Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator

Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator

  • Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator
  • Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator
  • Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator
  • Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator
Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator
Product Details:
Brand Name: Hamilton
Model Number: 161186
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Hamilton Expiratory Valve Type: Expiratory Valve
Application: Philip Respironics V60 Ventilator Warranty: 90 Days
PN: 161186 Product Situation: In Good Order
Mode Of Transport: Expressage Product Type: Rechargeable Lithium Battery
Packaging Unit: 1 Per Case
Highlight:

Membrane Hamilton Expiratory Valve

,

REF 161186 Hamilton Expiratory Valve

,

Cover Hamilton Expiratory Valve

 

Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator machine

 

 

 

 

► Brief Introduction

The HAMILTON Neonatal Expiratory Valve Set with Cover and Membrane is a medical device used in neonatal ventilation to control the flow of gases during expiration. It includes a valve, cover, and membrane that work together to regulate the release of exhaled air from the patient's lungs. This device is essential for maintaining appropriate levels of carbon dioxide in the blood and ensuring efficient gas exchange in newborn babies who require respiratory support.

 

 

► How to use

Open the packaging of the HAMILTON Neonatal Expiratory Valve Set and remove the contents.

Insert the membrane into the cover by aligning the holes in the center of the membrane with the corresponding pegs on the cover. The membrane should be securely placed in the cover.

Connect the assembled cover and membrane to the expiratory valve on the neonatal breathing circuit. Ensure that it is securely attached to prevent any leaks during expiration.

Once the valve set is properly connected and in place, turn on the ventilator and set the appropriate settings for the neonatal patient.

Monitor the patient's breathing and adjust the ventilator settings as needed to provide the necessary support.

When the neonatal patient is no longer in need of ventilator support, disconnect the HAMILTON Neonatal Expiratory Valve Set and dispose of it according to the appropriate medical waste disposal guidelines.

Keep records of the usage of the valve set and replace it with a new one as needed to maintain proper and safe respiratory support for neonatal patients.

 

 

To assemble/install the expiratory valve set

 

1. Remove the safety cover.

2. Ensure the membrane is properly aligned with the expiratory valve housing and the metal plate faces up (1).

3. Position the expiratory valve set in the expiratory port (2) and twist the locking ring clockwise until it locks into place (3).

► Brief Introduction

The HAMILTON Neonatal Expiratory Valve Set with Cover and Membrane is a medical device used in neonatal ventilation to control the flow of gases during expiration. It includes a valve, cover, and membrane that work together to regulate the release of exhaled air from the patient's lungs. This device is essential for maintaining appropriate levels of carbon dioxide in the blood and ensuring efficient gas exchange in newborn babies who require respiratory support.

 

 

 

► How to use

Open the packaging of the HAMILTON Neonatal Expiratory Valve Set and remove the contents.

Insert the membrane into the cover by aligning the holes in the center of the membrane with the corresponding pegs on the cover. The membrane should be securely placed in the cover.

Connect the assembled cover and membrane to the expiratory valve on the neonatal breathing circuit. Ensure that it is securely attached to prevent any leaks during expiration.

Once the valve set is properly connected and in place, turn on the ventilator and set the appropriate settings for the neonatal patient.

Monitor the patient's breathing and adjust the ventilator settings as needed to provide the necessary support.

When the neonatal patient is no longer in need of ventilator support, disconnect the HAMILTON Neonatal Expiratory Valve Set and dispose of it according to the appropriate medical waste disposal guidelines.

Keep records of the usage of the valve set and replace it with a new one as needed to maintain proper and safe respiratory support for neonatal patients.

 

 

 

To assemble/install the expiratory valve set

1. Remove the safety cover.

2. Ensure the membrane is properly aligned with the expiratory valve housing and the metal plate faces up (1).

3. Position the expiratory valve set in the expiratory port (2) and twist the locking ring clockwise until it locks into place (3).

Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator 0

 

 

 

► To disassemble and remove the expiratory valve set

1. Remove the expiratory valve set from the expiratory port on the ventilator.

2. Holding the expiratory valve housing, remove the silicone membrane (1) by lifting it up.

 

 

 

► Specification

Patient data / Component Adult Pediatric
Patient height (cm) > 130 30 to 150
IBW (kg) > 30 3 to 48
Tracheal tube ID (mm) > 4  
Breathing circuit limb ID (mm) 15 to 22 10 to 22
Flow sensor Adult/Ped Adult/Ped
CO2 airway adapter Adult/Ped Adult/Ped

 

 

 


 

 

Thank you for your time and interest in Hamilton Pediatric & Adult Expiratory Valve Set with cover and membrane REF 161186 for C1 T1 T1 Military MR1 Ventilator .

"Quality assurance" is our eternal pursuit and promise. Don't be hesitant to contact us! Welcome to place your orders.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Bella Liu

Tel: +8618879075074

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.