Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsUsed Patient Monitor

Used Nonin Model 7500 Pulse Oximeter Hospital Medical Monitoring Devices

Used Nonin Model 7500 Pulse Oximeter Hospital Medical Monitoring Devices

  • Used Nonin Model 7500 Pulse Oximeter Hospital Medical Monitoring Devices
  • Used Nonin Model 7500 Pulse Oximeter Hospital Medical Monitoring Devices
  • Used Nonin Model 7500 Pulse Oximeter Hospital Medical Monitoring Devices
  • Used Nonin Model 7500 Pulse Oximeter Hospital Medical Monitoring Devices
Used Nonin Model 7500 Pulse Oximeter Hospital Medical Monitoring Devices
Product Details:
Brand Name: Nonin
Model Number: 7500
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Nonin Type: 7500
Application: Pulse Oximeter Warranty: 90days
Functionality: Monitoring Patient's Health Condition Condition: In Good Working Order
Language: English,French,Italian,Spanish,Japanese,Hindi,Portuguese,Russian,Arabic, German And All The Other Languages Oxygen Saturation Display Range: 0–100% SpO2
Pulse Rate Range .: 18–321 BPM Memory: 70 Hours
Temperature (Operating): 0° To +40°C (32°F To 104°F) Temperature (Storage/Transportation): .-30° C To +50°C (-22°F To 122°F)
High Light:

Nonin Model 7500 Pulse Oximeter

,

Medical Monitoring Pulse Oximeter

 

Used Nonin Model 7500 Pulse Oximeter, Hospital Medical Monitoring Devices

 

 

► Brief Introduction

The Nonin® Model 7500 Pulse Oximeter is a portable, tabletop device indicated for use in simultaneously measuring, displaying, and recording functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate of adult, pediatric, infant, and neonatal patients. It is intended for spot-checking and/or continuous monitoring of patients during both motion and no-motion conditions, and for patients who are well or poorly perfused.

Used Nonin Model 7500 Pulse Oximeter Hospital Medical Monitoring Devices 0

This device is designed to determine the percentage of arterial oxygen saturation of functional hemoglobin. Factors that

may degrade pulse oximeter performance or affect the accuracy of the measurement include the following:

- excessive ambient light

- excessive motion

- electrosurgical interference

- blood flow restrictors (arterial catheters, blood pressure cuffs, infusion lines, etc.)

- moisture in the sensor

- improperly applied sensor

- incorrect sensor type

- poor pulse quality

- venous pulsations

- anemia or low hemoglobin concentrations

- cardiogreen and other intravascular dyes

- carboxyhemoglobin

- methemoglobin

- dysfunctional hemoglobin

- artificial nails or fingernail polish

- a sensor not at heart level

- residue (e.g., dried blood, dirt, grease, oil) in the light path.

 

 

Operating

Press the ON/STANDBY button. When the unit is first turned on, the Model 7500 performs a brief initialization sequence.

Verify that all LEDs illuminate and the unit beeps three times during the first Philipilipase of the initialization sequence.

To verify that the Model 7500 is functioning properly, it is important to monitor SpO2 and pulse rate readings. Use the following procedure to verify that the sensor is working properly.

1. Ensure that the Model 7500 is on, with the sensor connected.

2. Apply the pulse oximeter sensor (see sensor instructions for use).

3. Verify that a good SpO2 reading is displayed, that a pulse rate value appears, and that the pulse strength bargraPhilipilip LED is active.

 

 

 

Feature

Convenient – Lightweight, compact

Easy-To-Use – Bright LED displays and large display screen offer clear readability

Durable – Rugged design

Powerful – Over 70 hours of memory available for extended monitoring

Versatile – Monitors neonate to adult patients in acute care to homecare environments

Flexible – Use as a stand alone device or interface with other equipment

 

 

Specifications

Dimensions 219 mm (8.6”) W x 92 mm (3.6”) H x 142 mm (5.6”) D
Weight 900 grams (2 lbs) with battery
Power Requirements 100–240 VAC 50–60 Hz
Memory 70 hours (assuming continuous operation)
Pulse Rate Range 18–321 BPM
Oxygen Saturation Display Range 0–100% SpO2


  

Thank you for your time and interest. Any inquiry of Used Nonin Model 7500 Pulse Oximeter will be highly appreciated and thanks for your support.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.