Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsDefibrillator Machine Parts

Nihon Kohden Cardiolife TEC-7621C Defibrillator Test Load Board UR-0251 6190-022656-S Medical Equipment Sapre Parts

Nihon Kohden Cardiolife TEC-7621C Defibrillator Test Load Board UR-0251 6190-022656-S Medical Equipment Sapre Parts

  • Nihon Kohden Cardiolife TEC-7621C Defibrillator Test Load Board UR-0251 6190-022656-S Medical Equipment Sapre Parts
  • Nihon Kohden Cardiolife TEC-7621C Defibrillator Test Load Board UR-0251 6190-022656-S Medical Equipment Sapre Parts
  • Nihon Kohden Cardiolife TEC-7621C Defibrillator Test Load Board UR-0251 6190-022656-S Medical Equipment Sapre Parts
  • Nihon Kohden Cardiolife TEC-7621C Defibrillator Test Load Board UR-0251 6190-022656-S Medical Equipment Sapre Parts
Nihon Kohden Cardiolife TEC-7621C Defibrillator Test Load Board UR-0251 6190-022656-S Medical Equipment Sapre Parts
Product Details:
Brand Name: Nihon Kohden
Model Number: UR-0251
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Packaging Details: Standard Export Packing
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union, Paypal
Contact Now
Detailed Product Description
Price: Accept Negotiation Brand: Nihon Kohden
Product Category: Defibrillation Product Type: Spare Parts
Item Type: Circuit Board Item Name: Test Load Board
Part Number: UR-0251 Machine Application: TEC-7621C Defibrillator
Condition: Working In Good Condition Warranty: 90 Days
In Stock: Yes Color: Green
MOQ: One Piece
High Light:

Nihon Kohden Test Load Board

,

UR-0251 Test Load Board

,

6190-022656-S Test Load Board

Test Load Board UR-0251

Nihon Kohden Cardiolife TEC-7621C Defibrillator Test Load Board UR-0251 6190-022656-S

 

Brief Description

Test Load Board UR-0251 6190-022656-S for Nihon Kohden Cardiolife TEC-7621C Defibrillator

Test Load Board UR-0251 - is a small component on Nihon Kohden Cardiolife TEC-7621C Defibrillator. It is mainly a mechanical and circuit interface that connects test equipment and the device under test. Its main function is to test packaged integrated circuits. For TEC-7621C Defibrillator, a good yield test is very necessary. The Test Load Board can remove malfunctioning ICs to avoid subsequent failures of the equipment due to bad ICs.

 

 

► Specification

Brand Nihon Kohden
Product Category Defibrillation
Product Type Spare Parts
Item Type Circuit Board
Product Name Test Load Board
Part Number UR-0251
Machine Application TEC-7621C
Condition Working in Good Condition
Warranty 90 Days
Delivery Date 3 - 5 Working Days
Payment Method Western Union, Bank T/T, Paypal
Transpotation DHL, FedEx, UPS, TNT, EMS, By Air, etc.

 

 

Removing the Test Load Board
1. Remove the battery pack, memory card and lower case.

2. Remove the AC/DC unit.

3. Remove the main chassis and motherboard.

4. Remove the high voltage inductor.

5. Remove the high voltage capacitor and relay unit.

6. Remove the three M3 grub screws with spring washers and remove the high-voltage unit bracket.

7. Disconnect the CNA201 cable (to the main board) and speaker cable from the test load board.

8. Remove the two M3 grub screws with washers and spring washers from the test electrode plate.

9. Remove the two M3 grub screws, washers, and spring washers, and then remove the test load plate.

Nihon Kohden Cardiolife TEC-7621C Defibrillator Test Load Board UR-0251 6190-022656-S Medical Equipment Sapre Parts 0

Note: During the disassembly process, the high-voltage capacitor inside the Nihon Kohden Cardiolife TEC-7621C Defibrillator can store lethal energy. Always discharge the capacitor before touching any high-voltage component of the instrument (high-voltage capacitor, high-voltage inductor, relay unit, paddle socket, or paddle).

 

 
Condition

The Test Load Board UR-0251 for Nihon Kohden Cardiolife TEC-7621C Defibrillator is original used, but in good condition and with complete performance. Engineers will test it again for you before shipment to ensure the availability of the board. All products in our company have a 90-day warranty period. If any quality problems occur during this period that are not caused by other factors, you can contact us at any time for replacement or repair.

 
 

Detailed Photos

Nihon Kohden Cardiolife TEC-7621C Defibrillator Test Load Board UR-0251 6190-022656-S Medical Equipment Sapre Parts 1

Nihon Kohden Cardiolife TEC-7621C Defibrillator Test Load Board UR-0251 6190-022656-S Medical Equipment Sapre Parts 2

 

 

 

 

 

 

 

Thanks for your interest in Nihon Kohden Cardiolife TEC-7621C Defibrillator Test Load Board UR-0251 6190-022656-S, please feel free to contact me. Thank you for your time and wish you have a happy life.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Jasmine

Tel: 86-15180047496

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.