Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsDefibrillator Machine Parts

Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And SpO2 Module

Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And SpO2 Module

  • Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And  SpO2 Module
  • Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And  SpO2 Module
  • Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And  SpO2 Module
  • Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And  SpO2 Module
  • Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And  SpO2 Module
  • Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And  SpO2 Module
  • Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And  SpO2 Module
Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And  SpO2 Module
Product Details:
Brand Name: Primedic
Certification: CE/CB/ROSH
Model Number: M240 DM1 Defibrillator
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD
Packaging Details: Carton
Payment Terms: L/C, D/A, D/P, T/T
Contact Now
Detailed Product Description
Brand: Metrax Primedic M240 DM1 Defibrillator SpO2 Module Color: White
Category: Defibrillator SpO2 Module Wattanty: 90 Days
Packing Weight: 1.5kg Size: Uniform Size
Application Area: ICU,medical Equipment Condition: Used Or New
Estimated Ship Time: 3-5 Business Days In Stock: 300 Pieces
Specification: 18*16cm Used For: M240 DM1 Defibrillator
Net Weight: 0.6kg Shape: Standard
High Light:

Metrax Primedic DM1 Defibrillator SpO2 Module

,

Connecting Cable Defibrillator SpO2 Module

 

Metrax Primedic M240 DM1 Defibrillator SpO2 Module

 

Metrax Primedic M240 DM1 Defibrillator SpO2 Module,Includes Connecting Cable And SpO2 Module

 

►Quick Detail:

The SPO2 module is used for sampling examination or measuring the patient's blood oxygen saturation and pulse rate. For average blood oxygen saturation, the low-power module can send instantaneous blood oxygen saturation. Its detection speed is very efficient and the SPO2 module is compatible with all BCI probes. This module is suitable for measuring blood oxygen saturation and pulse rate in infants, newborns and adults.

 

 

►There are several inspection methods:

If there is a fault, there will be no blood oxygen waveform or blood oxygen value.

 

1. Replace the blood oxygen probe. If it doesn't work, the blood oxygen probe or blood oxygen extension cable may be faulty.
2. Check whether the blood oxygen probe model matches.
3. Check whether the red light of the blood oxygen probe is flashing. If it does not flash, the probe assembly is faulty.
4. If a blood oxygen "initialization error" alarm occurs, the blood oxygen module is faulty.
 

If the finger probe does not have a red light flashing, it may be a poor contact at the wire interface. It is recommended to check extension cords and socket connections. In areas with lower temperatures, try not to expose the patient's arms to avoid affecting the detection effect. Blood pressure measurement and blood oxygen measurement should not be performed on the same arm to avoid pressure on the arm and affect the measurement results. If the blood oxygen display waveform channel displays "No signal reception", it means there is a problem with the communication between the blood oxygen module and the host. Please close and then open again. If this prompt continues to appear, the blood oxygen module needs to be replaced.

 

If the SPO2 value is low or inaccurate, there are several checking methods:

1. First we have to ask whether this is a specific case or a general phenomenon. If it is a special situation, you can consider how to avoid it from the precautions of blood oxygen measurement, such as patient movement, poor microcirculation, hypothermia, too long time, etc.
2. If this is a common situation, please try to replace the blood oxygen probe. It may be caused by a faulty blood oxygen probe.
3. Check whether the blood oxygen extension cable is damaged.
Try to keep the patient as stable as possible. Once the blood oxygen value is lost due to hand movements, it is considered normal. If the blood oxygen extension cable is damaged, please replace it with a new one.

 

Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And  SpO2 Module 0

Metrax Primedic M240 DM1 Defibrillator SpO2 Module Includes Connecting Cable And  SpO2 Module 1

 

 

 

 

 

►features:

 

 

Brand Primedic
Type M240 DM1 Defibrillator SpO2 Module
Warranty period 90 Days
Shipping Date 3-5 Working Days
size 18*16cm
Storage temperature -20-70°c

 

 

About delivery:

 

We default to express delivery by DHL,Fedex, We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.

 

 

 

 

 

 

 

 


 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Mandy

Tel: +8615070124795

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.