China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Dräger |
Model Number: | MS18986 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | Drager Infinity Vista XL Patient Monitor REF MS18986 Used | Brand: | Dräger |
---|---|---|---|
Model NO: | MS18986 | Size H X W X D: | 253 X 365 X 190 Mm (10.0 X 14.4 X 7.5 In.) |
Weight With External Battery: | 6.4 Kg (14.0 Lbs.) | Display Size: | Thin Film Transistor-Liquid Crystal Display Active Matrix (TFT-LCD) |
Size (Delta): | 264 Mm (10.4 In.) Diagonal | Channels: | 5 Standard, 6, 8 Optiona |
Viewing Area: | 211 X 158 Mm (8.3 X 6.2 In.) | Resolution: | 640 X 480 Pixels |
Input Voltage: | 11 To 15 V DC | Power Consumption: | ≤70 Watts (fully Loaded) |
Highlight: | Used Patient Monitor REF MS18986,Drager Infinity Vista Used Patient Monitor |
Drager Infinity Vista XL Patient Monitor REF MS18986
Drager Infinity Vista XL Patient Monitor REF MS18986 Used For Neonatal Pediatric And Adult
Drager Infinity Vista XL Patient Monitor REF MS18986 Features
- Works as a standalone device or connects to Infinity Network via DirectNet or wireless adapter for seamless wired to wireless networking
– Scales using software options
– Provides laser printer reports and strip chart recordings
Specification of Drager Infinity Vista XL Patient Monitor REF MS18986
Physical Specifications
Cooling | Convection |
Size H x W x D | 253 x 365 x 190 mm (10.0 x 14.4 x 7.5 in.) |
Weight | 5.8 kg (12.7 lbs.) |
Weight with external battery | 6.4 kg (14.0 lbs.) |
DISPLAY SPECIFICATIONS
Type | Thin Film Transistor-Liquid Crystal Display Active Matrix (TFT-LCD) |
Size (Delta) | 264 mm (10.4 in.) diagonal |
Channels | 5 standard, 6, 8 optiona |
Viewing area | 211 x 158 mm (8.3 x 6.2 in.) |
Resolution | 640 x 480 pixels |
Rotary knob | Easy-to-use menu structure and fixed keys |
Alarms
Priorities | 3; High (Life Threatening), Medium (Serious), Low (Advisory) |
Audio alarm tones | User Selectable: Infinity, IEC 12 or IEC 22 |
Electrical Specifications
Input voltage | 11 to 15 V DC |
Power consumption | ≤70 Watts (fully loaded) |
Patient leakage current | ≤10 mA |
Power requirements | 100 to 240 V AC, 3 A |
Frequency | 50 to 60 Hz |
BATTERY SPECIFICATIONS
Internal battery |
Battery type: lithium-ion Battery capacity: 180 minutes |
Charging time | 6.5 hours at 25° C |
External auxiliary battery | Battery type: sealed lead-acid Battery capacity: 50 minutes Charging time: 3.5 hours at 25° C |
Size (external auxiliary battery) H X W X D |
62 x 182 x 24 mm (2.4 x 7.2 x .9 in.) |
Weight | 0.635 kg (1.4 lbs.) |
Note: Battery capacity varies with different parameter configurations. The above battery capacity is measured under the following load conditions: MultiMed with SpO2 sensor, 2 temperature probes, HemoMed box with 4 IBP sensors and a catheter, NBP measurement every 15 minutes, LCD transmission brightness is 50%, and no continuous beeps are generated.
Environmental Requirements
Temperature range | |
Operating | 10° C to 40° C (50° F to 104° F) |
Storage | -20° C to 40° C (-4° F to 104° F) |
Relative humidity | |
Operating | 20% to 90%, non-condensing |
Storage | 10% to 95% (with packaging) |
Atmospheric pressure | |
Operating | 525 to 795 mmHg (70 to 106 kPa) |
Storage | 375 to 795 mmHg (50 to 106 kPa) |
Thank you so much for your attention .If you're interested in Drager Infinity Vista XL Patient Monitor REF MS18986 Used ,feel free to contact us .Thank you .
Contact Person: Kiara
Tel: 8619854815217