Brand Name: | Mindray |
Model Number: | 630D-30-09122 630D-30-09121 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | 630D-30-09122 630D-30-09121 Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump | Brand: | Mindray |
---|---|---|---|
Part No: | 630D-30-09122 630D-30-09121 | Measurement Technique: | Auto Oscillation |
Displayed Parameters: | Systolic Pressure, Diastolic Pressure And Mean Pressure | Mode Of Operation: | Manual, Auto And Continuous |
Measurement Interval In Auto Mode: | 1/2/3/4/5/10/15/30/60/90/120/180/240/480 Minutes | Measurement Time In Continuous Mode: | 5 Minutes |
Measurement Precision: | Maximum Average Error: ±5mmHg Maximum Standard Deviation: 8mmHg | Resolution: | 1mmHg |
Over-pressure Protection: | Adult: 297±3 MmHg Pediatric: 240±3 MmHg Neonate: 147±3 MmHg | Warranty: | 90 Days |
Highlight: | Mindray PM7000 Patient Monitor NIBP Module,Patient Monitor NIBP Module Assembly,630D-30-09121 Patient Monitor Parts |
630D-30-09122 630D-30-09121 Mindray PM7000 Patient Monitor NIBP Module Assembly With Pump
NIBP module introduction
The Non-Invasive Blood Pressure (NIBP) module measures blood pressure using oscillometric methods. This monitor can be used for adult, pediatric and neonatal patients.
There are three measurement modes: manual, automatic, and continuous.
Manual: Press the NIBP button on the control panel to start NIBP measurement.
Automatic: Automatically performs NIBP measurements at preset intervals.
Continuous: NIBP measurements are taken as many times as possible within 5 minutes.
NIBP measurements do not generate waveforms. Instead, the measurements are displayed in the NIBP Parameters window as shown below.
1. NIBP Tab: Select this tab to access the NIBP setup menu.
2. The time of the last measurement.
3. NIBP unit: mmHg or kPa.
4. Quick Information Area: Displays information such as NIBP measurement mode.
5. Systolic blood pressure (SBP)
6. Average pressure value (NM)
7. Diastolic blood pressure (DN)
Specification of NIBP
Measurement technique | Auto oscillation |
Displayed parameters | Systolic pressure, diastolic pressure and mean pressure |
Mode of operation | Manual, auto and continuous |
Measurement interval in auto mode | 1/2/3/4/5/10/15/30/60/90/120/180/240/480 minutes |
Measurement time in continuous mode | 5 minutes |
Measurement precision | Maximum average error: ±5mmHg Maximum standard deviation: 8mmHg |
Resolution | 1mmHg |
Over-pressure protection |
Adult: 297±3 mmHg Pediatric: 240±3 mmHg Neonate: 147±3 mmHg |
Operation Guides
1. Start a manual NIBP measurement
Go to the NIBP SETUP menu and select MANUAL from the INTERVAL option; Then press the NIBP button on the control panel to start manual NIBP measurement; either
To start a manual NIBP measurement between automatic NIBP measurements, press the NIBP button on the control panel.
2. Start the automatic NIBP measurement Go to the NIBP SETUP menu and select a time (e.g. 5 MIN) from the INTERVAL option. Start the automatic NIBP measurement by pressing the NIBP button on the control panel. When the measurement is complete, the system automatically performs a non-invasive blood pressure measurement according to the preset interval.
Warning
Long-term use of automated, non-invasive blood pressure measurements can lead to ischemia and neuropathy in the restricted limb. When observing patients, regularly check the color, temperature and sensation of the extremities. If you notice abnormalities, immediately put the cuff back on the patient or stop the blood pressure measurement.
3. Start continuous NIBP measurement. Select NEXT from the NIBP SETUP menu to start a continuous NIBP measurement. The monitor will continue to measure NIBP for five minutes.
4. Stop NIBP measurement During automatic, manual or continuous measurement, press the NIBP button on the control panel to stop the current measurement.