Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsDefibrillator Machine Parts

Med-tronic Physio Control LIFEPAK 20 LP20 Therapy And Pacing Board 3202259 100-002-421F BMP006722-0067 21330-001560

Med-tronic Physio Control LIFEPAK 20 LP20 Therapy And Pacing Board 3202259 100-002-421F BMP006722-0067 21330-001560

  • Med-tronic Physio Control LIFEPAK 20 LP20 Therapy And Pacing Board 3202259 100-002-421F BMP006722-0067 21330-001560
  • Med-tronic Physio Control LIFEPAK 20 LP20 Therapy And Pacing Board 3202259 100-002-421F BMP006722-0067 21330-001560
  • Med-tronic Physio Control LIFEPAK 20 LP20 Therapy And Pacing Board 3202259 100-002-421F BMP006722-0067 21330-001560
  • Med-tronic Physio Control LIFEPAK 20 LP20 Therapy And Pacing Board 3202259 100-002-421F BMP006722-0067 21330-001560
Med-tronic Physio Control LIFEPAK 20 LP20 Therapy And Pacing Board 3202259 100-002-421F BMP006722-0067 21330-001560
Product Details:
Brand Name: Med-tronic
Model Number: Lifepak LP20
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Med-tronic Lifepak LP20 Defibrillator Therapy Board And Pacing Board Type: Lifepak LP20
Application: Medical Equipment,ICU,hospital Device Warranty: 90days
Color: White Key Words: Therapy Board And Pacing Board
Language: Multiple Languages Superiority: Specialized Engineers With 12 Years Of Experience
Sale Protection: If We Find Non-human Damage, We Will Be Free For You To Repair Or Returned Product State: Run Well
AC Input Voltage Rate: 110V—240v Power Supply Source: Electric
Inventory: In Stock Method Of Transport: Expressage
MOQ: 1pcs
High Light:

3202259 Pacing Board

,

21330-001560 Pacing Board

 

Med-tronic Physio-Control LIFEPAK 20 LP20 Therapy Board and Pacing board 3202259 100-002-421F BMP006722-0067 21330-001560

 

 

 

► Brief Introduction

The Therapy PCB controls the pacing and defibrillation therapy features. The primary communication between the Therapy PCB and the remainder of the device is through the data bus. A microprocessor and digital memory make up the central processing unit (CPU) that manages communication with the System Control PCB.

 

 

 

Major subsystems

Power Supplies — The Therapy PCB uses SW_VBatt (switched battery voltage) from the Power Module to originate five power supply voltages for use throughout the PCB as follows:

  • +5 V logic power to drive the CPU microprocessor and memory
  • ±15 V analog power for the pacing and therapy drive circuit
  • Patient-isolated 5 V analog power for the pacing and therapy circuits
  • Patient-isolated 15 V analog power for the pacing and therapy circuits
  • Patient-isolated 30 V analog power for the pacing and therapy circuits

Power Switch — A power switch is a control circuit that detects the ON button selection from the User Interface PCB or a timer event from the System Control PCB to power up the device. This portion of the Therapy PCB is powered at all times, with very low quiescent current draw. When a power-on request is detected, this circuit switches VBatt (battery and/or ac converted dc power) provided by thePower Module to the remaining PCBs in the device. Low Battery (Battery Fail) is detected and a discrete signal is broadcast to other PCBs if battery voltage falls rapidly or reaches the point where normal operation is no longer feasible.

 

Cap Charger — The cap charger is a high-voltage, patient-isolated circuit that charges the Energy Capacitor to the correct voltage for biphasic defibrillation (2 to 360 joules). Control is provided by the CPU, and capacitor voltage is provided back to the CPU for feedback. The cap charger is designed to nominally provide maximum charge rates and to automatically scale back to slower charge rates when low battery voltage is detected.

 

Pacer Power Supply — The pacer power supply is a patient-isolated circuit that charges the Energy Capacitor up to the correct voltage for pacing. Control is provided by the CPU, and voltage regulation is maintained locally within the pacer supply. Capacitor voltage is provided back to the CPU for control through the cap charger circuitry

 

H-Bridge — The H-Bridge is a patient-isolated circuit that creates the biphasic defibrillation waveform. A combination of silicon controlled rectifiers (SCR) and insulated gate bipolar transistors (IGBT) are used to place a positive-oriented defibrillation pulse across the patient load, followed immediately by a negative-oriented defibrillation pulse. The defibrillation pulse is delivered through the relay and Therapy Connector assembly to the external therapy cable on the outside of the device.

 

Pacer — The pacer is a patient-isolated circuit that creates the pacing waveform. A portion of the H-Bridge circuitry is used to support the pacer by providing energy from the Defibrillation Capacitor. A current drive is used to control the amount of current provided to the patient during pacing.

 

Relay — The relay provides patient isolation from the pacing and defibrillation circuitry when not in use. The relay is closed when the pacing current is set above zero and stays closed until the pacing current is set back to zero.

 

 

 

Specification

Type Lithium-ion, rechargeable
Voltage Typical: 11.1 V
Operating range: 9.0 V – 12.6 V
Capacity 2.4 Ah
Operating Temperature 0° to 45°C (32° to 113°F)
Storage Temperature -20° to 60°C (-4° to 140°F) for up to 1 month
Relative Humidity 5 to 95% non-condensing

 

Med-tronic Physio Control LIFEPAK 20 LP20 Therapy And Pacing Board 3202259 100-002-421F BMP006722-0067 21330-001560 0

 

 

 

Thank you for your time and interest in Med-tronic Physio-Control LIFEPAK 20 LP20 Therapy Board and Pacing board 3202259 100-002-421F BMP006722-0067 21330-001560. If you want to explore more details please let us know.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.