China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | GE |
Model Number: | 451N |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | GE Solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N Module | Brand: | GE |
---|---|---|---|
Part No.: | 451N | Processing Main Processo: | Motorola 68000, 16/32 Bit, 14.75MHz |
Input/Output Processor: | Intel 80C152, 8-bit, 14.75MHz | Data Acquisition Processor: | Intel 80C152, 8-bit, 14.75MHz |
Sp02 Processor: | Intel 80C196, 8-bit, 7.3MHz | MOQ: | One Piece |
Warranty: | 90 Days | Delivery Method: | DHL,UPS ,Fedex ,etc |
Packaging: | Carton | Condition: | Used |
Highlight: | 8000m Marquette TRAM,451N Module Marquette TRAM |
GE Solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N Module
Tram module
Processing main processor: Motorola 68000, 16/32 bit, 14.75MHz
Input/Output Processor: Intel 80C152, 8-bit, 14.75MHz
Data Acquisition Processor: Intel 80C152, 8-bit, 14.75MHz
Sp02 processor: Intel 80C196, 8-bit, 7.3MHz
Tram module problems
data not showing
1. Verify that the patient or simulator leads are properly connected to the tram module in the tram housing.
2. Verify that the tram module is fully inserted and turned on.
3. Verify that the tram cover is open.
4. Select the Software revision menu and verify that the software file number for the RACCOMM, RACDAS or TRAM module exists. „
Item name |
GE solar 8000 8000i 8000m Marquette TRAM 451M GE TRAM 451N module
|
Brand | GE |
Model | 451N |
Use place | Hospital Devices; Medical Care; ICU; |
Deliver time | 3-5 days |
Warranty | 90 days |
Tram housing
Tram housing (remote acquisition case) to acquire patient data for patient monitor. There are two Tram 2 enclosures available for the display: „
--Tram 2 housing - accommodates one Tram module. „
--Tram - rac4A housing - contains one tram module and two additional single-height modules. Shown below is a tram-rac4a enclosure with a tram module and two single-parameter modules plugged into it.
TRAM-NET provides a network to communicate with bedside periPhilipiliperals and acquisition modules.
NOTE: If any configuration has two tram connected, there must be power. The following devices can be connected to one of the two TRAM-NET ports on the Solar8000M/i monitor. The connector is 9-pin, D-type.
Tram-rac4 housing
Tram-rac2 housing
Tram rac 4a housing with and without power
Cautions
Beware of equipment damage. Before plugging the power cord into an AC outlet, connect the trolley case to the solar powered 8000M/i patient monitor. Connecting these devices to a powered solar powered 8000M/i patient monitor may damage the connectors.
Contact Person: Kiara
Tel: 8619854815217