Application: | Medical Equipment,ICU,hospital Device | Warranty: | 90days |
Color: | White | Operating Temperature: | +10 °C To +40 °C +50 °F To +104 °F |
Operating Altitude: | -170 M To +4877 M -557 Ft To + 16,000 Ft | Shipping Altitude: | -615 M To 12,300 M -2000 Ft To 40,000 Ft |
Storage Temperature: | -20 °C To +50 °C -4 °F To +122 °F | Relative Humidity: | 15% To 90% (non-condensing) |
Printer Current: | Peak (mA): 0.940 MA | ||
Highlight: | 630-0213-10 Vital Sign Monitor,53NTP Recorder Printer Vital Sign Monitor |
Welch Allyn Vital Signs Monitor 300 Series 53NTP Recorder Printer REV A 630-0213-10
In Good working Condition Welch Allyn Vital Signs Monitor 300 Series 53NTP Recorder Printer REV A 630-0213-10
► Brief Introduction
The printer provides a way to view and save patient vital-signs data. It can be configured to print all stored data as a single batch or to print a continuing stream of data as the data is recorded in memory.
The printer standard report consists of a header, patient information, patient data (table heading, date, time, range and alarm flags, and measurement readings), an error legend and a footer. If the monitor receives a print request and no data is available, it prints only the header and footer.
► To Start and Stop Printing
• If the monitor is not printing, press button to start printing.
• If the monitor is printing, press button to stop printing. (If the monitor is set to Stream
printing, the printer prints a footer before stopping.)
► Functional Verification
1. Put the monitor into Service Mode.
2. Verify that the printer has paper.
3. Verify that a settings report prints, and that it contains no printed anomalies and no missing or faded sections.
4. After 2 seconds of printing, verify that the current draw is no more than 2.5A above the baseline current recorded in step 2 of the Baseline Current Draw verification test.
5. Exit the Service Mode
With a new roll of paper, the first line might be faded. This does not indicate a problem.
The settings report contains a calibration record, user record, hardware status record, and software versions record.
• The calibration record includes manufacturing configuration data: monitor serial number, set parameters, and language.
• The user record includes user-configurable settings: alarm limits, patient type, parameter modes/units, auto interval, tone volume, and others.
• The hardware status record shows the hardware revision number, the battery voltage level, the total number of NIBP monitoring cycles completed on the monitor, and the total number of hours of operation of the monitor.
• The software versions record indicates the software version numbers of the main board, SpO 2 and Temperature options (if present), and NIBP.
► Quick Details
Brand | Welch Allyn |
Type | 300 Series 53NTP |
Warranty | 90 Days |
Shipping Date | 3-5 Working Days |
Application | Hospital Devices; Medical Care; ICU; Medical Equipments and Accessories |
► Remove and Disassemble the Printer
1. Remove the printer door.
Open the printer door and remove the roll of printer paper.
Push the printer door toward the rear of the monitor until it snaps out of the two support spindles on the printer frame.
2. Remove the printer assembly.
Push the plastic legs of the printer assembly outward and pull the printer assembly forward to free it from the snap-in seating of the rear chassis bulkhead.