China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Med-tronic |
Model Number: | 3200640-014 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator Display Bracket 3200640-014 | Brand: | Med-tronic |
---|---|---|---|
Part No: | 3200640-014 | Use For: | Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator |
MOQ: | One Piece | Warranty: | 90 Days |
Condition: | Work In Good | Color: | Grey |
Packaging: | Standard | Delivery Method: | DHL,UPS ,Fedex |
Highlight: | LP20 Defibrillator Machine Parts,Display Bracket Defibrillator Machine Parts,3200640-014 Defibrillator Display Bracket |
Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator Display Bracket 3200640-014
Display Removal
Note: Before starting disassembly, remove the following components: – Capital letters.
- Accommodation on the front
To remove the active A11 screen:
1. Disconnect the active display cable. (See picture) From the used A11 display follows:
– Gently pull on both sides of the locking tabs on the connector.
– Pull the cable out of the socket. (Leave the cable connected to the UI board)
2. Disconnect the W17 backlight converter cable from the user interface board.
3. Remove the four 4-40 × .312 screws from the display cover.
NOTICE: Remove the two grounding straps attached to the top two screws of the display assembly. Replace a broken or frayed floor assembly. 4. Remove the display bracket from the front bezel.
5. Check the condition of the following parts. Remove and replace any part that shows cracks, frayed wires, or damaged connectors.
A08 Backlight Inverter - To be removed. Disconnect the display power cable from CN2. Disconnect the backlight converter cable W17 from CN1. Remove the backlight converter from the display bracket. New display mounts are required as they come pre-installed with glue and foam.
W15 Active Display Cable: Remove Remove the cable from the A05 UI board to J36 (the cable was removed from the active display in step 1).
W17 Backlight Inverter Cable - For removal. Disconnect it from the A05 UI board at J37. Disconnect from backlight converter A08 (if not previously removed) at CN1.
Display support (47) — Replace if necessary after removing old parts. The display stand is pre-installed with self-adhesive inverter backlight board and active display foam.
Thermal pad (201) - To remove, remove the old pad from the inside edge of the upper case.
Product Name |
Med-tronic Physio-Control LIFEPAK 20(LP20) defibrillator display bracket 3200640-014
|
Brand | Med-tronic |
Part No |
3200640-014
|
Condition | Work in Good |
MOQ | One piece |
Warranty | 90 days |
RFQ
Our delivery time is 3-5 working days ,and it will take around 5-7 working days to arrive on your side for normal products .For special products such as battery ,it will take long to deliver .So please make purchase plans if urgent .
Contact us firstly ,then we will confirm product details and send proforma invoice to confirm .Orders will be shipped out after receiving payment .
I’m sorry we don’t have it .If you’re interested in our product ,feel free to send product pictures to get details
Thank you so much for your attention .If you're interested in Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator Display Bracket 3200640-014,feel free to contact us .Thank you .
Contact Person: Kiara
Tel: 8619854815217