Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

Mindray M8 M9 TE7 Ultrasound SV300 Ventilator Rechargeable Li-ion Battery LI24I002A

Mindray M8 M9 TE7 Ultrasound SV300 Ventilator Rechargeable Li-ion Battery LI24I002A

  • Mindray M8 M9 TE7 Ultrasound SV300 Ventilator Rechargeable Li-ion Battery LI24I002A
  • Mindray M8 M9 TE7 Ultrasound SV300 Ventilator Rechargeable Li-ion Battery LI24I002A
  • Mindray M8 M9 TE7 Ultrasound SV300 Ventilator Rechargeable Li-ion Battery LI24I002A
  • Mindray M8 M9 TE7 Ultrasound SV300 Ventilator Rechargeable Li-ion Battery LI24I002A
Mindray M8 M9 TE7 Ultrasound SV300 Ventilator Rechargeable Li-ion Battery LI24I002A
Product Details:
Brand Name: Mindray Battery
Model Number: LI24I002A
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Mindray SV300 Battery Type: Rechargeable Li-ion Battery
Application: Medical Equipment,ICU,hospital Device Warranty: 90days
Superiority: Original Product State: In Good Condition
PARAMETERS: ECG,TEMP,RESP,NIBP,SPO2,etc Product Features: Pragmatic,Professional, Reliable
Power Supply Source: Electricity MEANS OF TRANSPORT: Express Delivery
Inventory Status: Sufficient Inventory Company Objectives: Sincere And Trustworthy
Voltage Rating: 110V—240v Minimum Purchasing Quantity: 1pcs
PN: LI24I002A

 

Mindray M8 M9 TE7 Ultrasound SV300 Ventilator Rechargeable Li-ion Battery LI24I002A

 

 

► Brief Introduction

The ventilator is designed to operate on battery power whenever power supply becomes interrupted. When the ventilator is connected to the external power source, the batteries are charged regardless of whether the ventilator is currently on or not. In case of power failure, the ventilator will automatically be powered by the internal batteries. When external power source is restored within the specified time, power supply is switched from battery to external power supply automatically to ensure continuous system use.

 

 

 

Battery Performance Checking

Check battery performance once every six months. Checking battery performance is also required before ventilator repair is carried out or when battery is doubted to be the source for ventilator failure. Battery performance may degrade over time.

Follow these steps to check battery performance:

1. Disconnect the patient from the ventilator and shut down the ventilator.

2. Connect the ventilator to the external power source and charge the batteries uninterruptedly for at least 10 hours.

3. Disconnect the external power source. Allow the ventilator to operate on battery power until the ventilator shuts off.

4. The running time of the battery reflects its performance.

If the running time of the battery is noticeably shorter than that stated in the specifications, replace the battery or contact the service personnel.

 

 

 

► Battery in Use

1. Connect the ventilator to AC power and push the Mindray M8 M9 TE7 Ultrasound SV300 Ventilator Rechargeable Li-ion Battery LI24I002A 0 hardkey to switch on.

2. Disconnect the AC power after the system starts up.

3. Verify that the [Battery in Use] alarm is activated and the ventilator is powered by batteries.

4. Reconnect the AC power.

5. Verify that the alarm resets and the ventilator is again powered by AC.

Mindray M8 M9 TE7 Ultrasound SV300 Ventilator Rechargeable Li-ion Battery LI24I002A 1

 

 

Remove the Lithium Battery

 

 

1. Lay down the machine. Remove the 4 M3X8 self-locking screws on the main unit battery compartment door from the bottom to remove the battery compartment door.

Mindray M8 M9 TE7 Ultrasound SV300 Ventilator Rechargeable Li-ion Battery LI24I002A 2

 

2. Pull out the slice on the battery to remove the lithium battery.

Mindray M8 M9 TE7 Ultrasound SV300 Ventilator Rechargeable Li-ion Battery LI24I002A 3

 

 

 

► Specification

Battery type Lithium-ion battery
Rated battery voltage 14.8 VDC
Battery capacity 5800 mAh for a single battery
Overcurrent protection 8.2 ± 5 %A
Battery run time: 180 min (powered by one new fully-charged battery in standard working condition);
360 min (powered by two new fully-charged batteries in standard working condition).

 

 

 

► Shipment Arrangements

As for delivery time, we will try our best to process the orders and ship them out as soon as possible. Please be patient and keep contact with us. Generally speaking, most orders will be shipped in 3 to 5 working days and can arrive on time. However, during the busy days the shipment may be delayed over 5 working days. If you are in urgent need of your item, please be sure to confirm with us before placing your orders. To make sure the business goes smoothly, please pay special attention to it and carefully arrange your time of placing orders according to your personal needs. If your order is taking longer than expected or you want to make it clear that when it will arrive, please feel free to contact us. We are always here to help you out.

 

 

 

 

"Quality assurance" is our eternal pursuit and promise. Don't be hesitant to contact us! Welcome to place your orders. Thank you for your time and interest in Mindray M8 M9 TE7 Ultrasound SV300 Ventilator Rechargeable Li-ion Battery LI24I002A .

 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.