China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | GE |
Model Number: | DASH2000 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | Refurbished GE DASH2000 Patient Monitor For Sale | Brand: | GE |
---|---|---|---|
Model Number: | DASH2000 | Height: | 21.5 Mm (8.5 Inches) |
Width: | 26.0 Cm (10.2 Inches) | Depth: | 20.0 Cm (7.9 Inches) |
Weight(with Battery Pack And Recorder): | 11.5 Lb (5.2 Kg | AC Voltage: | 100 – 240 VAC ±10% |
Power Consumption: | 16 W Normal Use, 45 W Fast Charge | Battery: | Nickel-cadmium (NiCd), 12 V, 2.0 Ampere Hours |
Display Size: | 5.8-inch Diagonal | Resolution: | 320 By 240 Pixels |
High Light: | DASH2000 Patient Monitor,Refurbished Patient Monitor,240 VAC Patient Monitor |
Refurbished GE DASH2000 Patient Monitor Standard Parameter For Sale
GE Dash2000 device is designed to monitor a fixed set of parameters such as ECG, non-invasive blood pressure, respiratory impedance, SpO2, and body temperature. Invasive pressure is an optional feature.
All patient cable connections are on the right panel of the monitor. The screen displays patient information in a logical and easy-to-understand format. The trim button control provides a single command operation for almost all monitoring functions.
Features
Technical Specifications
Display
Size | 5.8-inch diagonal |
Monochrome | Hi-Bright Liquid Crystal Display (LCD) |
Color | Liquid Crystal Display (LCD) |
Resolution | 320 by 240 pixels |
Number of traces | 3 |
Number of seconds/trace | 3.8 at 25 mm/sec |
All waveforms | 25 mm/sec –20% (with erase bar) |
Processing
Main processor | MPC 821 32-bit integrated microcontroller (24 MHz) |
Data acquisition processor | MC68332 32-bit integrated microcontroller (15.72 MHz) |
Program storage | 4-MB flash memory |
Data storage | 512 kB (battery backed-up), 4-MB DRAM |
ECG
Standard leads available | I, II, III, V, aVR, aVL, and aVF |
Leads analyzed simultaneously | I, II, III, and V (multi-lead mode) |
Lead fail | Identifies failed lead |
Alarms | User selectable upper and lower heart rate limits |
Input specifications
Voltage range | ±0.5 mV to ±5 mV |
QRS detection |
amplitude 0.5 to 5 mV with size 2x or 4x below 1 mV and with QRS time duration Adult ICU 70 to 120 ms
Neonatal ICU 40 to 80 ms |
Signal width | 40 ms to 120 ms (Q to S) |
Heart rate range | 30 to 300 BPM, accuracy ±1 BPM |
in heart rate | 12 s ±2 s (HR averaging) |
Heart rate update | 2 s |
Common mode | >10 MOhms at 50/60 Hz |
Differential | >2.5 MOhms from dc to 60 Hz |
AC voltage | 100 – 240 VAC ±10% |
Power consumption | 16 W normal use, 45 W fast charge |
Battery | nickel-cadmium (NiCd), 12 V, 2.0 ampere hours |
Min. battery operating tim | 1.5 hour |
Battery charge time to 90% | 1 hour to 3 hours |
Storage conditions Maximum | 50 °C (122 °F) at 50% relative humidity, or 70 °C (158 °F) at 15% relative humidity |
Storage conditions Minimum | -25 °C (-13 °F) |
Height | 21.5 mm (8.5 inches) |
Width | 26.0 cm (10.2 inches) |
Depth | 20.0 cm (7.9 inches) |
Weight(with battery pack and recorder) | 11.5 lb (5.2 kg |
If you're interested in Refurbished GE DASH2000 Patient Monitor Standard Parameter For Sale,feel free to contact us .Thank you .
Contact Person: Andy
Tel: 8619854815217