China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | GE |
Model Number: | M1025230 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | GE Datex Ohmeda E-COP Module M1025230 For Monitoring The State Of The Heart | Brand: | GE |
---|---|---|---|
Part No: | M1025230 | Dimensions (H X W X D): | 11.2 X 3.7 X 18.7 Cm (4.4 X 1.5 X 7.4 In) |
Weight: | 0.35 Kg (0.77 Lb) | Temperature: | 10 To 40°C (50 To 104°F) |
Relative Humidity: | 10 To 90% Non-condensing | MOQ: | One Piece |
Warranty: | 90 Days | Delivery Time: | 3-5 Working Days |
Highlight: | GE Datex Ohmeda E COP Module,M1025230 E COP Module |
GE Datex Ohmeda E-COP Module M1025230 For Monitoring The State Of The Heart
The E-COP module integrates the measurement of cardiac output (CO), right ventricular ejection fraction (REF) and invasive arterial pressure (P) by thermodilution on the CARESCAPE™ monitor screen. The E-COPSv module allows additional measurement of combined venous oxygen saturation (SvO2) and central venous oxygen saturation (ScvO2). The module complies with IEC 60601-1 3rd edition.
Features of GE E-COP Module
• The module contains direct keys to the C.O. to start. Measurement and zeroing of invasive pressure channels
• A unique set of automatic CO measurement types
• Up to six COs can edit the average CO measurement.
• Hemodynamic and oxygenation calculation screen view
• Provides the following hemodynamic calculations with indexed values: CI, SV, SI, SVR, SVRI, PVR, PVRI, LVSW, LVSWI, LCW, LCWI, RCW, RCWI, RVEDV, RVEDVI, RVSW, RVSWI+RVESV and RVESVI
• Provides the following oxygenation calculations with indexed values: CaO2, CvO2, C(a-v)O2, VO2, VO2I, RQ, ATMP, VO2 calculation, VO2I calculation, O2ER, DO2, DO2I, PaO2, AaDO2, CcO2, Qs /Qt, CO calculation. and CI calculations.
• Edit calculation input data
• Trend calculation and printing
• Module insertion/removal without interrupting other monitoring. • SvO2, ScvO2, CO and REF measurements are provided by Edwards Lifesciences Corp. compatible catheters.
Specification of GE E-COP Module
Dimensions (H x W x D) | 11.2 x 3.7 x 18.7 cm (4.4 x 1.5 x 7.4 in) |
Weight | 0.35 kg (0.77 lb) |
Operating conditions | |
Temperature | 10 to 40°C (50 to 104°F) |
Relative humidity | 10 to 90% non-condensing |
Storage conditions | |
Temperature | -25 to 60°C (-13 to 140°F) |
Relative humidity | 10 to 90% non-condensing |
Waveform display | |
Range | -30 to 300 mmHg |
Scales | Adjustable in 10 mmHg increments |
Numerical display | |
Resolution | 1 mmHg |
Alarms | Adjustable high and low alarm limits for systolic, diastolic and mean pressures |
Pulse rate | |
Measurement range | 30 to 250 bpm |
Display resolution | 1 bpm |
Accuracy | ±5% or ± 5 bpm |
Invasive blood pressure | |
Measurement range | -30 to 320 mmHg |
Measurement accuracy | ±4% or ±4 mmHg |
Transducer sensitivity | 5 µV/V/mmHg |
Pressure filter | 0 to 22 Hz (-3 dB) adjustable upper limit 4 to 22 Hz |
Thank you so much for your attention .If you're interested in GE Datex Ohmeda E-COP Module M1025230 For Monitoring The State Of The Heart,feel free to contact us .Thank you .
Contact Person: Kiara
Tel: 8619854815217