China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Masima |
Model Number: | 4073 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | 4073 Masima RD Rainbow SET MD20-12, Rainbow 20-Pin Patient Cable, 12 Ft. 1/Box | Brand: | Masima |
---|---|---|---|
Part No: | 4073 | Length: | 12Ft/3.7m |
Condition: | New And Original | Warranty: | 90 Days |
Delivery Time: | 3-5 Working Days | Delivery Method: | DHL,UPS ,Fedex ,etc |
Quantity: | 1 Piece /box | MOQ: | One Piece |
Highlight: | 4073 Masima Patient Monitor Accessories,MD20-12 Patient Monitor Accessories,Patient Monitor 20 Pin Cable |
4073 Masima RD Rainbow SET MD20-12, Rainbow 20-Pin Patient Cable, 12 Ft. 1/Box
DESCRIPTION
The Rainbow SET RD Series Patient Cable is used with the RD SET® Series Sensor.
The RD Series Rainbow SET Patient Cable may only be used with devices containing Masima® SET® Technology, Masima rainbow SET® version 7.1 or later, or approved for use with Rainbow® compatible sensors. Check with individual oxygen measurement system manufacturers for compatibility with specific device and sensor models. It is the responsibility of each device manufacturer to ensure that devices are compatible with each sensor model.
Sensor functions:
• Flat sensor with smooth edges fits comfortably in the patient's hand
• Lighter than traditional cable sensors
• Quick and intuitive sensor-to-wire connection with tactile and audible feedback for proper connection
• GraPHiliphhilipic sensor guide for correct sensor application
RD SET DISPOSABLE SENSOR SERIES SPECIFICATIONS
RD SET Adt/ Pdt/ Inf/ Neo/ NeoPt/ NeoPt-500 (ARMS)
SpO2 Accuracy Range | 70–100% |
No Motion | 1.5% |
Motion | 1.5% |
Low Perfusion | 2% |
PR Accuracy
No Motion | 3 bpm |
Motion | 5 bpm |
Low Perfusion | 3 bpm |
SpO2 Limits of Agreement (LoA)
Upper 95% LoA (no motion) | 2.3% |
Lower 95% LoA (no motion) | –2.3% |
Upper 95% LoA (motion) | 2.9% |
Lower 95% LoA (motion) | –2.2% |
WEIGHT RANGE
RD SET Adt | >30 kg, finger or toe application |
RD SET Pdt | 10–50 kg, finger or toe application |
RD SET Inf | 3–10 kg, thumb or great toe application |
RD SET Inf | 10–20 kg, finger or toe application |
RD SET Neo (neonatal) | <3 kg, hand or foot application |
RD SET Neo (adult) | >40 kg, finger or toe application |
RD SET NeoPt | <1 kg, hand or foot application |
RD SET NeoPt-500 | <1 kg, hand or foot application |
RD SET Disposable Sensor Series | Part Number |
RD SET Adt | 4000 |
RD SET Pdt | 4001 |
RD SET Inf | 4002 |
RD SET Neo | 4003 |
RD SET NeoPt | 4004 |
RD SET NeoPt-500 | 4005 |
RD SET Replacement Tapes/Wraps | Part Number |
Replacement Tapes, Inf | 4046 |
Replacement Tapes, Neo | 4047 |
Replacement Wraps, NeoPt | 4048 |
Replacement Wraps, NeoPt-500 | 4094 |
Cleaning
1. Remove the sensor from the patient and disconnect it from the patient cable.
2. Clean the cable by wiping the surface of the cable with a 70% isopropyl alcohol swab.
3. Clean all cable surfaces.
4. Dip another cloth or gauze in sterile or distilled water and wipe all electrode surfaces.
5. Wipe all surfaces with a clean cloth or dry gauze to dry the cables.
ENVIRONMENTAL
Operating Temperature | 41°F to 104°F (5°C to 40°C) |
Storage Temperature | -40°F to 158°F (-40°C to 70°C) |
Relative Humidity |
10% to 95% noncondensing
|
If you're interested in 4073 Masima RD Rainbow SET MD20-12, Rainbow 20-Pin Patient Cable, 12 Ft. 1/Box,feel free to contact us.Thank you .
Contact Person: Kiara
Tel: 8619854815217