Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

philip MX40 Patient Monitor parts Spo2 Parameter Board M1020-66434

philip MX40 Patient Monitor parts Spo2 Parameter Board M1020-66434

  • philip MX40 Patient Monitor parts Spo2 Parameter Board M1020-66434
  • philip MX40 Patient Monitor parts Spo2 Parameter Board M1020-66434
  • philip MX40 Patient Monitor parts Spo2 Parameter Board M1020-66434
  • philip MX40 Patient Monitor parts Spo2 Parameter Board M1020-66434
  • philip MX40 Patient Monitor parts Spo2 Parameter Board M1020-66434
  • philip MX40 Patient Monitor parts Spo2 Parameter Board M1020-66434
philip MX40 Patient Monitor parts Spo2 Parameter Board M1020-66434
Product Details:
Brand Name: philip
Model Number: M1020-66434
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Contact Now
Detailed Product Description
Delivery Time: 3-5 Working Days Payment Terms: Full Before The Shipment
Product Name: Philip MX40 Patient Monitor Spo2 Board M1020-66434 Brand: Philip
Part NO: M1020-66434 Use For: MX40 Patient Wearable Monitor
Condition: Used Warranty: 90 Days
MOQ: One Piece Delivery Method: DHL,Fedex ,UPS Etc
Payment Method: T/T ,Paypal ,Western Union Color: Green
High Light:

philip MX40 Patient Monitor Parts

,

M1020-66434 Patient Monitor Parts

,

Spo2 Parameter Board

philip MX40 Patient Monitor Spo2 Board M1020-66434

 

 

FAST SpO2

Parameter Specification
SpO2 Measurement Range (Calibration and Display) 0 to 100%
SpO2 Accuracy See table following
SpO2 Resolution 1%
SpO2 Numerics - Averaging 5 - 20 seconds (default = 10 seconds) Note – SpO2 pulse oximetry and pulse rate are normally updated at 1 second intervals. This can be expanded as much as possible. After 60 seconds, when NIBP is measured in the same limb, the corresponding INOP message is displayed after the maximum. for 30 seconds to indicate that the displayed value is not the current value. The effect of SpO2 on average pulse oximeter data can be monitored internally by the MX40 patient-worn monitor and no user control is required.
SpO2 & Pulse Numerics - Update Rate Sent once per second. Note - SpO2 pulse oximetry readings and pulse update rates are typically 1 second. This can be extended as much as possible. 60 seconds when NIBP is measured at the same point, corresponding message INOP max 30 seconds to indicate that the displayed value is not current.
Pleth Wave- Sampling Rate 125 sps
Technical Alarms (INOPs) Activated when the sensor is disconnected, no pulse, noisy signal, detected light interference, sensor failure, measurement instability or module failure.
Wavelength Range 500-1000 nm Note – Information about this wavelength range may be particularly useful for physicians (eg, physicians performing photodynamic therapy).
Pulse Rate Measurement (available only with Continuous SpO2) Range: 30 to 300 bpm Accuracy: +/- 2% Resolution: 1 bpm
Display of SpO2 numerics SpO2 values are displayed as xxx % SpO2 to meet ISO 9919.
Emitted Light Energy < =15 mW

 

 

Company introduction

 

CWT Technology HK Limited prides itself on the quality and consistency of the products and services we provide to our customers. Our website has many options such as cables, batteries, motherboards, screens, touch screens, modules, keyboards, sensors, power sensors, etc. With many years of direct contact with customers and professional engineers with more than 12 years of experience, we always we show our craft because you feel better when you shop.

 

All orders are carefully processed as needed. We are very grateful for your purchase. Our customers always expect and receive quality products when they place orders with us. Our goal is to offer our customers the right product at the right price with fast delivery.

 

philip MX40 Patient Monitor parts Spo2 Parameter Board M1020-66434 0

We have a strong customer service team that will take care of the entire sales process. Our team is always ready to help you with returns and exchanges and listen to your complaints. Our service team follows his instructions.

 

If you're interested in M1020-66434 philip MX40 Patient Monitor Spo2 Parameter Board,feel free to contact us .Thank you .

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.