China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Fisher&Paykel |
Model Number: | 900MR810E |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | Part No. 900MR810E Fisher&Paykel HEALTHCARE 1.5M Adult Heated Wall Reusable Circuit | Brand: | Fisher&Paykel |
---|---|---|---|
Part No .: | 900MR810E | Compatible Machine: | MR810 |
MOQ: | One Piece | Condition: | New & Original |
Tube Length: | 4.92 Feet /1.5 M | Warranty: | 90 Days |
Delivery Time: | 3-5 Working Days | Delivery Method: | DHL ,UPS ,Fedex |
Packaging: | Carton | ||
Highlight: | 900MR810E Patient Monitor Parts,4.92 Feet Tube Patient Monitor Parts |
Part No. 900MR810E Fisher&Paykel HEALTHCARE 1.5M Adult Heated Wall Reusable Circuit
The F&PMR810 system is designed to provide airway humidity to meet patient respiratory and therapeutic needs. When the MR810 heated humidifier is used with the F&P™ heated breathing circuit, humidity output performance is enhanced while reducing the adverse effects of condensation. These advantages provide only one probe to connect to the circuit, simplifying setup.
Features about Fisher&Paykel HEALTHCARE 1.5M Adult heated wall reusable circuit REF 900MR810E
Evartem™ breathing circuit
Product Code | Description | Quantity |
900MR810E | Adult Evasum™ Inspiratory Heated Breathing Circuit with Expiratory Water Trap | 10 Pack |
900MR810 | Adult Eversom™ Inspiratory Heated Breathing Circuit | 10 Pack |
Illustration: 1. MR810 humidifier. 2. MR370 water chamber. 3. 900MR810 Evatherm™ breathing circuit.
About Fisher & Paykel MR810 system
The Fisher & Paykel MR810 system is designed to provide therapeutic levels of heat and humidity to the breathing gas inhaled by the patient when using a continuous or intermittent non-invasive ventilator system or continuous airflow system.
The MR810 system is intended for non-invasive treatment only.
Adding heat and humidity to the supply of cold and dry breathing gas provided by non-invasive ventilation is beneficial in preventing drying of the patient's airway.
The MR810 system is designed for use in hospitals, long-term care facilities and at home with the prescription of a qualified medical professional.
RESPIRATORY HUMIDIFIER MR810 SET UP
1. Slide the humidifier chamber (B) onto the humidifier base (A) and connect the breathing circuit (F). Hang the water intake on the drinking rod (E).
2. Connect the oxygen tube to the O2 flow meter and install the drain hose (D) if necessary. Connection to the patient interface (G).
3. Heating mode (eg 900MR810 / 900MR810E circuit). Connect the heater adapter to the circuit (C).
Note: Remove the spindle from the spindle container.
4. The humidification system is now configured and ready to use. Use the high setting for maximum humidity.
Typical setup for oxygen therapy using a heated breathing circuit
Typical setup for oxygen therapy using an unheated breathing circuit
If you have any interest in Part No. 900MR810E Fisher&Paykel HEALTHCARE 1.5M Adult Heated Wall Reusable Circuit,feel free to contact us .
Contact Person: Kiara
Tel: 8619854815217