COMEN STAR 8000 C80 C50 C70 NC8 Patient Monitor ECG Cable 5 Leads Compatible

COMEN STAR 8000 C80 C50 C70 NC8 Patient Monitor ECG Cable 5 Leads Compatible

  • COMEN STAR 8000 C80 C50 C70 NC8 Patient Monitor ECG Cable 5 Leads Compatible
  • COMEN STAR 8000 C80 C50 C70 NC8 Patient Monitor ECG Cable 5 Leads Compatible
  • COMEN STAR 8000 C80 C50 C70 NC8 Patient Monitor ECG Cable 5 Leads Compatible
  • COMEN STAR 8000 C80 C50 C70 NC8 Patient Monitor ECG Cable 5 Leads Compatible
COMEN STAR 8000 C80 C50 C70 NC8 Patient Monitor ECG Cable 5 Leads Compatible
Product Details:
Brand Name: Comen
Model Number: ECG Cable
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Comen Type: ECG Cable
Application: Medical Equipment,ICU,hospital Device Warranty: 90days
Color: White MOQ: One Pcs
Product Situation: In Good Order Mode Of Transport: Expressage
Product Type: Medical Accessories,cables Inventory Situation: Sufficient Inventory
Business Purposes: Original Assembled Real Product, Quality Guarantee, Deliver On Time, Preference Price Gain Selection: X0.125, X0.25, X0.5, X1, X2, X4, Auto
Sweep Speed: 6.25, 12.5, 25, 50mm/s Working Temoerature: 0-40
Humidity: 15-85%
High Light:

NC8 Patient Monitor ECG Cable

,

5 Leads Patient Monitor ECG Cable

 

 Medical Accessories COMEN STAR 8000 C80 C50 C70 NC8 patient monitor ECG cable 5 leads compatible

 

 

► Brief Introduction

ECG monitoring describes continuous waveforms of cardiac activities of patients so as to accurately assess the current psychological status of the patients. Thus proper connection of ECG cables must be ensured in order to obtain correct measurement values.

 

 

► Preparation

Take the preparation of the patient's skin before installing the electrodes:

  1. Make sure good contact between electrodes and skin, because skin is bad conductor,it is very important to prepare the patient's skin well.
  2. Remove the hair of the body surrounding the pole positions if necessary.
  3. Clean the skin thoroughly with soap and water (do not use ethyl ethyl or pure alcohol, because they will increase skin resistance)
  4. Wipe the skin well to increase capillary blood flow and remove skin scraps and oils.
  5. Install the spring or snap clamp before installing the electrodes
  6. Place electrodes on the patient's body. If the electrodes do not contain a conductive paste, cover the conductive dough before installation.
  7. Confirm the power supply

 

Install ECG leads
The following table lists the lead names under the European and US standards (leads are represented in R, L, N, F and C under the European standard and in RA, LA, RL, LL, and V under the US standard)

US standard European standard
Lead name Color Lead name Color
RA White R Red
LA Black Lead name Yellow
LL Red F Green
RL Green N Black
V Brown C White

 

 

5-lead ECG electrodes position

 

COMEN STAR 8000 C80 C50 C70 NC8 Patient Monitor ECG Cable 5 Leads Compatible 0

.

  1. RA: Under the clavicle, near by R-shoulder.
  2. LA: Under the clavicle, near by L-shoulder.
  3. RL: On the R-lower quadrant.
  4. LL: On the L-lower quadrant.
  5. V: On the clest, the electrodes must be put at optional of the position.

Attention

For patient safety, all the leads must be connected with patient body.

For 5-lead device, put the breast (V) electrode at one of the following positions:

  • V1, around the 4th frame at right side to the breast bone
  • V2, around the 4th frame at left side to the breast bone
  • V3, between V2 and V4
  • V4, around the 5th frame along middle line of the left clavicle
  • V5, at front line of the left axilla, at the same horizontal position of V4
  • V6, at middle line of the left axilla, at the same horizontal position of V4
  • V3R-V7R, at right side of the breast, identical to those positions at left side
  • VE, at apoPhilipilipysis of the xiPhilipilipoid process; in case V leads are put on the back, the electrodes must be put at one of the following position:
  • V7, around the 5th frame at back line of the left axilla on the back
  • V7R, around the 5th frame at back line of the right axilla on the back

 

 

Thank you for your time and interest in Medical Accessories COMEN STAR 8000 C80 C50 C70 NC8 patient monitor ECG cable 5 leads compatible. "Quality assurance" is our eternal pursuit and promise. Don't be hesitant to contact us! Welcome to place your orders.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Anna Hu

Tel: +8615083619413

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.