Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

Newport Medical HT-70 Plus Ventilator Lithium Ion Battery BAT3271A

Newport Medical HT-70 Plus Ventilator Lithium Ion Battery BAT3271A

  • Newport Medical HT-70 Plus Ventilator Lithium Ion Battery BAT3271A
  • Newport Medical HT-70 Plus Ventilator Lithium Ion Battery BAT3271A
  • Newport Medical HT-70 Plus Ventilator Lithium Ion Battery BAT3271A
  • Newport Medical HT-70 Plus Ventilator Lithium Ion Battery BAT3271A
Newport Medical HT-70 Plus Ventilator Lithium Ion Battery BAT3271A
Product Details:
Brand Name: Newport
Model Number: BAT3271A
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: BAT3271A Newport Medical HT-70 Plus Ventilator Lithium Ion Battery Brand: Newport
Part No: BAT3271A Application: Newport Medical HT-70 Plus Ventilator
Battery Type: Lithium Ion Voltage: 14.4v 85Wh
Dater Flash Ver: 10.0 Condition: Original New
MOQ: One Piece Warranty: 90 Days
High Light:

Ventilator Lithium Ion Battery

,

BAT3271A Ventilator Lithium Ion Battery

 

BAT3271A Newport Medical HT-70 Plus Ventilator Lithium Ion Battery

 

Newport Medical HT-70 Plus Battery BAT3271A

 

The Newport™ HT70 Ventilator's internal dual battery system consists of two internally independent but coordinated lithium-ion batteries: the Power Pac located on the rear of the ventilator and the auxiliary backup battery inside the ventilator. When new and fully charged, the internal dual battery system provides up to 10 hours of battery life in standard configuration*. The system provides continuous support during transportation, daily activities or power outages.

Proper care and maintenance of the internal dual battery system will ensure maximum lifespan.

 

 

The Power Pac Integrated Battery (BAT3271A) is a removable “hot-swappable” battery. It slips on easily and can be replaced with a fully charged battery without disrupting ventilation. Charge the Power Pac for at least 3 hours to reach 100% charge. If the battery is not completely discharged, charging time may be reduced.

 

 

When the blower is used in transportation applications, ensure the Power Pac battery is fully charged before use. We strongly recommend carrying an additional, fully charged Power Pac with you during transportation or outdoor applications. The Power Pac can be charged independently of the fan and an LED on the bottom edge indicates the charging status. To check the charging status, press the button on the bottom edge of the Power Pac (green = charge level approximately 90% or more, yellow = incomplete charge, red = empty battery). Always connect the Power Pac to the fan and turn it on to check the actual battery percentage (displayed on the message screen).

 

 

Conditions that affect the battery.

 

Usage Time Each of the items listed below affects the life of the built-in dual battery system:

• Energy saving

• pressure

• Respiratory rate

• PEP activated or deactivated

• Duration/use

 

The most important setting that affects battery life is Battery Saver. If you turn off the power saving feature, battery life will be reduced by approximately 30%. When power saving mode is enabled, the screen goes into sleep (blank) mode to save power. An active alarm will temporarily interrupt power saving mode and the screen will activate. Power saving functions will resume 2 minutes after the alarm condition resolves. Maximum blood pressure and respiratory rate also affect battery life. If the maximum pressure continues to exceed 30 cmH2O and the respiratory rate is greater than 20, a loss of battery life of 15-25% is expected. Using PEP means that a bias current will be used. Since this means the dual piston will operate during inhalation and exhalation, battery life will be shorter when PEEP is activated. As the battery ages with use, the length of time the fan can operate on battery power from a fully charged state will decrease. If battery life is insufficient, replace the Power Pac battery every 24 months or sooner. If the fan is operating on a Power Pac battery for an extended period of time, ensure the battery is fully charged before use.

 

Battery Specification

 

Battery Type Lithium Ion Battery
Voltage 14.4v 85Wh
Dater Flash Ver 10.0
Use for Newport Medical HT-70 Plus Ventilator

 

Newport Medical HT-70 Plus Ventilator Lithium Ion Battery BAT3271A 0

 

Thank you so much for your attention .If you're interested in BAT3271A Newport Medical HT-70 Plus Ventilator Lithium Ion Battery ,feel free to contact us .Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.