Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

Biolight BLT Reusable Neonatal Infant Spo2 Sensor PN 15-100-0015 REF A1418-SW203MU For M8000 M9000 M9500

Biolight BLT Reusable Neonatal Infant Spo2 Sensor PN 15-100-0015 REF A1418-SW203MU For M8000 M9000 M9500

  • Biolight BLT Reusable Neonatal Infant Spo2 Sensor PN 15-100-0015 REF A1418-SW203MU For M8000 M9000 M9500
  • Biolight BLT Reusable Neonatal Infant Spo2 Sensor PN 15-100-0015 REF A1418-SW203MU For M8000 M9000 M9500
  • Biolight BLT Reusable Neonatal Infant Spo2 Sensor PN 15-100-0015 REF A1418-SW203MU For M8000 M9000 M9500
  • Biolight BLT Reusable Neonatal Infant Spo2 Sensor PN 15-100-0015 REF A1418-SW203MU For M8000 M9000 M9500
Biolight BLT Reusable Neonatal Infant Spo2 Sensor PN 15-100-0015 REF A1418-SW203MU For M8000 M9000 M9500
Product Details:
Brand Name: Biolight
Model Number: 15-100-0015
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Biolight Neonatal Infant SpO2 Cable Type: 15-100-0015
Application: Medical Equipment,ICU,hospital Device Warranty: 90days
Power Supply Source: Electric Rated Voltage: 110V — 240v
Product Conditions: Running Sweetly Product Characteristics: Professional, Reliable,Functional,Durable
Post-sales Service: In The Warranty Period And Non-human Damage Can Go To The Sale Free Of Charge For New Goodness: New And Original
Supported Languages: English,French,Italian,Spanish,Japanese,Hindi,Portuguese,Russian,etc Minimum Purchasing Quantity: 1 Pcs
High Light:

PN 15-100-0015 Infant Spo2 Sensor

,

M9500 Infant Spo2 Sensor

,

A1418-SW203MU Infant Spo2 Sensor

 

Biolight BLT Reusable Neonatal Infant Spo2 sensor PN15-100-0015 REF A1418-SW203MU for M8000 M9000 M9500

 

 

 

► Brief Introduction

The Biolight BLT reusable Neonatal Infant Spo2 sensor PN15-100-0015 is a medical device designed to measure the oxygen saturation levels in the blood of neonatal and infant patients. This sensor is specifically designed for use in neonatal and infant care settings, providing accurate and reliable readings. The sensor is reusable, which allows for multiple uses and reduces the need for frequent replacements. It is compatible with Biolight patient monitors and features a comfortable and secure fit for the patient. Overall, the Biolight BLT reusable Neonatal Infant Spo2 sensor PN15-100-0015 is a vital tool in monitoring the oxygen levels of neonatal and infant patients, ensuring their well-being and timely medical interventions if necessary.

 

 

 

► Principles of Measuring

The measurement of degree of blood oxygen saturation (also known as pulse oxygen saturation, usually shortened as SpO2) adopts the principles of light spectra and volume tracing. The LED emits lights with two specific bandwidths, which are selectively absorbed by hemoferrum and desoxyhemoglobin. The optical receptor measures the changes in the light intensity after the light passes the capillary network and estimates the ratio of hemoferrum and the total hemoglobin.

Abnormal hemoglobin, carboxyhemoglobin, oxidative hemoglobin are not directly measured, for they are not the affecting factors in the measurement of SpO2

The sensor measurement wavelengths are nominally 660nm for the Red LED and 940nm for infrared LED.

Monitor adopts FFT filter and signal correlation techniques to deal with SpO2 module’s pulse waveform signals. Before the measurement of SpO2, the noise produced in the false trace is smoothed so as to the eliminate disturbance in the measurement of saturation. In case of weak blood pulse, the noise produced by some confinements of electrical properties is greatly reduced.

 

 

 

How to work

The Biolight BLT reusable Neonatal Infant Spo2 sensor PN15-100-0015 REF A1418-SW203MU works by measuring the oxygen saturation levels in the blood of a neonate or infant. The sensor uses a combination of light emitting diodes (LEDs) and a photodetector to determine the oxygen saturation level.

The sensor is designed to be attached to the infant's fingertip, toe, or earlobe. The LEDs emit red and infrared light into the tissue, and the photodetector measures the amount of light that is absorbed by the blood.

Oxygenated blood absorbs more infrared light and allows more red light to pass through, while deoxygenated blood absorbs more red light and allows more infrared light to pass through. By comparing the ratios of absorbed red and infrared light, the sensor can calculate the oxygen saturation level of the blood.

The sensor is reusable, meaning it can be cleaned and used on multiple patients. It is important to follow the manufacturer's cleaning instructions to ensure proper hygiene and accuracy of the readings.

 

 

 

Specification

Measurement Rang: 0~100%
Resolution: 1%
Data update period: <13s
Accuracy: At 70~100%, ±2%
At 0~69%, unspecified
Alarm range: 0~100%, continuously adjustable between upper limit and lower limit.

Biolight BLT Reusable Neonatal Infant Spo2 Sensor PN 15-100-0015 REF A1418-SW203MU For M8000 M9000 M9500 0

 

 

 

If you have any questions about Biolight BLT Reusable Neonatal Infant Spo2 sensor PN15-100-0015 REF A1418-SW203MU for M8000 M9000 M9500, please feel free to contact us at any time, we are glad to answer them. Looking forward to receiving your early inquiry. Thanks for Your Cooperation.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.