China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Comen |
Model Number: | C60 |
Minimum Order Quantity: | 1 |
---|---|
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union,PayPal |
Product Name: | COMEN C60 Patient Monitor | Type: | C60 |
---|---|---|---|
Warranty: | 90days | Applications Scenes: | Patient Monitor |
Key Word: | COMEN C60 Patient Monitor ECG | Product Status: | In Good Working Condition. |
Stock Status: | Stock Available | Minimum Purchasing Quantity: | 1unit |
Lead Type: | 5 Lead And 3 Lead Selectable | Gain Selection: | X0.25, X0.5, X1, X2, X4, Auto |
Sweep Speed: | 6.25, 12.5, 25, 50mm/s | Heart Rate Range: | Pediatric/Neonate: 15-350bpm |
Resolution: | 1 Bpm ±1% Or ±2bpm | ST Segment: | -2.0mV - +2.0Mv |
Detection Arrhythmia: | Yes | ||
High Light: | COMEN C60 Patient Monitor Parts,ECG Connector Patient Monitor Parts |
Hospital Medical Equipment COMEN C60 Patient Monitor ECG Connector in stock with good working condition
COMEN C60 Patient Monitor ECG Connector
► Brief Introduction
ECG monitoring describes continuous waveforms of cardiac activities of patients so as to accurately assess the current psychological status of the patients. Thus proper connection of ECG cables must be ensured in order to obtain correct measurement values. This portable monitor concurrently can display 2 waveforms under normal work status.
A patient cable consists of two parts: Wire connecting the monitor; Leads connecting patients With a 3-lead facility for monitoring, ECG can obtain two waveforms from two different leads.Displayed monitoring parameters include HR, ST segment measurement value and arrhythmia.
► Connect ECG Cable
1) First install the spring clip before placing the electrode.
2) Place the electrode on the patient’s body; if the electrode used does not contain conductive paste, please apply conductive paste prior to placement.
3) Connect the electrode leads with the patient cable.
4) Insert the patient cable into the ECG port on the monitor. The monitor shows the ECG wave and value
► Features
► Precautions for ECG Monitoring
► Specification
Lead Type | 5 lead and 3 lead selectable |
5 leadwire cable | RA; LA; RL; LL; V or R; L; N; F; C |
3 leadwire cable | RA; LA; LL or R; L; F |
Lead Selection | 5-lead: I; II; III; aVR; aVL 3-lead: I; II; III |
Gain Selection | x0.25, x0.5, x1, x2, x4, auto |
Sweep Speed | 6.25, 12.5, 25, 50mm/s |
Heart Rate Range | Pediatric/Neonate: 15-350bpm |
Resolution | 1 bpm ±1% or ±2bpm |
Filter | MON: 0.5-40Hz DIA: 0.05-130Hz OPE: 1-20Hz |
ST Segment | -2.0mV - +2.0Mv |
Detection Arrhythmia | Yes |
Please kindly contact us, if you are interested in COMEN C60 Patient Monitor ECG Connector , Thank you!
Contact Person: Rita
Tel: 8618279091952