10086042 71MR1865-3 Rechargeable Lithium Ion Battery For Covidien Puritan Bennett 980 PB980 Ventilator

10086042 71MR1865-3 Rechargeable Lithium Ion Battery For Covidien Puritan Bennett 980 PB980 Ventilator

  • 10086042 71MR1865-3 Rechargeable Lithium Ion Battery For Covidien Puritan Bennett 980 PB980 Ventilator
  • 10086042 71MR1865-3 Rechargeable Lithium Ion Battery For Covidien Puritan Bennett 980 PB980 Ventilator
  • 10086042 71MR1865-3 Rechargeable Lithium Ion Battery For Covidien Puritan Bennett 980 PB980 Ventilator
  • 10086042 71MR1865-3 Rechargeable Lithium Ion Battery For Covidien Puritan Bennett 980 PB980 Ventilator
10086042 71MR1865-3 Rechargeable Lithium Ion Battery For Covidien Puritan Bennett 980 PB980 Ventilator
Product Details:
Brand Name: Covidien
Model Number: Puritan Bennett 980
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Covidien Type: Puritan Bennett 980
Application: Medical Equipment,ICU,hospital Device Warranty: 90days
Temperature Range Operating: 10°C To 40°C (50°F To 104°F) Temperature Range Storage: -20°C To 70°C (-4 °F To 158°F)
Atmospheric Pressure Operating: 70 KPa To 106 KPa (10.15 Psi To 15.37 Psi) Atmospheric Pressure Storage: 50 KPa To 106 KPa (7.25 Psi To 15.37 Psi)
Altitude Range Operating: -411.5 M To 3,048 M (-1,350 Ft To 10,000 Ft) Altitude Range Storage: 6,096 M Max (20,000 Ft Max)
High Light:

10086042 Rechargeable Lithium Ion Battery

,

71MR1865-3 Lithium Ion Battery

 

Covidien Rechargeable Lithium Ion Battery 10086042 71MR1865-3 for Covidien Puritan Bennett 980 PB980 Ventilator Accessories 25.9V

 

 

 

► Brief Introduction

The ventilator’s primary battery is located in the rearward battery receptacle on the right side of the BDU. The compressor’s primary battery is located in the rearward battery receptacle in the compressor base.The primary battery may be “hot swapped,” that is it can be replaced while the ventilator is operating.

 

 

 

To install or replace the primary battery in the BDU or compressor

1. With the battery not installed in the ventilator, or if the ventilator is turned off and not connected to AC power, check the charge level by pressing the charge level button on the battery and verifying the charge level LEDs illuminate.For the location of the charge level button. Five green LED segments illuminate, indicating ≥ 90% battery capacity. From bottom to top, the first LED indicates ≥ 10% capacity, the second LED indicates ≥ 25% capacity, the third LED indicates ≥ 50% capacity, and the fourth LED indicates ≥ 75% capacity. An illuminated red LED at the top of the battery indicates a battery fault. If no LEDs illuminate it means there is < 10% battery capacity remaining.

2. If the charge level is sufficient, orient the battery face the front of the ventilator and locate the battery compartments on the right side of the appropriate module. The receptacle towards the rear of the ventilator houses the primary battery while the receptacle towards the front of the ventilator houses the extended battery.

3. The primary battery is fastened in place with a thumbscrew. Loosen the thumbscrew approximately four to five turns to allow battery installation.

4. Insert the battery and push into its receptacle all the way until it clicks, indicating it is latched. The battery will only fit into the slot one way.

5. Tighten the thumbscrew to secure the battery and prevent the primary battery from being removed.

 

 

 

 

Battery Testing

Push the battery charge level button located on the battery. A series of LEDs illuminates, indicating the charge level of the battery. When the bottom LED is illuminated, there is ≥ 10% of full battery capacity. The next LED illuminates when there is ≥ 25% capacity. the third lamp illuminates when there is ≥ 50% capacity available. The fourth LED illuminates when there is ≥ 75% capacity, and when the top LED is illuminated, it represents ≥ 90% capacity.

 

 

 

Overview

10086042 71MR1865-3 Rechargeable Lithium Ion Battery For Covidien Puritan Bennett 980 PB980 Ventilator 0

1 White battery in-use LED
2 Red battery fault indicator
3 Green charge status LEDs
4 Charge level button

 

 

 

 

Thank you for your time! If you are interested in Covidien Rechargeable Lithium Ion Battery 10086042 71MR1865-3 for Covidien Puritan Bennett 980 PB980 Ventilator , please let us know. Welcome to place your orders.

Thank you for your time and interest.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.