Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Module

JIKE SH330 SH360 Respiratory Humidifier Medical Equipment ICU Hospital Device

JIKE SH330 SH360 Respiratory Humidifier Medical Equipment ICU Hospital Device

  • JIKE SH330 SH360 Respiratory Humidifier Medical Equipment ICU Hospital Device
  • JIKE SH330 SH360 Respiratory Humidifier Medical Equipment ICU Hospital Device
  • JIKE SH330 SH360 Respiratory Humidifier Medical Equipment ICU Hospital Device
  • JIKE SH330 SH360 Respiratory Humidifier Medical Equipment ICU Hospital Device
JIKE SH330 SH360 Respiratory Humidifier Medical Equipment ICU Hospital Device
Product Details:
Brand Name: JIKE
Model Number: SH330 SH360
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Features: Professional, Reliable,Economic Product Name: Humidifier
Type: SH330 SH360 Application: Medical Equipment,ICU,hospital Device
Warranty: 90days Temperature Display Range: 10 – 70 °C
Gas Temperature Measurement Accuracy:: ± 2 °C Audio Information Signal:: Single Beep Or Double Beep
Rated Power:: 220 VA Mains Supply:: 115 V~, 60 Hz
Heater-plate Output:: 150 W
High Light:

SH360 Respiratory Humidifier

,

JIKE SH330 Respiratory Humidifier

JIKE SH330 SH360 Respiratory Humidifier Medical Equipment , ICU, Hospital Device

 

JIKE SH330 SH360 Respiratory Humidifier Medical Equipment

 

►Brief Introduction

The respiratory humidifier is an important medical device connected between the ventilator and the patient. Its function is to warm and humidify the inhaled gas. Good warming and humidification can prevent and reduce secondary infection of the respiratory tract in mechanically ventilated patients, as well as stimulation of the cardiopulmonary system and keep the alveoli moist. At the same time, it can reduce the consumption of heat and moisture in the respiratory tract, so that the airway is not easy to produce phlegm scabs, and can reduce the viscosity of secretions and promote expectoration.

JIKE SH330 SH360 Respiratory Humidifier Medical Equipment ICU Hospital Device 0

 

 

► Principle

The principle of the medical airway humidifier is to heat and humidify the air flow by heating and humidifying the air flow, so that the air flow passes through the hot water surface to be heated and humidified, and the heating temperature is controlled by setting the temperature control device, and this temperature can be monitored through the digital display. Using a humidifier can reduce the stimulation of mechanical ventilation to the cardiopulmonary system and improve the adaptability of patients to mechanical ventilation; keep the alveoli moist, enhance their activity, and promote gas exchange; keep the airway and airway secretions moist, which is conducive to sputum suction and Prevent airway blockage.

 

 

 

Specifications

Inlet Port/Outlet Port; 22mm OD / 15mm ID
Filling Hole: 4.3mm ID
Material Quality: Ploysulfone, Aluminum, Silica Gel
Max Volume (Max) 350mL
Working Pressure ≤6kPa
Pressure Drop ≤0.2kPa(the flow is 60L/min)
Adaptability 6ml/Kpa~12mL/Kpa
Leakage rate ≤10mL/min

 

 

 

Notice

The temperature of the ventilator humidifier is adjusted to 37-41 ℃.

1. The inspiratory filter must be installed on the ventilator end, and then connected to the humidifier.

2. The humidifier usually has a separate power cord and power switch. Be sure to turn it on after plugging in the power supply, otherwise the gas entering the patient's trachea will be dry and cold. On the contrary, it is necessary to observe and replenish the water level of the humidification tank in time to avoid overheating of the gas entering the patient's trachea caused by dry burning.

3. There may be a small temperature sensor socket on the humidifier. Be sure to plug in a special temperature sensor, otherwise it will be prone to air leakage and temperature monitoring errors.

4. If an artificial nose is used without a heated humidifier, the artificial nose must be installed between the "Y" tube and the patient's tracheal tube or tracheostomy tube.

 

 

 

If you want to explore more details about JIKE SH330 SH360 Respiratory Humidifier Medical Equipment , please let us know. Looking forward to receiving your early inquiry.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.