Drager Spo2 Extension Cable 2m Reusable REF 2606487 In Good Working Condition

Drager Spo2 Extension Cable 2m Reusable REF 2606487 In Good Working Condition

  • Drager Spo2 Extension Cable 2m Reusable REF 2606487 In Good Working Condition
  • Drager Spo2 Extension Cable 2m Reusable REF 2606487 In Good Working Condition
  • Drager Spo2 Extension Cable 2m Reusable REF 2606487 In Good Working Condition
  • Drager Spo2 Extension Cable 2m Reusable REF 2606487 In Good Working Condition
Drager Spo2 Extension Cable 2m Reusable REF 2606487 In Good Working Condition
Product Details:
Brand Name: Drager
Model Number: 2606487
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Drager Type: 2606487
Not Manufactured With Natural Rubber Latex: Yes Warranty: 90days
Color: Gray Product Type: Lead Set
Single-Patient Use OR Multi-Patient Use: Multi-Patient Use Minimum Shelf Life: None
Length: 2 M AfterSales: In The Warranty Period And Non-human Damage Can Go To The Sale Free Of Charge For New
Company Objectives: Original Assembled Real Product, Quality Guarantee, Deliver On Time, Preference Price Product Situation: In Good Condition
Features Introduction: Easy To Use,Professional, Reliable MEANS OF TRANSPORT: Expressage
High Light:

Drager Spo2 Extension Cable

,

2606487 Spo2 Extension Cable

,

Reusable Spo2 Extension Cable

Drager Spo2 Extension Cable 2m reusable REF 2606487 for Drager VISTA 120

 

 

 

► Packing Standard

SpO2 is used to measure arterial oxygen saturation, which is the percentage of oxygenated hemoglobin in arterial blood. SpO2 parameters can also provide pulse rate (PR) and volume map wave (Pleth).

1. Select the correct patient category setting (adult/pediatric and neonatal) as this is used to optimize the calculation of SpO2 and pulse numbers.

2. When measuring, make sure that the application site:

  • With pulsatile flow, ideally with good circulatory perfusion.
  • The thickness of the sensor has not changed, causing the sensor to not fit properly.

 

Be sure to understand all warnings listed in the previous section before applying any sensor to a patient. Also, check the sensors as follows:

  • Check the inside and outside of the sensor. To check inside, gently open the sensor cavity and check for debris on or next to the clear silicone covering the optics.
  • Any sensor showing signs of damage or alteration should not be used for further patient monitoring; instead, dispose of it using appropriate disposal procedures.

 

 

 

 

► Measurement limit

 

Certain patient conditions may affect measurement results or cause loss of pulse signals.

Inaccurate measurements can cause, but are not limited to:

  • Improper sensor application
  • High levels of ambient light sources such as surgical lamps (especially those with xenon sources), bilirubin lamps, fluorescent lamps, infrared heating lamps, and direct sunlight
  • Failure to cover sensor with opaque material in conditions of high levels of ambient light
  • Dysfunctional hemoglobin
  • Low peripheral perfusion
  • Excessive or violent patient movement
  • Venous pulsation
  • Intravascular dyes such as polycyanine green or methylene blue
  • External application of colorants (nail polish, dyes,
  • Defibrillation
  • Placing sensors on limbs, using blood pressure cuffs, arterial catheters, or intravascular lines
  • Electromagnetic interference

 

Loss of pulse signal can occur for the following reasons:

  • The sensor application is too tight
  • Blood pressure cuff expands the same limb with sensor attached
  • Proximal sensor for arterial occlusion
  • Low peripheral perfusion

 

 

Specification

Measurement Rang: 0~100%
Resolution: 1%
Adult (including pediatric) ±2% (70 to 100% SpO2)
Undefined (0 to 69% SpO2)
Neonate ±3% (70 to 100% SpO2)
Undefined (0 to 69% SpO2)

Drager Spo2 Extension Cable 2m Reusable REF 2606487 In Good Working Condition 0

 

 

► Shipping Issues

For delivery time, we will do our best to process demand and ship goods as soon as possible. Please be patient and stay in touch with us. In general, most orders will be shipped within 3 to 5 business days and arrive on time. However, on busy days, shipping may be delayed by more than 5 business days.

If you are in dire need of your product, please make sure to confirm with us before submitting your application. To ensure smooth business operation, please pay special attention and arrange time carefully according to your personal needs. If your order takes longer than expected, or if you want to know exactly when it arrives, feel free to contact us. We're always here to help you.

 

 

 

Thank you for your time! If you are interested in Philipilip ECG leads CBL Unshielded 3 lead mini-clip AAMI 0.45m Grabber, non-shielded 989803144931 M1622A , welcome to place your orders. Early order early shipment! Looking forward to receiving your early inquiry.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.