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.