3200846-002 Defibrillator Capacitor Assembly QR232EW196V21A 196uf 2300Vdc

3200846-002 Defibrillator Capacitor Assembly QR232EW196V21A 196uf 2300Vdc

  • 3200846-002 Defibrillator Capacitor Assembly QR232EW196V21A 196uf 2300Vdc
  • 3200846-002 Defibrillator Capacitor Assembly QR232EW196V21A 196uf 2300Vdc
  • 3200846-002 Defibrillator Capacitor Assembly QR232EW196V21A 196uf 2300Vdc
  • 3200846-002 Defibrillator Capacitor Assembly QR232EW196V21A 196uf 2300Vdc
  • 3200846-002 Defibrillator Capacitor Assembly QR232EW196V21A 196uf 2300Vdc
  • 3200846-002 Defibrillator Capacitor Assembly QR232EW196V21A 196uf 2300Vdc
3200846-002 Defibrillator Capacitor Assembly QR232EW196V21A 196uf 2300Vdc
Product Details:
Brand Name: Med-tronic
Model Number: 3200846-002
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator Capacitor Assembly 3200846-002 QR232EW196V21A 196uf 2300Vdc Brand: Med-tronic
Part No: 3200846-002 Use For: Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator
Type: QR232EW196V21A 196uf 2300Vdc MOQ: One Piece
Warranty: 90 Days Condition: Work In Good
Payment Terms: Full Before Shipment Delivery Method: DHL,UPS ,Fedex
High Light:

3200846-002 Defibrillator Capacitor Assembly

,

QR232EW196V21A Defibrillator Capacitor Assembly

Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator Capacitor Assembly 3200846-002 QR232EW196V21A 196uf 2300Vdc

 

 

Energy Capacitor

 

The Energy Capacitor is a metallized film capacitor used to store energy. The energy capacitor stores the energy needed for pacing and defibrillation. The actual capacity of the energy capacitor is calculated during the defibrillation calibration process. The nominal value is 196 μF. When the device is turned off, current is drawn from the capacitor. The pacing and defibrillation therapy panel is powered by an induction coil. The power capacitor is mounted on the PCB with a capacitor holder. The power capacitor leads connect directly to the therapy board.

 

 

 

Error Description

 

     
9c2c Capacitor voltage per pacing pulse too high Replace the Therapy PCB.
9c2d Capacitor current per pacing pulse too high Replace the Therapy PCB.
9c32 Capacitor voltage and predicted capacitor voltage mismatch

1. Energy capacitor is not connected or is open.

2. Replace the Therapy PCB.

9c3a Energy capacitor overvoltage error Replace the Therapy PCB.

 

 

 

Capacitor Discharge Tool

 

ATTENTION! electric shock hazard. Rescue devices designed and labeled for non-biphasic defibrillators are not intended for use with biphasic defibrillators. The discharge of the power capacitor takes a few minutes.

 

Third-party devices for discharging two-phase capacitors are commercially available. Contact your support representative for more information.

 

An example configuration of a two-phase capacitor discharge device for discharging an energy storage capacitor is shown. The materials used in the example are:

 

■ 10 kΩ, 2 W resistor (ten 1 KΩ 2 W), high-voltage

■ 5 MΩ, 5 W resistor, high-voltage

■ Neon lamp, NE76, NE2, or NE2H

■ 8 AWG copper wire

■ Clear plastic tubing, capable of insulating 10 kV

■ 10 kV insulation

■ RTV, silicone rubber sealant

3200846-002 Defibrillator Capacitor Assembly QR232EW196V21A 196uf 2300Vdc 0

 

Warning! Electrocution hazard Defibrillators that are not designed and labeled for biphasic use are not suitable for use with biphasic pacemakers. Power capacitors take several minutes to discharge. The capacitor discharge tool is designed to discharge the energy storage capacitor before beginning any maintenance work on the internal components of the device. How to use a capacitor discharger:

 

1. Remove the battery.

2. Remove the top case.

3. Place the probe on the solder joint of the inductor and hold it. (see photo on next page)

4. Place another probe on the capacitor wiring connector. Keep both probes stationary.

5. Observe the neon light on the transmitter. When charged to around 90 volts, the fluorescent lamp lights up.

6. After the neon light turns off, hold the probe in the designated place for at least 30 seconds.

3200846-002 Defibrillator Capacitor Assembly QR232EW196V21A 196uf 2300Vdc 1

 

3200846-002 Defibrillator Capacitor Assembly QR232EW196V21A 196uf 2300Vdc 2

 

Thank you so much for your attention .If you're interested in  Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator Capacitor Assembly 3200846-002 QR232EW196V21A 196uf 2300Vdc,feel free to contact us .Thank you .

 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.