Goldway UT4000F Monitor ECG Board
Philip Goldway UT4000F Patient Monitor ECG Board GW4F4E01C Medical Spare Parts
► Brief Description
Philip Goldway UT4000F Patient Monitor ECG Board GW4F4E01C
Goldway UT4000F Monitor ECG Board - This board is used, but is fully functional and in good condition. It can connect to the motherboard and other parts and receive instructions from the motherboard. When ECG monitoring is performed on the patient, this board will start to work accordingly.
This board will be carefully inspected before shipment to ensure it meets your usage requirements. All products of our company have a 90-day warranty. If you have any quality problems with this Goldway UT4000F Monitor ECG Board after you receive it, you can contact us at any time for processing.
► Specification
Brand: | Philip Goldway |
Product Category: | Monitoring |
Product Type: | Spare Parts |
Item Type: | Board |
Item Name: | ECG Board |
Application Site: | ECG |
Application Machine: | UT4000F |
Model: | GW4F4E01C |
Color: | Green |
Size: | Small |
Condition: | Used - Good |
Warranty: | 90 Days |
► More Details
Generally, before starting to test the patient, an ECG test will be performed. The steps are as follows:
1. First, you need to adjust the ECG simulator to a heart rate of 80bpm and an ECG gain of 1mV;
2. Connect one end of the ECG cable and lead wire cable to the ECG connector interface of the UT4000F patient monitor, and the other end to the simulator;
3. Observe the ECG channel to see if there is any murmur in ECG lead II. When the R wave appears, there will be a "beep" sound;
4. Check whether there is ECG waveform and noise interference in each ECG lead; adjust the ECG gain to 2mV and observe whether there is any change in the ECG waveform;
5. Unplug the RA from the simulator and observe whether the screen prompts "lead off";
6. Reconnect the RA lead and set the 1mV calibration, and observe whether the 1mV calibration square wave overlaps. The ECG test is completed.
► ECG Performance Specifications
Patient Safety Standard | IEC60601-1-1988 |
CMRR | ≥60dB (Common Mode Rejection Ratio) |
Measure Range | 15 ~ 300bpm ± 1bpm |
Heart Rate Averaging | 8 second average |
ST Segment Range | -0.8 ~ + 0.8mV |
Interface | AAMI 6-pin |
Lead Selection |
I, II, III (3 lead mode) I, II, III, aVR, aVL, aVF, V (5 lead mode) |
Lead Fault Alarm | Audible, Visual |
Input | 5-lead ECG patient cable |
QRS Indicator | Audible and Visual Alert |
Waveform Storage | 6 minutes |
Sweep Speed | 12.5/25/50 mm/sec |
Gain Selection | 4mV, 2mV, 1mV, 0.5mV, 0.25mV,Auto |
Trends | 2 hours → 4 hours → 8 hours → 24 hours → 48 hours |
Patient Isolation | Breakdown voltage: 4000VAC, 50Hz, 60 seconds, Leakage current: <10A |
Frequency width |
Monitoring mode: 0.5 ~ 40Hz (+0.4dB,-3.0dB) Surgery mode: 0.5 ~ 20Hz (+0.4dB, -3.0dB) (not calibration significant) |
Patient Drive Current | < 10A |
Enclosure Leakage Current | < 0.1mA |
Maximum T wave Rejection Capability | 1.2mV |
Heart Rate Alarm Response Time | < 7 seconds |
Aspect Ratio | 0.24 ~ 0.6 sec/mV |
Defibrillator Protected & ESIS Protected | Tested with 5kV |
Recovery Time Following Defibrillation | < 5 seconds |