REF 1113780 External Battery For Philip Respironics Trilogy 100 Ventilator

  • REF 1113780 External Battery For Philip Respironics Trilogy 100 Ventilator
  • REF 1113780 External Battery For Philip Respironics Trilogy 100 Ventilator
  • REF 1113780 External Battery For Philip Respironics Trilogy 100 Ventilator
  • REF 1113780 External Battery For Philip Respironics Trilogy 100 Ventilator
REF 1113780 External Battery For Philip Respironics Trilogy 100 Ventilator
Product Details:
Brand Name: PHILIP
Model Number: 1113780
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: Battery REF 1113780 For Philip Respironics Trilogy 100 Ventilator External Brand: Philip
Part No: 1113780 Application: Philip Respironics Trilogy 100 Ventilator
MOQ: One Piece Warrant: 90 Days
Condition: Original New Voltage: 14.8V ,4440mAh,66Wh
Origin: China Packaging: Standard
High Light:

REF 1113780 External Battery

,

External Battery For Philip Respironics

 

 

Philip Respironics Trilogy 100 Ventilator External battery REF1113780

 

 

Battery life

Internal and removable batteries wear out with use. (hours or full discharge cycles) Battery capacity and life will decrease with higher operating temperatures.

 

 

Low battery alarm

 

Low battery alarm occurs when the last available battery is low or almost dead. This alarm occurs in two stages. When approximately 20 minutes of battery life remains, a medium priority notification will be generated. and the device will continue to work. If no action is taken and the battery is still charged, the alarm will become a high priority alarm. When there is approximately 10 minutes of battery life remaining

 

 

Replaceable alarm with removable battery.

 

The removable battery replacement alert occurs when the removable battery is nearing the end of its useful life or a fault is detected in the removable battery that prevents it from being charged or discharged. The warning occurs in several stages. From least to most important The device continues to operate when the alarm is of low priority. If the alarm is reset without removing the battery, alerts are created again each time. hours until the removable battery is removed. The device continues to operate. Does not use removable battery. and the power will switch to the next available power supply. If the alarm is a high priority alarm

 

External Battery

 

The respirator can operate from a 12V DC deep cycle (lead-acid) marine battery using the Philip Respironics Trilogy external battery cable. This cable is pre-wired and properly terminated to ensure safe connection of the external battery to a respirator safely. Battery life depends on battery characteristics and device usage.

 

Due to many factors including battery chemistry. Battery life and usage characteristics Therefore, the external battery capacity displayed on the device screen is only an estimate of the actual remaining capacity.

 

 

Please refer to the instructions included with the Philip Respironics Trilogy external battery cable for detailed information on how to operate your device with an external battery.

 

 

Internal Battery

 

This device has an internal battery that can be used as a backup power source. It is intended to be used for a short period of time. when switching from an external power source to an emergency situation or in a short period of time When the user must move The operating time of an internally powered fan depends on many factors, such as device settings. Battery charge level and battery condition or age Once fully charged, new batteries will be able to power the ventilator for approximately three hours under typical patient conditions.

 

Every time the fan is connected to the mains, it automatically recharges the internal battery. A completely discharged internal battery reaches 80% charge in 8 hours when charged at an ambient temperature of approximately 23°C (73°F).

 

 

Specification of Philip Respironics Trilogy 100 Ventilator External battery REF1113780

 

Product Name Philip Respironics Trilogy 100 Ventilator External battery REF1113780
Brand Philip
Application Philip Respironics Trilogy 100 Ventilator
Part No 1113780
Condition Original new
MOQ One piece
Warranty 90 days
Voltage 14.8V ,4440mAh,66Wh
Origin China

 

 

 

 

REF 1113780 External Battery For Philip Respironics Trilogy 100 Ventilator 0

 

 

 

Thank you so much for your attention .If you're interested in Philip Respironics Trilogy 100 Ventilator External battery REF1113780 ,feel free to contact us .Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.