China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Envitec |
Certification: | CE |
Model Number: | OOM102-1 OOM202 OOM201 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | OOM102-1 OOM202 OOM201 Envitec Oxygen Sensor O2 Sensor | Brand: | Envitec |
---|---|---|---|
Part Number: | OOM102-1 OOM202 OOM201 | Warranty: | 90 Days |
MOQ: | One Piece | Delivery Time: | 3-5 Working Days |
Delivery Method: | DHL ,UPS ,Fedex | Payment Terms: | Full Before Shipment |
Condition: | New And Original | ||
Highlight: | OOM102-1 Cell Sensor,OOM202 Cell Sensor,OOM102 Cell Sensor |
OOM102-1 OOM102 OOM202 OOM201 Envitec Oxygen Cell Sensor 100% Genuine New
The EnviteC medical oxygen sensor is designed to be used as the oxygen sensor component of the oxygen analyzer to measure the oxygen concentration in the following breathing gas mixture
application:
Sensing device for oxygen in
• Oxygen concentrator control device
• Medical ventilator
• Anesthesia equipment
• Incubator.
Use is limited to system monitoring. The sensor is not suitable for breath analysis of breathing gas. Please refer to
To the instructions for use! If the sensor is going to be replaced
The original oxygen sensing component of the oxygen analyzer,
Please refer to the EnviteC XRL cross-reference list to select
The right sensor
Technical Specifications OOM202
Model Number | OOM202 |
Nominal Sensor Lifetime | 250000 Percent Volume Oxygen Hours |
Electrical Interface | Gold Plated Slip Rings |
Output Signal in Air | 170A - 230A No Temperature Compensation |
Response Time T 90% | Less Than 12 Seconds |
Weight | Approx. 28 Grams |
Usage | Hospital |
Technical Specifications OOM102-1 OOM102
Model / Part Number | OOM102-1 |
Target gases | OXYGEN |
Measuring Range | 0-100% |
Operating Voltage | 5V |
Oxygen Pressure Range | 2 bar |
Technical Specifications OOM201
Measurement range | 0 % ... 100 % oxygen (at atmosPHiliphhiliperic pressure) |
Nominal sensor lifetime | ≥ 500 000 % volume oxygen hours |
Output in ambient air | 14 mV ... 20.7 mV (Dual Cathode), load 600 Ohms |
Electrical interface | Gold plated slip rings |
Accuracy | meets ISO 80601-2-55 requirements |
Repeatability | < 1 % volume O2 at constant temperature and pressure |
Linearity error | < 3 % relative |
Response time | < 12 s to 90 % of final value |
Zero offset voltage | < 200 µV in 100 % nitrogen, applied for 5 min |
Cross interference | meets ISO 80601-2-55 requirements |
Influence of humidity | -0.03 % rel. per % RH at 25 °C |
Pressure range | 0.6 bar ... 2 bar (ppO2 0 ... 1250 mbar O2 ) |
Influence of pressure | proportional to change in oxygen partial pressure |
Influence of mechanical shock | < 1 % relative after a fall from 1 m |
Operating temperature | 0 °C ... +50 °C |
Temperature compensation | no temperature compensation |
Operating humidity | 0 % ... 99 % RH non-condensing |
Long term output drift | < 1 % volume oxygen per month typically < -15 % relative over lifetime |
Storage temperature | -20 °C ... +50 °C |
Recommended storage | +5 °C … +15 °C |
Recommended load | ≥ 10 kOhms |
Warm-up time | < 30 minutes, after replacement of sensor |
Weight | approximately 28 grams |
Part number | 01-00-0014 |
Mechanical drawing (All dimension in mm)
Contact Person: Kiara
Tel: 8619854815217