China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Welch Allyn |
Model Number: | 300 Series 53NTP |
Minimum Order Quantity: | 1 |
---|---|
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union,PayPal |
Product Name: | Welch Allyn | Type: | 300 Series 53NTP |
---|---|---|---|
Application: | Medical Equipment,ICU,hospital Device | Warranty: | 90days |
Color: | Green | Power Consumption: | 110V—240v |
Product Conditions: | In Good Order | Power Supply Source: | Electricity |
Management Principle: | Original Assembled Real Product, Quality Guarantee, Deliver On Time, Preference Price | Inventory Status: | Sufficient Inventory |
Peculiarity: | Professional,Useful,Durable In Use | Product Applications Scenarios: | Hospital, Clinic, Hospital Room, ICU,etc |
MEANS OF TRANSPORT: | Expressage | Minimum Purchase Commitments: | 1 Pcs |
Highlight: | 030-0072-03 Patient Monitor Parts,NIBP Module Patient Monitor Parts |
Welch Allyn Vital Signs Monitor 300 Series 53NTP NIBP module REV E007-012702 030-0072-03 REV
►Brief Introduction
Patient Monitor Module Rack is for PHiliphh MP60 MP70 MX600 MX700 MX800 monitor equipment, with the white color.
CWT Technology HK Limited are supply new or second hand medical equipments, accessories and repair parts including patient monitor, defibrillator machine, ECG,EKG machine. All the second hand medical equipment will be inspected by our certified engineers to mark sure it complete and in good condition. We are a trust worthy medical equipments supplier as we have been engaged in this industry for many years. Customer will received satisfactory goods.
Satisfying all the customers' demands is our permanent pursuit. If you want to explore more or have any questions about us, please feel free to contact us.
► Changing the Target Pressure
Follow these steps to change the target pressure (default initial pressure for cuff inflation) for the current patient type:
1. Press until the message window displays TARGET PRESSURE.
The SYS window displays the current setting for initial inflation pressure.
2. Press to raise or lower the preset pressure value to the target level.
To set the displayed pressure level and return to normal operation, either do nothing for 10 seconds or press any button other than . If you press a function button (such as ) activated.
► NIBP notation can include error information:
C01 NIBP cycle cancelled by operator.
C02 Unable to calibrate.
C03 Cuff inflation to rapid.
C04 Excessive cuff inflation time.
C05 Excessive noise or air leak.
C06 Measurement out of range.
C10 Cuff overpressure.
► Performance
Systolic Range | Adult | 30 to 260 mmHg (4 to 34.5 kPa) |
Pediatric | 30 to 160 mmHg (4 to x 21.3 kPa) | |
Neonate | 25 to 120 mmHg (3.3 to 16 kPa) | |
Diastolic Range | Adult | 20 to 235 mmHg (2.7 to 31.3 kPa) |
Pediatric | 15 to 130 mmHg (2 to 17.3 kPa) | |
Neonate | 10 to 105 mmHg (1.3 to 14 kPa) | |
MAP | Adult | 20 to 255 mmHg (2.7 to 30 kPa) |
Pediatric | 15 to 140 mmHg (2 to 18.7 kPa) | |
Neonate | 10 to 110 mmHg (1.3 to 14.7 kPa) |
► Remove the NIBP board
1. Remove the four screws securing the NIBP board to the rear chassis.
2. Remove the NIBP board.
You must characterize the NIPB module whenever you replace any NIBP component (pump, tubing, air filter, check valve, or NIBP module).
If the NIBP module is not properly characterized, the pump could overinflate a neonatal cuff, which could be hazardous to neonatal patients.
The shorter tubing section contains the air filter. It connects to the pump input/ suction fitting on the outer edge of the front.
The longer tubing section contains the check valve. It connects to the pump pressure/ output fitting in the center of the pump and to the manifold on the NIBP board.