Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsECG Machine Parts

Edan 5 Lead Snap AHA Reusable ECG Cable REF EL05DASY For Edan IT20 Telemetry Ransmitter

Edan 5 Lead Snap AHA Reusable ECG Cable REF EL05DASY For Edan IT20 Telemetry Ransmitter

  • Edan 5 Lead Snap AHA Reusable ECG Cable REF EL05DASY For Edan IT20 Telemetry Ransmitter
  • Edan 5 Lead Snap AHA Reusable ECG Cable REF EL05DASY For Edan IT20 Telemetry Ransmitter
  • Edan 5 Lead Snap AHA Reusable ECG Cable REF EL05DASY For Edan IT20 Telemetry Ransmitter
  • Edan 5 Lead Snap AHA Reusable ECG Cable REF EL05DASY For Edan IT20 Telemetry Ransmitter
Edan 5 Lead Snap AHA Reusable ECG Cable REF EL05DASY For Edan IT20 Telemetry Ransmitter
Product Details:
Brand Name: Edan
Model Number: EL05DASY
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Edan Type: EL05DASY
Warranty: 90days Product Type: Lead Set
Single-Patient Use OR Multi-Patient Use: Multi-Patient Use Minimum Shelf Life: None
AfterSales: In The Warranty Period And Non-human Damage Can Go To The Sale Free Of Charge For New Company Objectives: Original Assembled Real Product, Quality Guarantee, Deliver On Time, Preference Price
Product Situation: In Good Condition Features Introduction: Easy To Use,Professional, Reliable
MEANS OF TRANSPORT: Expressage
High Light:

Reusable ECG Cable

,

REF EL05DASY ECG Cable

 

 

Edan 5 lead Snap AHA Reusable ECG Cable REF EL05DASY 02.04.241961 for Edan iT20 Telemetry Transmitter

 

 

 

► Brief Introduction

When accessory is not compatible, the screen will display “Check the ECG accessories”; When compatible and ECG module is active, telemetry transmitter will check ECG leads connection. The screen will enter into main interface under condition of correct leads connection. Under leads off or wrong connection, the screen will display ECG leads connection sketch in which wrongleads position and correct leads position will be indicated. ECG leads connection sketch will disappear in these conditions, leads connection restoring normally, pressing shifting key or over 60 seconds.

 

 

 

► Connecting ECG Cables

  • Attach clip or snap to electrodes prior to placement.
  • Put the electrodes on the patient. Before attaching, apply some conductive jelly on the electrodes if the electrodes are not electrolyte self-supplied.
  • Connect the electrode lead to the patient's cable.
  • Plug the patient cable into the ECG connector.

 

 

Electrode Placement for 5-lead

Take the American standard for example; see the following figure:

■ RA placement: directly below the clavicle and near the right shoulder.

■ LA placement: directly below the clavicle and near the left shoulder.

■ RL placement: on the right hypogastrium.

■ LL placement: on the left hypogastrium.

■ V placement: on the chest, the position depends on your required lead selection

Edan 5 Lead Snap AHA Reusable ECG Cable REF EL05DASY For Edan IT20 Telemetry Ransmitter 0

 

► Cleaning the ECG Cable Assembly

Wipe the cable assembly with a soft cloth dampened with the cleaning solution until no visible contaminants remain.

Wipe off the cleaning solution with a fresh cloth or towel, dampened with tap water after cleaning until no visible cleaning agent remains..

Wipe off with a dry cloth to remove residual moisture.

Leave the cable assembly to air dry

 

 

 

Specification

Lead naming style AHA, IEC
Sweep MFM-CMS: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Telemetry Transmitter: 12.5 mm/s
Auxiliary Current (Leads off detection) Active electrode: <100 nA
Reference electrode: <900 nA

 

 

 

► About Company

We cater to all biomedical facility needs - service, repair, rental, and purchase and sale of equipment. Safe, reliable and compliant medical device services are our primary goals. We pride ourselves on the individualized attention we provide each client, catering to all aspects of their biomedical facility. Our team of experienced biomedical technicians are trained, certified and equipped with the latest technology and tools to repair and maintain a wide variety of patient care and diagnostic equipment.

Our technicians ensure that all equipment leaving our warehouse is meticulously tested and certified for safety and compliance. We understand the importance of device safety and performance in today's healthcare environment. Providing the most professional customer service and adhering to the highest quality standards is our mission.

 

 

 

Thank you for your time! If you are interested in Edan 5 lead Snap AHA reusable ECG cable REF EL05DASY for Edan iT20 Telemetry ransmitter, welcome to place your orders. Early order early shipment! 

Looking forward to receiving your early inquiry.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.