Brand Name: | Med-tronic |
Model Number: | 3200926-005 H GFI AV038F 4604 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator Flex Cable 3200926-005 H GFI AV038F 4604 | Brand: | Med-tronic |
---|---|---|---|
Part No .: | 3200926-005 H GFI AV038F 4604 | Use For: | LIFEPAK 20(LP20) Defibrillator |
MOQ: | One Piece | Warranty: | 90 Days |
Condition: | Work In Good | Packaging: | Standard |
Payment Terms: | Full Before Shipment | Delivery Method: | DHL,UPS ,Fedex |
Highlight: | LP20 Defibrillator Flex Cable,3200926-005 Defibrillator Flex Cable |
Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator Flex Cable 3200926-005 H GFI AV038F 4604
Flex Cable Removal
Note: Before disassembly begins, the top box must be removed.
To remove the flex cable:
1. Disconnect the two ground straps connecting the top of the front chassis to the system shield from the system shield by removing the two screws.
Note: Note the location on the ground floor. If they are not reattached at the correct angle, the faceplate will not fit properly with the rest of the unit.
2. Pull the front case slightly forward away from the card stack and disconnect the flex cable from the PP circuit board.
3. Disconnect the flex cable from the circuit board and remove the cable from the device.
Flex Cable Installation
To install the UI Flex Cable:
1. Pull the front chassis slightly forward and away from the card stack and connect the user interface flex cable to the user interface board.
Note: Avoid bending the user interface flex cable during installation. Excessive bending can damage cables and connectors.
2. Carefully connect the user interface flex cable to the PP circuit board, making sure the pins are evenly connected to the connectors to avoid
possible pin damage.
3. Attach the two ground straps by attaching the top of the front case to the system shield with the two screws. Note: Note the location of the
ground wire. If they are not reattached at the correct angle, the front panel will not connect properly to the rest of the unit.
4. Put the top cover back on.
Product Name |
Med-tronic Physio-Control LIFEPAK 20(LP20) defibrillator 3200926-005 H GFI AV038F 4604
|
Brand | Med-tronic |
Part No |
3200926-005 H GFI AV038F 4604
|
MOQ | One piece |
Warranty | 90 days |
Condition | Work in Good |
Customer service
Great customer service is our focus to ensure that your business with us meets or exceeds your expectations every time.
All members of our company do their best to respond to any inquiries or concerns from each of our clients.
Let us know what you are looking for and we will let you know when we are able to obtain the medical equipment you need.
So, whether you have any questions, comments or compliments, we want to hear from you
Thank you so much for your attention .If you're interested in Med-tronic Physio-Control LIFEPAK 20(LP20) Defibrillator Flex Cable 3200926-
005 H GFI AV038F 4604,feel free to contact us .Thank you .
Contact Person: Kiara
Tel: 8619854815217