Product Name: | Mindray Anesthetic Gas (AG) Module P/N 115-043908-00 | Brand: | Mindray |
---|---|---|---|
Part No .: | 115-043908-00 | MOQ: | One Piece |
Condition: | New And Original | Warranty: | 90 Days |
Payment Method: | T/T ,western Union ,Paypal | Payment Terms: | In Full Before The Shipment |
Delivery Time: | 2-3 Working Days | Delivery Method: | DHL ,UPS ,Fedex Etc |
High Light: | Mindray Anesthetic Gas AG Module,115-043908-00 AG Module,Hospital AG Module |
Mindray Anesthetic Gas (AG) Module P/N 115-043908-00 For Hospital
The AG module analyzes gas samples from the patient and calculates CO2, O2, N2O, and AA waveforms and related numerics that include airway respiratory rate and MAC (minimum alveolar concentration).
Measurement range:
HAL, ENF, ISO, SEV, DES: 0~30 %,
N2O: 0~100 %;
awRR: 2~100 rpm
Accuracy:
Full accuracy mode: N2O: 0~20%REL: ±2% ABS, 20~100%REL: ±3%
ABS; HAL,ENF,ISO: 0~1%REL: ±0.15% ABS, 1~5%REL: ±0.2% ABS, >5%REL, not specified; SEV: 0~1%REL: ±0.15% ABS, 1~5%REL: ±0.2% ABS, 5~8%REL: ±0.4% ABS, >8%REL, not specified;
DES:0~1%REL: ±0.15% ABS, 1~5%REL: ±0.2% ABS, 5~10%REL: ±0.4% ABS, 10~15%REL: ±0.6% ABS ,15~18%REL: ±1% ABS ,>18%REL, not specified; awRR:2~60rpm, ±1rpm, >60rpm, not specified
This measurement can be used for adults, pediatrics and neonates.
MESSAGE | CAUSE |
ALARM PRIORITY
|
MACHINE MODE WHEN CHECKED
|
DISABLE WHEN EXTERNAL AG IS IN STANDBY MODE
|
AG Hardware Error |
AG module Hardware Error.
|
Medium | Runtime | Yes |
O2 Sensor Error | Paramagnetic O2 sensor error | Medium | Runtime | Yes |
External AG Self Test Error
|
Module fault or communication failure between the module and anesthesia system
|
Low | Runtime | Yes |
AG Hardware Malfunction
|
AG module hardware malfunction. The AG module enters Standby and measurement stops
|
High | Runtime | Yes |
AG Init Error |
The AG module was installed improperly or malfunctioned.
|
High | Runtime | Yes |
AG No Watertrap |
The AG module watertrap was installed improperly or not installed.
|
Low | Runtime | Yes |
AG Watertrap Type Wrong
|
When the patient type is infant, but the watertrap type is adult/pediatric, this alarm will be triggered
|
Low | Runtime | Yes |
AG Change Watertrap
|
When the actual flow is less than 75 % of the set flow, the alarm indicates that the watertrap is gradually occluded and it is necessary to replace the water trap
|
Medium | Runtime | Yes |
AG Comm Stop |
AG module malfunction or communication failure.
|
High | Runtime | No |
AG Airway Occluded
|
Pump rate is lower than 20 ml/min for 1 second.
|
High | Runtime | Yes |
AG Zero Failed |
Gas measurements may have bad accuracy during zeroing
|
Low | Runtime | Yes |
Mixed Agent and MAC < 3
|
MAC < 3 | Low | Runtime | Yes |
Mixed Agent and MAC ≥ 3 | MAC ≥ 3 | Medium | Runtime | Yes |
Mixed Agent |
Two anesthetic agents are detected but MAC is an invalid value.
|
Medium | Runtime | Yes |
External AG Module Disconnected
|
The external AG module has been disconnected and no O2 sensor is connected
|
High | Runtime | Yes |
Incompatible AG Software Version
|
The AG Version Limit is On, and the AG module is loaded while the AG software version is lower than 1.7.3.0
|
High | Runtime | No |
CO2Over Range N 2 over Range Hal Over Range Enf Over Range Iso Over Range Sev Over Range Des Over Range O2 Over Range Rate Over Range
|
The monitoring value exceeds the measurable range |
Low | Runtime | Yes |