Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsUsed Patient Monitor

VHB10A Inspired Medical Heated Humidifier For Hospital 240V

VHB10A Inspired Medical Heated Humidifier For Hospital 240V

  • VHB10A Inspired Medical Heated Humidifier For Hospital 240V
  • VHB10A Inspired Medical Heated Humidifier For Hospital 240V
  • VHB10A Inspired Medical Heated Humidifier For Hospital 240V
  • VHB10A Inspired Medical Heated Humidifier For Hospital 240V
VHB10A Inspired Medical Heated Humidifier For Hospital 240V
Product Details:
Brand Name: Inspired
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Model Number: VHB10A Product Name: Inspired Medical VHB10A Heated Humidiffier For Hospital
Brand: Inspired Operation Voltage: 220-240V~
Rated Frequency: 50-60HZ Power Consumption: 100VA+15%
Rated Current: 0.6A Maximum At 230V Dimension: 200*140*100 Mm
Weight: 1.2kg
High Light:

VHB10A Inspired Medical Heated Humidifier

,

240V Medical Heated Humidifier

Inspired Medical VHB10A Heated Humidiffier For Hospital

VHB10A Inspired Medical Heated Humidiffier Available For Hospital

 

The VHB10A humidifier is a temperature controlled humidifier that provides thermal humidification on the patient side by connecting the humidifier to the humidifier and the atmosphere between the ventilator and the air supply for use with the ventilator. or air supply

The VHB10A humidifier has a temperature control system. Various temperature ranges can be set. between a minimum of 45°C and a maximum of 80°C after the temperature has been set. The humidifier automatically maintains and adjusts the temperature of the heating plate. The VHB10A humidifier has a safety control function that maintains the set temperature to prevent overheating. Overheating can injure the patient or damage the humidifier.

The VHB10A humidifier is suitable for use when the air volume is stable (it should be 5L/min.) In an environment with unstable air volume, the temperature and humidity of the air may not not reach the expected level.

 

 

Specification

Operation Voltage 220-240V~
Rated Frequency 50-60HZ
Power Consumption 100VA+15%
Rated Current 0.6A Maximum at 230V
Dimension 200*140*100 mm
Weight 1.2 kg

 

 

Environment

 

We recommend that you install the humidifier using the bracket on the back of the humidifier. The device should be operated in an environment free from vibration, dust, corrosive or explosive gases, and the temperature and humidity should not be extreme

 

Humidification must be applied in a horizontal position.

During operation, the angle of inclination of the humidifier and the humidification cabinet must not exceed the maximum permissible angle specified in the user manual of the humidification cabinet.

Ambient temperature: between 18°C and 28°C

Relative humidity: 15-95% non-condensing

Pressure: 86-106 kPa

 

 

useful information

When replacing the fuse, be sure to replace it with the correct type and rating, which you can obtain from the manufacturer or see the service manual. Detailed technical information can be found in the service manual.

The safe, reliable and intended use of the humidifier is based on the following requirements, among others:

Please follow the instructions for use and use when setting up and using the device and use it as directed by your doctor.

Maintenance and inspections should be performed by trained and qualified technicians.

Use by Vincent Medical Manufacturing Co., Ltd. recommended parts.

Use a proper power supply and make sure there is a good ground connection.

 

 

Install the VHB10A humidifier and chamber.

  • lUse the accessories provided with the unit for installation.
  • l Check that the humidifier is clean and dry.

 

  • l Fill the box with sterilized water until the water level reaches the highest water level marked on the box. Read the cavity description for detailed information on how to use the cavity.
  • lPush the humidifier into the opening of the humidifier, then use the humidifier to press the button on the top of the humidifier until the button pops out, indicating that the humidifier is securely in place.

VHB10A Inspired Medical Heated Humidifier For Hospital 240V 0

  • l Connect the air supply breathing tube to the chamber inlet.
  • l Connect thee inspiratory limb to the outlet of the chamber

VHB10A Inspired Medical Heated Humidifier For Hospital 240V 1

  • l Install a temperature monitoring device (thermometer, temperature sensor, etc.) on the patient's head of the inspiratory limb.

VHB10A Inspired Medical Heated Humidifier For Hospital 240V 2

  • lTurn on the fan or air supply unit.
  • l Connect the power cord to a grounded outlet, the power source must have the power specified in this manual. The humidifier and chamber are now complete.

If you're interested in Inspired Medical VHB10A Heated Humidiffier For Hospital ,feel free to contact us .Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.