Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsUsed Patient Monitor

COVIDIEN Nellcorr OxiMax N560 N-560 Pulse Oximeter Hospital Medical Equipment

COVIDIEN Nellcorr OxiMax N560 N-560 Pulse Oximeter Hospital Medical Equipment

  • COVIDIEN Nellcorr OxiMax N560 N-560 Pulse Oximeter Hospital Medical Equipment
  • COVIDIEN Nellcorr OxiMax N560 N-560 Pulse Oximeter Hospital Medical Equipment
  • COVIDIEN Nellcorr OxiMax N560 N-560 Pulse Oximeter Hospital Medical Equipment
  • COVIDIEN Nellcorr OxiMax N560 N-560 Pulse Oximeter Hospital Medical Equipment
COVIDIEN Nellcorr OxiMax N560 N-560 Pulse Oximeter Hospital Medical Equipment
Product Details:
Brand Name: COVIDIEN Nellcorr
Model Number: N-560
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: COVIDIEN Nellcorr Pulse Oximeter Type: N560
Application: Pulse Oximeter Warranty: 90days
Mode Of Transport: Express Delivery Temperature Operating: 50 ºF To 113 ºF (10 ºC To 45 ºC)
Altitude/Barometric Pressure: -390 M To 3,012 M (-1,280 Ft. To 9,882 Ft.) 70 KPa To 106 KPa (20.6 In. Hg To 31.3 In. Hg) Nominal Voltage: 100 To 240 Volts AC, 25 To 39 Volt/amps To Be Compliant With IEC 60601-1 Sub-clause 10.2.2
Weight: 3.07 Lbs. (1.39 Kg) Without Pole Mount Dimensions: 2.95 " (H) × 9.06 " (W) × 5.04" (D) (75 Mm (H) × 230 Mm (W) × 128 Mm (D)
Fuses: Qty 2, 2 A, 250 Volts, Slow-blow, IEC (5 X 20 Mm) Function: Monitoring Patient's Health Condition
Apply For: Hospital, Clinic, Hospital Room, ICU, Sickroom, Ward, Bed-ward, Inpatient Ward
High Light:

COVIDIEN Nellcorr Pulse Oximeter

,

N560 Pulse Oximeter

 

Hospital Medical Equipment COVIDIEN Nellcorrr OxiMax N560 N-560 Pulse Oximeter

 

 

► Brief Introduction

The N-560 can be used for patients of all ages — infants, children, and adults. The N-560 continuously measures the patient’s pulse rate and the percentage of oxygen circulating in the blood. When either the patient’s pulse rate or the percentage of oxygen goes below or above a pre-set alarm limit, the N-560 warns you by sounding an alarm, lighting an indicator, or changing the number display from green to red.

 

 

Front Panel Control Buttons

COVIDIEN Nellcorr OxiMax N560 N-560 Pulse Oximeter Hospital Medical Equipment 0

1. Power On/Off Button

The Power On/off button is used to turn the N-560 on or off. The Power On/Off button must be pressed and held for approximately one second in order to turn the N-560 on or off.

 

2. Alarm Silence Button

The Alarm Silence button is used to silence current audible alarms for the alarm silence duration period. When an alarm has been silenced, pressing the button again reactivates, or “unsilences” the alarm.

 

3. Adjust Up Button

The Adjust Up button is used to increase variable settings of the N-560.

 

4. Adjust Down Button

The Adjust Down button is used to decrease variable settings of the N-560.

 

5. Pulse Rate Alarm Limit Button

The Pulse Rate Alarm Limit button is used to view the pulse rate alarm limit. The Adjust Up and Adjust Down buttons are used to increase or decrease the alarm limit setting. The clinician will determine if these settings need to be changed.

 

6. SatSeconds Alarm Limit Button

The SatSeconds™ Alarm Limit button is used to view the SatSeconds alarm limit. SatSeconds is an alarm management system. The clinician will determine if this feature is appropriate for the patient. The Adjust Up and Adjust Down buttons are used to change the SatSeconds limit settings.

 

7. SpO2 Alarm Limit Button

The SpO2 Alarm Limit button is used to view the SpO2 alarm limit. The Adjust Up and Adjust Down buttons are used to increase or decrease the alarm limit setting. The clinician will determine if these settings need to be changed.

 

 

Front Panel Status Indicators and Components

COVIDIEN Nellcorr OxiMax N560 N-560 Pulse Oximeter Hospital Medical Equipment 1

1 SpO2 Port (DOC-10 Cable Connection)
2 Low Battery Indicator
3 AC Power Indicator
4 Alarm Silence Indicator
5 Sensor Message Indicator
6 Sensor Off Indicator
7 Data In Sensor Indicator
8 Interference Indicator
9 Pulse Search Indicator
10 Speaker (Audible Alarms)

 

 

 

 

Thank you for your time and interest. All through the way we seek for providing perfect service to the satisfaction of customers. If you are interested in COVIDIEN Nellcorrr OxiMax N560 N-560 Pulse Oximeter, welcome to place your orders.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.