China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | GE |
Model Number: | E-PSMPW |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | GE Datex Ohmeda E-PSMPW Carescape Patient Side Module | Brand: | GE |
---|---|---|---|
Part No: | E-PSMPW | Module Size (W X D X H): | 55 X 135 (175 W/ Tab) X 145 Mm (2.2 X 5.3 (6.9 W/ Tab) X 5.7 In) |
Module Weight: | 0.6 Kg /1.4 Lb | Operation Temperature: | 5 To 40°C / 41 To 104°F |
Parameter: | NIBP,ECG,Pulse Oximetry,Temperature,Invasive Blood Pressure,Respiration, | MOQ: | One Piece |
Warranty: | 90 Days | Condition: | Work In Good |
Highlight: | 1.4 lb Patient Monitor Module,GE Datex Patient Monitor Module |
GE Datex Ohmeda E-PSMPW Carescape Patient Side Module
Specification
Module size (W x D x H) | 55 x 135 (175 w/ tab) x 145 mm (2.2 x 5.3 (6.9 w/ tab) x 5.7 in) |
Module weight | 0.6 kg /1.4 lb |
Operation temperature | 5 to 40°C / 41 to 104°F |
NIBP
NOTE: Non-invasive blood pressure measurement is intended for patients weighing over 5 kg
Measurement range | |
adult | 25 to 260 mmHg |
child | 25 to 190 mmHg |
infant | 15 to 140 mmHg |
Pulse rate range accepted | 30 to 250 bpm |
Typical measuring time | |
adult | < 30 s |
infant | < 25 s |
Inflation limit | |
adult | 280 ±10 mmHg |
child | 200 ±10 mmHg |
infant | 150 ±5 mmHg |
Venous stasis | |
adult | 80 ±5 mmHg / 2 min |
child | 60 ±5 mmHg / 2 min |
infant | 40 ±5 mmHg / 1 min. |
Lead type |
3-Lead (I, II, III) 5-Lead (I, II, III, aVR, aVL, aVF, V)
|
Sweep speeds | 12.5, 25, 50 mm/sec. |
Defibrillation protection | 5000 V, 360 J |
Recovery time | 5 s |
Input impedance | >2.5 MΩ (10 Hz) |
Allowable offset | ±1VDC |
Gain range | 0.2 to 5.0 cm/mV |
Measurement range | 0 to 100% |
Calibration range | 70 to 100% |
Pulse rate from Pleth | |
Measurement range | 30 to 250 bpm |
Accuracy | ±5 bpm or ±5%, whichever is greater |
Resolution | 1 bpm |
Display averaging | 5-20 s |
Measurement range | 10 to 45 °C (50 to 113 °F) |
Measurement accuracy | ±0.1 °C |
Display resolution | 0.1 °C at 25-45 °C with reusable probes |
Temperature test | automatic (every 10 min.) |
Probe type | compatible with YSI 400 series |
Measurement range | -40 to 320 mmHg |
Measurement accuracy | ±5% or ±2 mmHg, whichever is greater |
Zero adjustment range | ±150 mmHg |
Zero time | less than 15 s |
Transducer sensitivity | 5 µV/V/mmHg |
Measurement range | 4 to 120 breath/min |
Accuracy | ±5 breath/min or ±5%, whichever is greater |
Resolution | 1 breath/min |
Gain range | 0.1 to 5cm/ohm |
Patient Side Module E-PSMPW
(1) Module keys
Module keys
The E-PSM(P)W modules have the following direct function keys:
For starting or stopping the NIBP automatic cycling.
For starting or stopping the NIBP manual cycling.
For zeroing pressure channel P1 NOTE: with E-PSMPW only.
For zeroing pressure channel P2 NOTE: with E-PSMPW only.
Thank you for your attention .If you're interested in GE Datex Ohmeda E-PSMPW Carescape Patient Side Module,feel free to contact us .Thank you .
Contact Person: Kiara
Tel: 8619854815217