China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Mindray |
Model Number: | 0152-30-39689 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | 0152-30-39689 Mindray TEL-100 Telemetry Spo2 Module With Extension Cable | Brand: | Mindray |
---|---|---|---|
Part No: | 0152-30-39689 | Use For: | Mindray TEL-100 Telemetry |
SpO2 Range: | 0 To100% | Pulse Rate Range: | 20 To 300 Bpm |
Wavelength: | Red Light To 660 Nm Ultra-red Light To 910 Nm | SpO2 Accuracy (±1 SD): | 70 To 100% ± 2 Bpm (finger Sensor, Adult) 70 To 100% ± 4 Bpm (ear Sensor) <70% Not Defined (all Sensors) |
Pulse Accuracy: | ±3% ±1 Bpm | MOQ: | One Piece |
Highlight: | Mindray TEL-100 Telemetry Spo2 Module,0152-30-39689 Telemetry Spo2 Module |
0152-30-39689 Mindray TEL-100 Telemetry Spo2 Module With Extension Cable
SpO2 measurement principle
SpO2 monitoring is a non-invasive method of measuring the amount of oxygenated hemoglobin and heart rate by measuring the absorption of light at selected wavelengths. The light generated by the probe passes through the tissue and is converted into an electrical signal by the probe's photodetector. The SpO2 module processes the electrical signals and displays a digital value of SpO2 and heart rate on the screen.
After positioning the sensor, connect the sensor to the SpO2 module and then connect the module to the SpO2 connector on the transmitter. Don't forget to connect the SpO2 extension cable. Make sure cables are not tangled and away from ESUs or other electrical equipment. The ECG cable acts as the transmitter's antenna. Even if you are not interested in monitoring the ECG progress, don't forget to connect it to the transmitter.
Note
SpO2 Specifications
SpO2 range | 0 to100% |
Pulse rate range | 20 to 300 bpm |
Wavelength | Red light to 660 nm Ultra-red light to 910 nm |
SpO2 accuracy (±1 SD) | 70 to 100% ± 2 bpm (finger sensor, adult) 70 to 100% ± 4 bpm (ear sensor) <70% not defined (all sensors) |
Pulse accuracy | ±3% ±1 bpm |
Export
CWT Technology HK Limited has a long history of exporting used medical equipment all over the world.
We have customers in many countries, including America, Europe and Colombia, Mexico, Chile, Saudi Arabia, UAE, Southeast Asia, etc.
When you buy from us, you can rest assured that your item will be properly packed and all documents will be prepared according to your instructions. We have excellent relationships with local shipping lines/forwarders and we are able to handle any type of shipping required.
Thank you so much for your attention .If you're interested in 0152-30-39689 Mindray TEL-100 Telemetry Spo2 Module With Extension Cable ,feel free to contact us .Thank you .
Contact Person: Kiara
Tel: 8619854815217