Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

Philip VS1 VS2+ Patient Monitor Accessories REF 989803174881 PN 453564243501 Rechargeable Liithium Ion Battery

Philip VS1 VS2+ Patient Monitor Accessories REF 989803174881 PN 453564243501 Rechargeable Liithium Ion Battery

  • Philip VS1 VS2+ Patient Monitor Accessories REF 989803174881 PN 453564243501 Rechargeable Liithium Ion Battery
  • Philip VS1 VS2+ Patient Monitor Accessories REF 989803174881 PN 453564243501 Rechargeable Liithium Ion Battery
  • Philip VS1 VS2+ Patient Monitor Accessories REF 989803174881 PN 453564243501 Rechargeable Liithium Ion Battery
  • Philip VS1 VS2+ Patient Monitor Accessories REF 989803174881 PN 453564243501 Rechargeable Liithium Ion Battery
Philip VS1 VS2+ Patient Monitor Accessories REF 989803174881 PN 453564243501 Rechargeable Liithium Ion Battery
Product Details:
Brand Name: Philip
Model Number: 989803174881 / 453564243501
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: REF 989803174881 PN 453564243501 Philip VS1 VS2+ Patient Monitor Rechargeable Liithium Ion Battery Brand: Philip
Ref: 989803174881 Part No .: 453564243501
Type: Lithium Ion Volt: 10.8–11.1 V
Capacity: 2150–2300 MAhr Operating Time: >4.5 Hours, With Continuous SpO2 And NBP Interval Measured Every 15 Minutes
Weight: 0.15kg Dimensions: 5.5*2*6.8cm
Condition: Original New
High Light:

989803174881 Patient Monitor Accessories

,

453564243501 Patient Monitor Accessories

,

Rechargeable Liithium Ion Battery

 

REF 989803174881 PN 453564243501 Philipilip VS1 VS2+ Patient Monitor Rechargeable Liithium Ion Battery

 

 

 

 

The rechargeable lithium-ion battery used in the display is a smart battery with built-in circuitry that sends battery status information to the display. Battery power lasts at least 4.5 hours (VS2+) without printing (VS2+ only), with NBP measurements taken every 15 minutes. Follow these guidelines:

 

  • If the battery appears damaged or shows signs of leaking, replace it immediately.
  • Never use a defective battery in the monitor.
  • Do not dispose of batteries in ordinary waste containers.
  • Never leave batteries inside the monitor if not in use for an extended period of time.
  • Never store batteries with more than 50% charge

 

 

Replacement battery

Replace the battery if the following condition occur:

 

  • After refurbishment, if the monitor runs on a fully charged battery for less than an hour before the low battery alarm occurs.
  • After readjustment, if the maximum error value does not exceed 2%.
  • If the battery is not charged to full capacity after four refurbishment cycles.

 

 

 

Type Lithium ion
Volt 10.8–11.1 V
Capacity 2150–2300 mAhr
Operating Time >4.5 hours, with continuous SpO2 and NBP interval measured every 15 minutes
Weight 0.15kg
Dimensions

5.5*2*6.8cm

 

 

Battery Information and Alarms The condition of the battery is reported through messages, technical alarms and error codes.

When the monitor is in standby mode, the information required for battery service will appear if:

  • The maximum error value exceeds 8%.
  • The full capacity value is half of the design capacity value.

 

The information area of the Technical Alarm Monitor displays the following battery technical alarms:

  • Low Battery - Less than 30% battery charge remaining.
  • Very Low Battery Power - Less than 21% battery power remaining.

 

 

 

Warning: Dispose of used batteries in an environmentally responsible manner. Do not put batteries in ordinary waste containers. Check with your hospital administrator for local arrangements.

 

NOTE Before removing the battery, perform a hard shutdown.

 

 

 

  • Perform a hard shutdown and disconnect the power cord from the rear of the monitor.
  • If your monitor has a desktop base, remove it by removing the two TorxT20 screws from the bottom of the base.

 

Philip VS1 VS2+ Patient Monitor Accessories REF 989803174881 PN 453564243501 Rechargeable Liithium Ion Battery 0

 

  • Remove the TorxT10 screws from the battery cover on the bottom of the monitor

Philip VS1 VS2+ Patient Monitor Accessories REF 989803174881 PN 453564243501 Rechargeable Liithium Ion Battery 1

 

4.Disconnect the battery cable from the connector and remove the battery from the monitor.

Philip VS1 VS2+ Patient Monitor Accessories REF 989803174881 PN 453564243501 Rechargeable Liithium Ion Battery 2

 

 

Installing battery

 

1. Connect the battery cable. Make sure the cable is securely attached to the connector.

Philip VS1 VS2+ Patient Monitor Accessories REF 989803174881 PN 453564243501 Rechargeable Liithium Ion Battery 3

2. Insert the battery into the compartment with the cable closest to the case.

3. Replace the battery cover and TorxT10 screws.

 

4.Confirm that the battery is installed correctly by observing if the charging LED lights up

 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.