HAMILTON Neonatal Expiratory Valve Set with Cover and Membrane for C1 T1 MR1 Ventilator Machine REF 161189
► Brief Introduction
The HAMILTON Neonatal Expiratory Valve Set with Cover and Membrane is a medical device used in neonatal ventilation to control the flow of gases during expiration. It includes a valve, cover, and membrane that work together to regulate the release of exhaled air from the patient's lungs. This device is essential for maintaining appropriate levels of carbon dioxide in the blood and ensuring efficient gas exchange in newborn babies who require respiratory support.
► How to use
► To use an adult/pediatric flow sensor with a neonatal/pediatric breathing circuit
1. Verify that the Adult/Ped patient group is selected.
2. Verify that the patient IBW is below 20 kg.
3. Set up the ventilator for adult/pediatric ventilation with the adult/pediatric flow sensor, but connect a neonatal/pediatric breathing circuit.
4. Perform the Tightness test, calibrate the flow sensor, and perform other preoperational checks.
5. Connect the patient.
6. Start ventilation.
► To assemble/install the expiratory valve set
1. Remove the safety cover.
2. Ensure the membrane is properly aligned with the expiratory valve housing and the metal plate faces up (1).
3. Position the expiratory valve set in the expiratory port (2) and twist the locking ring clockwise until it locks into place (3).
► To disassemble and remove the expiratory valve set
1. Remove the expiratory valve set from the expiratory port on the ventilator.
2. Holding the expiratory valve housing, remove the silicone membrane (1) by lifting it up.
► Specification
Patient group/component | Specification |
Patient group | Neonatal |
Weight (kg) | 0.2 to 30 |
Tracheal tube ID (mm) | ≤ 4 |
Breathing circuit tube ID (mm) | 10 to 12 |
Flow sensor | Neonatal |
Pressure line | Neonatal |
CO2 airway adapter | Neonatal |
► Product Use
We specialize in the sales and maintenance of various medical equipment and accessories. Our main brands are Philip, Mindray, GE, Goldway, NIHON KOHDEN, etc. Since the establishment of the company, we have explored and developed in this industry for many years. Our products are mainly used for medical equipment in hospitals or clinics. We sell complete machines, spare parts, and also develop product maintenance services. Our main products are patient monitors, defibrillators, ECG machines and various module accessories. If you want to know more detailed information about our products, welcome to contact us. We will give you a detailed introduction.