Product Details:
Brand Name: Mindray
Model Number: T6
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Patient Monitor: Mindray BeneView T6 Patient Bedside Monitor For Hospital Clinic Brand: Mindray
Model NO .: T6 Condition: Used
Height: 15.7 In (40 Cm) Width: 14.6 In (37 Cm)
Depth: 7.6 In (19.3 Cm) Weight: 21.6 Lbs (9.8 Kg)
Screen Type: Color TFT LCD Screen Size (Diagonal): 15 In
High Light:

Mindray BeneView T6 Patient Bedside Monitor

,

Clinic Patient Bedside Monitor

Mindray BeneView T6 Patient Bedside Monitor For Hospital Clinic

Mindray BeneView T6 patient monitor

 

This patient monitor is designed to monitor a fixed set of physiological parameters including ECG, heart rate (HR), respiration (Resp), temperature (Temp), SpO2 ,pulse rate (PR),non-invasive blood pressure (NIBP), invasive blood pressure (IBP), cardiac output (C.O.) carbon dioxide (CO2),oxygen (O2),anesthetic gas (AG), impedance cardiograph (ICG),bispectral index (BIS), respiration mechanics (RM), continuous cardiac output (PiCCO),central venous oxygen saturation (ScvO2),electroencephalograph (EEG), and neuromuscular transmission (NMT).

 

 

The patient monitor Features

 

l Provides audible and visual alarm indications in case of patient or equipment problems.

l Enables displaying, reviewing, storing and transferring of real-time data.

l Incorporates multiple input devices such as buttons, knob, touchscreen, keyboard and mouse.

l Interfaces a clinical information system or central monitoring system.

l Enables program upgrade over the network.

l Integrates the information of other devices, which include but are not restricted to anesthesia machine and ventilator

 

 

 

Specification

 

Height 15.7 In (40 cm)
Width 14.6 In (37 cm)
Depth 7.6 In (19.3 cm)
Weight 21.6 lbs (9.8 kg)
Screen Type Color TFT LCD
Screen Size (Diagonal) 15 In
Resolution 1280×1024 pixels

Wireless Network Frequency Range

 

2.412 to 2.462GHz
Battery Type Lithium-Ion
Voltage 11.1 VDC
Capacity 4500 mAh
Run time 120 minutes when powered by two new fully-charged batteries (25 , ECG, SpO ℃ 2, Auto NIBP measurements at intervals of 15 minutes)

 

 

Basic Operations

 

Turning Power On

 

1. Before beginning measurements, inspect the patient monitor, SMR, and plug-in modules for mechanical damage and ensure that all cables, connectors, and external accessories are properly connected.

2. Connect the power cord to an AC power source. If the patient monitor is battery powered, make sure the battery is fully charged. 3. Press the 3.power switch on the front of the monitor. The home screen appears, the technical light and the indicator light turn blue and yellow respectively. The alarm light will turn red and turn off along with the technical alarm light after the system beeps.

4. The monitor enters the home screen.

 

Starting Monitoring

 

1. Decide what measurements you want to make.

2. Connect the necessary modules, patient cables and sensors. Check that patient cables and sensors are properly connected.

3. Check that patient settings such as [Cat. Patient], [Stimulator], etc., suitable for the patient.

4. Details of the necessary measurements can be found in the appropriate measurement section

 

Disconnecting from Power

 

To disconnect the patient monitor from the power supply, follow these steps:

 

  • Ensure patient observation is complete.
  • Disconnect the patient cables and sensors from the patient.
  • Be sure to backup or delete patient monitoring data if necessary. 4. 4.Press and hold the power button for more than 2 seconds. The patient monitor will turn off and you can unplug the power cord. If the patient monitor does not turn off properly, turn it off by pressing and holding the power button for 10 seconds.

Mindray BeneView T6 Patient Bedside Monitor For Hospital Clinic 0

 

Thank you so much for your attention .If you're interested in ,feel free to contact us .Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.