China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Mindary |
Model Number: | T1 |
Minimum Order Quantity: | 1 |
---|---|
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union,PayPal |
Product Name: | Mindray Parameter Board | Type: | T1 |
---|---|---|---|
Application: | Medical Equipment,ICU,hospital Device | Warranty: | 90days |
Color: | Green | Power Consumption: | 110V—240v |
Product Conditions: | In Good Order | Power Supply Source: | Electricity |
Management Principle: | Original Assembled Real Product, Quality Guarantee, Deliver On Time, Preference Price | Inventory Status: | Sufficient Inventory |
Peculiarity: | Professional,Useful,Durable In Use | Product Applications Scenarios: | Hospital, Clinic, Hospital Room, ICU,etc |
MEANS OF TRANSPORT: | Expressage | Minimum Purchase Commitments: | 1 Pcs |
Highlight: | Patient Monitor SpO2 Board,050-000790-01 SpO2 Board,051-000943-00 SpO2 Board |
Mindray BeneVew T1 Patient Monitor SpO2 Board 050-000790-01 051-000943-00 Parameter Board NIBP Board 051-002036-00
►Brief Introduction
NIBP
The patient monitor uses the oscillometric method for measuring the non-invasive blood pressure (NIBP). This measurement can be used for adults, pediatrics and neonates.
Non-invasive automatic monitoring of blood pressure uses the oscillometric method of measurement. To understand how this method works, we will compare it with the auscultative method. With auscultation, the doctor listens to the blood pressure and determines the systolic and diastolic pressures. The mean pressure can then be calculated with reference to these pressures as long as the arterial pressure curve is normal.
Since the monitor cannot listen to blood pressure, it measures the oscillation amplitudes of the cuff pressure. The oscillations are caused by blood pressure pulses against the cuff. The oscillation with the greatest amplitude is the mean pressure. This is the most accurate parameter measured by the oscillometric method. Once the mean pressure is determined, the systolic and diastolic pressures are calculated with reference to the mean.
Briefly, auscultation measures the systolic and diastolic pressures and the mean pressure is calculated. The oscillometric method measures mean pressure and determines systolic and diastolic pressures.
SpO2
SpO2 monitoring is a non-invasive technique used to measure the amount of oxygenated hemoglobin and pulse rate by measuring the absorption of selected wavelengths of light. The light generated in the probe passes through the tissue and is converted into electrical signals by the probe's photodetector. The SpO2 module processes the electrical signal and displays a waveform and digital values for SpO2 and pulse rate.
When monitoring SpO2 and NIBP on the same limb simultaneously, you can switch [NIBP Simul] on in the [SpO2 Setup] menu to lock the SpO2 alarm status until the NIBP measurement ends. If you switch [NIBP Simul] off, low perfusion caused by NIBP measurement may lead to inaccurate SpO2 readings and therefore cause false physiological alarms.
► Measurement Limitations
If you doubt the SpO2, measurement, check the patient’s vital signs first. Then check the patient monitor and SpO2 sensor. The following factors may influence the accuracy of measurement:
► Specification
Technique | Oscillometry |
Mode of operation | Manual, Auto and STAT |
STAT mode cycle time | 5 min |
Max measurement time | Adult, pediatric: 180 s |
Neonate: 90 s | |
Accuracy | Max mean error: ±5 mmHg |
Max standard deviation: 8 mmHg | |
Static pressure measurement range | 0mmHg to 300mmHg |
Static pressure measurement accuracy | ±3mmHg |
"Quality assurance" is our eternal pursuit and promise. Don't be hesitant to contact us! Welcome to place your orders of Mindray BeneVew T1 Patient Monitor SpO2 Board 050-000790-01 051-000943-00 Parameter Board NIBP Board 051-002036-00. Any inquiry will be highly appreciated and thanks for your support.