Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer

FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer

  • FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer
  • FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer
  • FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer
  • FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer
FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer
Product Details:
Brand Name: Welch Allyn
Model Number: FTP-628MCL506
Payment & Shipping Terms:
Minimum Order Quantity: One piece
Packaging Details: Standard
Delivery Time: 3-5 working days
Contact Now
Detailed Product Description
Payment Terms: Full Before Shipment Product Name: FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer
Brand: Welch Allyn Part No: FTP-628MCL506
Use For: Welch Allyn Vital Signs Monitor 300 Series 53NTP Printer Type: Thermal
MOQ: One Piece Warranty: 90 Days
Condition: Used Delivery Method: DHL ,Fedex,UPS
High Light:

FTP-628MCL506 Vital Signs Monitor

,

Vital Signs Monitor 53NTP

FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer

 

 

Start and stop printing

• If the monitor is not printing, press FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer 0 to start printing.

• When the monitor is printing, press FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer 0 to stop printing. (If the monitor is configured to print continuously, the printer will print a footer before stopping.)

 

Remarks

The push button is not activated during NIBP breaths or unrecoverable device alarms.

 

batch printing

 

After a period of continuous patient monitoring, the clinician can use the monitor's batch print function to print all measurements stored in the monitor's memory during the monitoring period. When the monitor is configured for batch printing and is in normal operating mode, press to print all readings stored in memory (up to 99 cycles), starting with the oldest reading cycle and print first. During batch printing, a PRINTING message is displayed and all monitor controls other FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer 0 than FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer 3 and are disabled. Batch printing continues until one of the following occurs:

 

• All saved data has been printed.

FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer 0Press again.

• Battery error condition.

• A major error condition has been detected. In either case, printing will stop immediately.

 

Remarks

If the monitor is configured for continuous printing but printing is disabled, you can press FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer 0and hold for 3 seconds to immediately start a batch print job. When this batch job finishes, the monitor is still configured for continuous printing.

 

 

continuous printing

Alternatively, clinicians can print a continuous stream of vital signs and print measurement information immediately after recording the results of each cycle. If the monitor is configured for streaming and is in normal operating mode, press FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer 0 to start streaming immediately. Continuous printing will continue until one of the following occurs:

 

 

FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer 0press again; the monitor prints an error log (if errors occurred) and a footer, then stops printing.

• A major error condition was detected; Printing stopped immediately.

• A battery error condition has been detected. Printing will be paused while the battery error persists; Printing will continue if the AC adapter is connected before the monitor is turned off.

 

 

Product Name

Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal printer FTP-628MCL506

 

Brand Welch Allyn
Part No

FTP-628MCL506

 

Use for Welch Allyn Vital Signs Monitor 300 Series 53NTP
Printer Type Thermal

 

 

FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer 8

 

printer output

Standard printer reports include a header, patient information, patient data (table title, date, time, range, and alarm indicators and readings), error label, and page footer. When the monitor receives a print request but no data is available, it prints only the header and footer.

 

 

Thank you so much for your attention.If you're interested in FTP-628MCL506 Welch Allyn Vital Signs Monitor 300 Series 53NTP Thermal Printer ,feel free to contact us .Thank you ..

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.