China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Edan |
Model Number: | IM60 |
Minimum Order Quantity: | 1 |
---|---|
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union,PayPal |
Product Name: | Edan NIBP Pump | Type: | IM60 |
---|---|---|---|
Warranty: | 90days | Applications Scenes: | Patient Monitor |
Key Word: | GE Dash4000, Encoder, Keypad Board Assembly, Function Keys | Product Status: | In Good Working Condition. |
Stock Status: | Stock Available | Minimum Purchasing Quantity: | 1unit |
PN: | 02.01.210749 | Continuous: | 5min, Interval Is 5s |
Measuring Type: | SYS, DIA, MAP, PR | Cuff Pressure Measuring Range: | 0 MmHg ~ 300 MmHg |
Highlight: | NIBP Pump Patient Monitor Parts,02.01.210749 Patient Monitor Parts |
Edan IM60 Patient Monitor NIBP Pump 02.01.210749
Edan IM60 Patient Monitor NIBP Pump 02.01.210749 Hospital Equipment Parts In Good Working Condition
► Brief Introduction
This monitor uses the oscillometric method to measure NIBP. It can be used for adult, pediatric and neonatal patients.
Oscillometric devices measure the amplitude of pressure changes in the occluding cuff as the cuff is deflated above systolic pressure. The amplitude increases suddenly as the pulse traverses the occlusion of the artery. As the cuff pressure decreases further, the pulsations increase in amplitude, reach a maximum (approximately the mean pressure), and then decrease.
In adult and pediatric mode, blood pressure measurements determined with this device comply with the American National Standard for Electronic or Automated Sphygmomanometers (ANSI/AAMI SP10-1992) for mean error and standard deviation, compared to measurements auscultatory in a representative. patient population. For auscultatory reference, the fifth Korotkoff sound was used to determine diastolic pressure.
In neonatal mode, blood pressure measurements determined with this device meet the American National Standard for Automated or Electronic Sphygmomanometers (ANSI/AAMI SP10-1992) for mean error and standard deviation, compared to intra-arterial measurements in a rep. patient population.
► Measurement Limitations
Measurements are impossible with heart rate extremes of less than 40 bpm or greater than 240 bpm, or if the patient is on a heart-lung machine.
The measurement may be inaccurate or impossible in the following situations:
► Measurement Range
Adult mode | SYS: 40 mmHg ~ 270 mmHg |
DIA: 10 mmHg ~ 215 mmHg | |
MAP: 20 mmHg ~ 235 mmHg | |
Pediatric mode | SYS: 40 mmHg ~ 200 mmHg |
DIA: 10 mmHg ~ 150 mmHg | |
MAP: 20 mmHg ~ 165 mmHg | |
Neonatal mode | SYS: 40 mmHg ~ 135 mmHg |
DIA: 10 mmHg ~ 100 mmHg | |
MAP: 20 mmHg ~ 110 mmHg |
► About Company
We have years of proven service experience in manufacturing and selling medical apparatus and instruments. Our products are all of high quality and always have won high praise from the customers at home and abroad.
Here at CWT Technology HK Limited, we offer a wide range of quality medical equipments, accessories and repair parts including patient monitor, defibrillator machine, patient monitor printer, ECG machine, EKG machine, that is specific to your clinical capabilities and fit your needs and budget, with the quality and reliability that you would expect.
Please kindly contact us, if you are interested in Edan IM60 Patient Monitor NIBP Pump 02.01.210749 , Thank you!
Contact Person: Bella
Tel: 86-18879075074