Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

Mindray City MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708

Mindray City MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708

  • Mindray City MOX-4  MOX4  O2  Oxygen  Sensor Cable 122009708
  • Mindray City MOX-4  MOX4  O2  Oxygen  Sensor Cable 122009708
  • Mindray City MOX-4  MOX4  O2  Oxygen  Sensor Cable 122009708
  • Mindray City MOX-4  MOX4  O2  Oxygen  Sensor Cable 122009708
  • Mindray City MOX-4  MOX4  O2  Oxygen  Sensor Cable 122009708
Mindray City MOX-4  MOX4  O2  Oxygen  Sensor Cable 122009708
Product Details:
Brand Name: Mindray
Model Number: 122009708
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: Mindray MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708 Brand: Mindray
Part No: 122009708 Operating Principle: Partial Pressure Electrochemical
Output: 9 MV To 13 MV In 210 MBar O2 Measurement Range: 0 MBar To 1500 MBar O2
Baseline Offset: <200 μV Condition: New
MOQ: One Piece Warranty: 90 Days
High Light:

122009708 MOX-4 Oxygen Sensor Cable

,

122009708 Oxygen Sensor Cable

Mindray MOX-4 Oxygen Sensor Cable 122009708

 

 

About Mindray MOX-4 Oxygen Sensor Cable 122009708

 

The Mindray MOX-4 Oxygen Sensor Cable is a replacement cable used with the Mindray MOX-4 oxygen sensor. This cable is designed to

 

provide a reliable connection between the sensor and the monitoring device, ensuring accurate and consistent oxygen level readings. It is an

 

 

essential component for patient monitoring in hospital settings and healthcare facilities.

 

 

Specification of Mindray MOX-4 Oxygen Sensor

 

MEASUREMENT
Operating Principle Partial pressure electrochemical
Output 9 mV to 13 mV in 210 mBar O2
Measurement Range 0 mBar to 1500 mBar O2
Baseline Offset <200 μV
ENVIRONMENTAL
Typical Applications Critical care anesthesia
Operating Temperature Range Range -20°C to +50°C
Operating Pressure Range 0.5 Bar to 2.0 Bar
Operating Humidity Range 0% to 99% RH noncondensing

 

 

 

Purpose of use

These sensors are designed for oxygen partial pressure monitoring in anesthesia (except xenon), intensive care, neonatal incubators and general

 

oxygen monitors.

 

 

 

Stabilization time.

 

Wait at least 15 minutes for the instrument to stabilize before calibrating or refer to the manufacturer's instructions.

 

 

 

Cleaning and sterilization

 

If the sensor is dirty, clean it with distilled water and allow it to air dry. This sensor is not suitable for steam sterilization or exposure to chemicals

 

such as ethylene oxide or hydrogen peroxide.

 

 

 

Calibration interval

 

If the sensor is dirty, clean it with distilled water and allow it to air dry. This sensor is not suitable for steam sterilization or exposure to chemicals

 

such as ethylene oxide or hydrogen peroxide.

 

 

 

If you drop the sensor

 

If a sensor is dropped, it must be isolated for 24 hours and then a two-point calibration performed.

 

 

mechanical installation

 

When installing the sensor, simply screw it in tightly by hand to ensure a tight seal. Do not use wrenches or similar mechanical devices as

 

excessive force may damage the sensor threads.

 

 

Photos 

 

Below picture is Mindray City MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708 New .The cable condition is new .

 

 

Mindray City MOX-4  MOX4  O2  Oxygen  Sensor Cable 122009708 0

 

 

About us

 

CWT Technology HK Limited is a developing company ,mainly selling patient monitor ,ECG ,defibrillator ,ultrasound ,spare parts ,accessories

 

.With the developing ,our customers are from all over the world,such as USA ,Italy ,Spain ,Malaysia ,Philippines,Indonesia ,Thailand ,Colombia

 

,Saudi Arabic ,United Arab Emirates ,Oman etc .

 

 

Thank you so much for your attention .If you're interested in Mindray MOX-4 MOX4 O2 Oxygen Sensor Cable 122009708 ,feel free to contact us .Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.