Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsECG Machine Parts

UT-2466 Nihon Kohden ECG Machine Parts Mainboard SMT-5 Including Display Booard USB Network Connector

UT-2466 Nihon Kohden ECG Machine Parts Mainboard SMT-5 Including Display Booard USB Network Connector

  • UT-2466 Nihon Kohden ECG Machine Parts Mainboard SMT-5  Including Display Booard USB Network Connector
  • UT-2466 Nihon Kohden ECG Machine Parts Mainboard SMT-5  Including Display Booard USB Network Connector
  • UT-2466 Nihon Kohden ECG Machine Parts Mainboard SMT-5  Including Display Booard USB Network Connector
  • UT-2466 Nihon Kohden ECG Machine Parts Mainboard SMT-5  Including Display Booard USB Network Connector
  • UT-2466 Nihon Kohden ECG Machine Parts Mainboard SMT-5  Including Display Booard USB Network Connector
  • UT-2466 Nihon Kohden ECG Machine Parts Mainboard SMT-5  Including Display Booard USB Network Connector
  • UT-2466 Nihon Kohden ECG Machine Parts Mainboard SMT-5  Including Display Booard USB Network Connector
UT-2466 Nihon Kohden ECG Machine Parts Mainboard SMT-5  Including Display Booard USB Network Connector
Product Details:
Brand Name: Nihon Kohden
Model Number: UT-2466
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Contact Now
Detailed Product Description
Payment Terms: Full Before The Hsi Product Name: Nihon Kohden CardiofaxS ECG-2250 ECG Machine Mainboard UT-2466 SMT-5 94V-0 Including Display Booard USB NETWORK Connector
Brand: Nihon Kohden Part No: UT-2466
Application: Nihon Kohden CardiofaxS ECG-2250 ECG Machine MOQ: One Piece
Warranty: 90 Days Condition: Used
Packaging: Standard Delivery Method: DHL,UPS ,Fedex
High Light:

UT-2466 ECG Machine Parts

,

Display Booard ECG Machine Parts

UT-2466 Nihon Kohden CardiofaxS ECG-2250 ECG Machine Mainboard SMT-5 Including Display Booard USB NETWORK Connector

Nihon Kohden CardiofaxS ECG-2250 ECG Machine Mainboard UT-2466 SMT-5 94V-0 Including Display Booard USB NETWORK Connector

 

 

 

  • Nihon Kohden cardiofaxS ECG-2250 ECG machine mainboard UT-2466 Brief Introduction

 

The motherboard of the Nihon Kohden Cardiofax S ECG-2250 electrocardiograph is the core component that controls and coordinates the operation of the machine. It houses the microprocessor, memory, and other electronic components needed for the machine to function. The main board receives signals from electrodes placed on the patient, processes the data, and sends the results to a monitor or printer. It also interfaces with other subsystems of the machine, such as power, user interface, and communication ports. The motherboard plays a vital role in ensuring accurate and reliable recording of the patient's ECG.

 

 

  • Nihon Kohden cardiofaxS ECG-2250 ECG machine mainboard UT-2466 Specification

 

Product Name Nihon Kohden cardiofaxS ECG-2250 ECG machine mainboard UT-2466 SMT-5 94V-0 including display booard USB NETWORK connector
Brand Nihon Kohden
Part No UT-2466
Application Nihon Kohden cardiofaxS ECG-2250 ECG machine
MOQ One piece
Warranty 90 days

 

 

 

 

  • Use and maintenance of the electrocardiograph

 

The sole function of an electrocardiograph, a high-precision electronic medical device, is to accurately detect, amplify, and transmit weak human electrophysiological signals to a display screen. From this, it is easy to imagine that the accuracy of the detection signal in the front stage of the electrocardiograph directly determines the accuracy of the rear stage and the overall output, and the final output result may be wrong by tens of times. or it can be more. The following five points should be considered by healthcare professionals regarding the use and maintenance of electrocardiograph electrodes and leads.

 

 

① After each use of the electrode, the conductive paste or salt water on the surface should be wiped off, so as to reduce the corrosion of the electrode as much as possible;

②If you find oxidation or rust spots on the surface of the silver-plated electrode, just use a flannel cloth to wipe it, and never use sandpaper to polish it;

 

③ If it is found that the electrode is deformed, the silver skin is peeled off, or part of the copper is exposed due to abrasion, then the electrode can no longer be used;

 

④ Do not use the new electrode replaced by the ECG machine immediately, but soak it in sodium chloride solution for several hours before use;

 

⑤ When pulling out the plugs of the lead wires after use, the plugs must be pulled out by hand, and the wires must not be pulled out, otherwise the wires will be easily damaged or even broken..

 

UT-2466 Nihon Kohden ECG Machine Parts Mainboard SMT-5  Including Display Booard USB Network Connector 0

 

Thank you so much for your attention .If you're interested in  UT-2466 Nihon Kohden CardiofaxS ECG-2250 ECG Machine Mainboard SMT-5 Including Display Booard USB NETWORK Connector ,feel free to contact me .Thank you .

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.