Brand: | Zoll M Series E Series R Series Defibrilator ECG Lead Cable | Color: | Black |
---|---|---|---|
Material: | Cable | Wattanty: | 90 Days |
Packing Weight: | 1Kg | Interface Cable: | Multiple Lines |
Application Area: | Defibrilator ECG Lead Cable | Condition: | Original Brand New |
Estimated Ship Time: | 3-5 Business Days | Depth0: | 1.5m |
Width: | 6cm | Height: | 1.5m |
Net Weight: | 0.45kg | Shape: | Long Shape |
High Light: | 8000-0350-12 Defibrilator ECG Lead Cable,Defibrilator ECG Lead Cable |
There are several steps when selecting the ECG lead cable to connect to a defibrillator:
1. Turn on the power and check the synchronization performance, select the higher lead for R-wave inspection.
2. After anesthesia is performed as required, the electrode pads must be placed as required.
3. You must choose the amount of charging energy to ensure safe use of electricity.
4. Unrelated personnel should not come into contact with the patient, hospital bed or equipment connected to the patient.
5. ECG, blood pressure, respiration and consciousness should be monitored after electric shock.
Product Category | Defibrilator ECG Lead Cable |
Use Equipment | Zoll M Series E Series R Series Defibrilator |
Package Weight | 0.2 kg |
Packaging Unit | more lead set |
CE Certified | Yes |
Size | 1.5m*6cm |
Patient Application | Child; Adult |
Do the ECG monitoring leads need to be removed during defibrillation?
Answer: This requires checking whether the ECG monitoring leads equipped with the bedside ECG monitor are defibrillation-proof ECG lead wires. If it is a defibrillation-proof ECG lead wire, it does not need to be removed during defibrillation. Otherwise, the bedside ECG monitoring wire needs to be removed.
When defibrillating, should I choose lead II or lead Paddles? Is there a difference between the two?
Answer: When using a defibrillator for ECG monitoring, lead II should be selected; if a defibrillator is not used to monitor the patient's heart rhythm, when the patient suddenly changes and it is judged that defibrillation is needed, the lead should be immediately adjusted to Paddles lead. , which makes it easier to check whether the patient has ventricular fibrillation or pulseless ventricular tachycardia before charging for defibrillation. Because after choosing Paddles leads, you only need to place the two electrode pads on the chest to check the patient's heart rhythm, which is much faster than checking the heart rate by connecting cable leads and pasting electrode pads.
How to monitor whether the monitoring function of the defibrillator is intact?
Answer: Select the lead as Paddles lead, and touch the sternum and apex electrode pads with both hands respectively. If the ECG waveform is displayed on the screen, it means that the monitoring function of the defibrillator is good.
Is it necessary to check the defibrillator every day and check the system time on the instrument?
Answer: Yes, the power plug should be unplugged every day and the defibrillator should be tested to ensure smooth use during rescue. You also need to pay attention to the system time and calibrate it according to the time. Because after each defibrillation operation, the instrument will automatically print a record based on the system time. If the system time is wrong, you will face embarrassment when providing evidence in medical disputes. Currently, there are quality standards that stipulate that the time difference between the defibrillator and Beidi cannot be greater than 2 minutes.