Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack

6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack

  • 6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack
  • 6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack
  • 6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack
  • 6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack
  • 6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack
  • 6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack
  • 6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack
  • 6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack
  • 6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack
  • 6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack
6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack
Product Details:
Brand Name: philip
Model Number: 6802-30-66765
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Delivery Time: 3-5 Working Days Product Name: 6802-30-66765 Mindray T5 Patient Monitor Integral Module Frame Rack
Brand: Mindray Part No: 6802-30-66765
Condition: Used Suitable For: T5
Warranty: 90 Days MOQ: One Piece
Delivery Method: DHL,UPS ,Fedex ,etc Packaging: Carton
Payment Method: T/T ,Paypal ,Western Union
High Light:

6802-30-66765 Patient Monitor Parts

,

Integral Module Patient Monitor Parts

6802-30-66765 Mindray T5 Patient Monitor Integral Module Frame Rack

 

Integral Module Rack

 

The patient monitors are available in two integrated modular racks: 2-slot and 5-slot. The control board contains a NIOS II FPGA. Realizes protocol conversion and infrared communication between host and parameter module

The module rack communication card can have 2 or 3 slots. The 3-slot communication card communicates directly with the motherboard. The 2-slot communication card is connected and controlled by the 3-slot communication card. The 3-slot communication card has a communication control function. The 2-slot communication card consists of an infrared circuit and a module power supply circuit. The RS422 driver board is located on the 3-slot communication board.

 

 

 

Removing the Integral Module Rack

 

  • Disconnect the cable that connects the integrated module frame to the motherboard. Unscrew the five M3 × 8 screws and remove the built-in module holder.

6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack 0

  • Disconnect the cable that connects the communication board of the MPM frame to the communication board of the 3-slot module housing. Release the two buttons and remove the NiosII module from the 3-slot module holder.

6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack 1

  • Loosen the eight M3 × 6 screws, and then remove the 3-slot modular rack communication card and the MPM modular rack communication card.

Note: Do not forget the ground spring when assembling.

6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack 2

  • Loosen the hex nut with the sleeve. Then separate the disc, spring and contact pin.

6802-30-66765 Mindray T5 Patient Monitor Parts Integral Module Frame Rack 3

 

 

 

 

 

Module Rack Failures

 

Symptoms Possible Cause Corrective Action
Integral module rack cannot identify parameter modules Module failure Replace the parameter module. If a new module is identified, the original module is defective.
Cable defective or poorly connected

1. Check that the cables from the 3-slot module rack communication board to the MPM module rack communication board and from the module rack to the main board are properly connected.

2. Check that the connection cables and plugs are not damaged

Wrong communication board software revision Upgrade the program of the module or Integral module rack.
Module (in some slots) unrecognized Replace the corresponding module rack communication board.
Power supply to integral module rack abnormal 1. Check if voltage between two contact screws in any slot reaches 12VDC. If yes and the parameter module functions, PCB assembly in the SMR might fail. 2. If there is no 12V sent to the integrated module rack, check that power module output voltage to mother board reaches 12V DC. If yes, mother board might fail.
3-slot or MPM module rack communication board failure Replace the 3-slot or MPM module rack communication board.
Nios II module failure Replace the Nios II module.
Mother board failure Replace the mother board.

 

If you're interested in 6802-30-66765 Mindray T5 Patient Monitor Integral Module Frame Rack ,feel free to contact us .Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.