MAJ-855 Olympus Auxiliary Water Tube EVIS180/160 Endoscopes With Auxiliary Water Channel

MAJ-855 Olympus Auxiliary Water Tube EVIS180/160 Endoscopes With Auxiliary Water Channel

  • MAJ-855  Olympus Auxiliary Water Tube EVIS180/160 Endoscopes With Auxiliary Water Channel
  • MAJ-855  Olympus Auxiliary Water Tube EVIS180/160 Endoscopes With Auxiliary Water Channel
  • MAJ-855  Olympus Auxiliary Water Tube EVIS180/160 Endoscopes With Auxiliary Water Channel
  • MAJ-855  Olympus Auxiliary Water Tube EVIS180/160 Endoscopes With Auxiliary Water Channel
  • MAJ-855  Olympus Auxiliary Water Tube EVIS180/160 Endoscopes With Auxiliary Water Channel
MAJ-855  Olympus Auxiliary Water Tube EVIS180/160 Endoscopes With Auxiliary Water Channel
Product Details:
Brand Name: Olympus
Model Number: MAJ-855
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: MAJ-855 Olympus Auxiliary Water Tube Applicated EVIS180/160 Endoscopes With An Auxiliary Water Channel Brand: Olympus
Part No: MAJ-855 Origin: Japan
Application: EVIS180/160 Endoscopes With An Auxiliary Water Channel Intended Use: Intended Use
Reprocessing Frequency For MAJ-855/MH-974: After Each Patient Exam MOQ: One Piece
Warranty: 90 Days Condition: New
High Light:

MAJ-855 Olympus Auxiliary Water Tube

,

EVIS180/160 Auxiliary Water Tube

MAJ-855 Olympus Auxiliary Water Tube Applicated EVIS180/160 Endoscopes With An Auxiliary Water Channel

The MAJ-855 auxiliary water tube must be reconditioned each time it is used during an endoscopic procedure, regardless of whether the auxiliary water supply function is used during the procedure.

 

The MAJ-855 Auxiliary Water Hose is shown below and can be clearly identified by the model name (“MAJ-855”) engraved on the green Luer connector. The connector contains a one-way valve that prevents backflow of fluid through the tubing and prevents water from flowing freely from the other end of the tubing (the metal connector) when the syringe or pump is disconnected from the green Luer connector.

 

MAJ-855  Olympus Auxiliary Water Tube EVIS180/160 Endoscopes With Auxiliary Water Channel 0

 

Additional water hose MAJ-855 is part of the standard set of all new endoscopes of the OLYMPUS 160 and 180 series with an additional water hose. The following endoscopes of the OLYMPUS 160/180 series are equipped with auxiliary water channels.

 

 

The auxiliary water line MAJ-855 is used to flow sterile water through the auxiliary water channel to flush the endoscopic field during patient examination. Sterile mucosal cleansing water can be delivered manually using a syringe or automatically using an irrigation pump.

 

 

The following figure shows the connection for manual flushing of sterile water through the auxiliary water channel using a syringe. The irrigation water flows through the auxiliary channel (a small special tube in the endoscope) and emerges in a strong stream from the distal end of the instrument.

 

 

MAJ-855  Olympus Auxiliary Water Tube EVIS180/160 Endoscopes With Auxiliary Water Channel 1

 

Or, as shown in the figure below, the MAJ-855 can be connected to the tubing of an irrigation pump to automatically flow sterile water through the auxiliary channel of the endoscope for mucosal irrigation.

 

MAJ-855  Olympus Auxiliary Water Tube EVIS180/160 Endoscopes With Auxiliary Water Channel 2

 

MAJ-855 water refill lines must be disinfected before first use and after each use (i.e. after each patient examination). Whenever the MAJ-855 auxiliary water supply is connected to an endoscope for clinical use, regardless of whether the auxiliary water supply function is used during the procedure, it must be reprocessed before it can be used again on other patients. The green MAJ-855 one-way valve with Luer connector is important for the safe and efficient use of this accessory. The one-way valve prevents backflow of fluid through the tubing and prevents water from flowing freely from the other end of the tubing (the metal connector) when the syringe or pump is disconnected from the green Luer connector. Do not modify this hose or replace its connections. Connectors should not be removed for reprocessing.

 

 

 

Specification

 

Application EVIS180/160 endoscopes with an auxiliary water channel
Intended use

Auxiliary water flushing using a syringe or flushing pump

 

Reprocessing the auxiliary water channel

Reprocessing frequency for MAJ-855/MH-974 After each patient exam

 

 

 

MAJ-855  Olympus Auxiliary Water Tube EVIS180/160 Endoscopes With Auxiliary Water Channel 3

 

Thank you for your attention .If you're interested in MAJ-855 Olympus Auxiliary Water Tube Applicated EVIS180/160 Endoscopes With An Auxiliary Water Channel ,feel free to contact us .Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.