China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Med-tronic |
Model Number: | 3200846-002 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator Capacitor Assembly 3200846-002 QR232EW196V21A 196uf 2300Vdc | Brand: | Med-tronic |
---|---|---|---|
Part No: | 3200846-002 | Use For: | Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator |
Type: | QR232EW196V21A 196uf 2300Vdc | MOQ: | One Piece |
Warranty: | 90 Days | Condition: | Work In Good |
Payment Terms: | Full Before Shipment | Delivery Method: | DHL,UPS ,Fedex |
Highlight: | 3200846-002 Defibrillator Capacitor Assembly,QR232EW196V21A Defibrillator Capacitor Assembly |
Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator Capacitor Assembly 3200846-002 QR232EW196V21A 196uf 2300Vdc
Energy Capacitor
The Energy Capacitor is a metallized film capacitor used to store energy. The energy capacitor stores the energy needed for pacing and defibrillation. The actual capacity of the energy capacitor is calculated during the defibrillation calibration process. The nominal value is 196 μF. When the device is turned off, current is drawn from the capacitor. The pacing and defibrillation therapy panel is powered by an induction coil. The power capacitor is mounted on the PCB with a capacitor holder. The power capacitor leads connect directly to the therapy board.
Error Description
9c2c | Capacitor voltage per pacing pulse too high | Replace the Therapy PCB. |
9c2d | Capacitor current per pacing pulse too high | Replace the Therapy PCB. |
9c32 | Capacitor voltage and predicted capacitor voltage mismatch |
1. Energy capacitor is not connected or is open. 2. Replace the Therapy PCB. |
9c3a | Energy capacitor overvoltage error | Replace the Therapy PCB. |
Capacitor Discharge Tool
ATTENTION! electric shock hazard. Rescue devices designed and labeled for non-biphasic defibrillators are not intended for use with biphasic defibrillators. The discharge of the power capacitor takes a few minutes.
Third-party devices for discharging two-phase capacitors are commercially available. Contact your support representative for more information.
An example configuration of a two-phase capacitor discharge device for discharging an energy storage capacitor is shown. The materials used in the example are:
■ 10 kΩ, 2 W resistor (ten 1 KΩ 2 W), high-voltage
■ 5 MΩ, 5 W resistor, high-voltage
■ Neon lamp, NE76, NE2, or NE2H
■ 8 AWG copper wire
■ Clear plastic tubing, capable of insulating 10 kV
■ 10 kV insulation
■ RTV, silicone rubber sealant
Warning! Electrocution hazard Defibrillators that are not designed and labeled for biphasic use are not suitable for use with biphasic pacemakers. Power capacitors take several minutes to discharge. The capacitor discharge tool is designed to discharge the energy storage capacitor before beginning any maintenance work on the internal components of the device. How to use a capacitor discharger:
1. Remove the battery.
2. Remove the top case.
3. Place the probe on the solder joint of the inductor and hold it. (see photo on next page)
4. Place another probe on the capacitor wiring connector. Keep both probes stationary.
5. Observe the neon light on the transmitter. When charged to around 90 volts, the fluorescent lamp lights up.
6. After the neon light turns off, hold the probe in the designated place for at least 30 seconds.