Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsUsed Ultrasound Transducer

C344 SonoScape Convex Array Transducer For S2 Portable Color Doppler Ultrasound System

C344 SonoScape Convex Array Transducer For S2 Portable Color Doppler Ultrasound System

  • C344 SonoScape Convex Array Transducer For S2 Portable Color Doppler Ultrasound System
  • C344 SonoScape Convex Array Transducer For S2 Portable Color Doppler Ultrasound System
  • C344 SonoScape Convex Array Transducer For S2 Portable Color Doppler Ultrasound System
  • C344 SonoScape Convex Array Transducer For S2 Portable Color Doppler Ultrasound System
C344 SonoScape Convex Array Transducer For S2 Portable Color Doppler Ultrasound System
Product Details:
Brand Name: SonoScape
Model Number: C344
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: C344 SonoScape Convex Array Transducer For The S2 Portable Color Doppler Ultrasound System Brand: SonoScape
Part No.: C344 Center Frequency: 3.5 MHz
Display Frequency: 2-6.8 MHz Application: Abdomen, Obstetrics, Gynecology, Urology
FOV: 70° Elements: 128
Radius: 40 Mm Image Depth: 3-240 Mm
Width Of Probe: 58 Mm Footprint: 15mm
High Light:

C344 Convex Array Transducer

,

Portable Convex Array Transducer

,

3.5MHz Convex Array Transducer

C344 SonoScape Convex Array Transducer For The S2 Portable Color Doppler Ultrasound System

 

 

 

Transducers

 

The ultrasound system supports a variety of probes, making the system very versatile

 

SonoScape S2 Portable Ultrasound supported sensors: C362, C344, L741, L742, L743, 6V1, 6V3, 2P1, 5P1, C611, VC6-2, 10L1, 10I2, 6V1A, C311, C354

 

Specification of SonoScape Convex Array Transducer C344

Center Frequency 3.5 MHz
Display Frequency 2-6.8 MHz
Application Abdomen, Obstetrics, Gynecology, Urology
FOV 70°
Elements 128
Radius 40 mm
Image Depth 3-240 mm
Width of Probe 58 mm
Footprint 15 mm

 

 

 

Attention!

 

To avoid electric shock or damage to the equipment:

1. This ultrasound system can only use supported transducers.

2. Do not use SonoScape transducers on other ultrasound systems not manufactured by SonoScape.

 

Environmental requirements

 

The sensor should be used when the following environmental requirements are met

  Operation Storage and transport
Relative humidity

30%∼75%,

no condensation

20%∼90%,

no condensation

Ambient temperature 10°C∼40°C -20°C∼55°C
Barometric pressure 700hPa∼1060hPa 700hPa∼1060hPa

 

 

Probe preparation and use

 

Inspection

After each use, or before the first use or after long-term storage of the probe, the probe must be inspected for any damage listed in the table below. If you find any damage, stop using the probe. Contact your representative as soon as possible for repairs.

Possible damage types Cracks on the probe handle (user section).

1. Cracks on the probe head (applied section).

2. Scratches on the probe head (acoustic window surface).

3. Swell of the acoustic window material.

4. Cracks or wear on the probe cable.

5. Cracks on the probe connector or any other kinds of visible damage.

  • Deformed pins or broken pins exist inside the probe connectors.

 

 

 

Preparation for Scanning

Attention!

• Effective acoustic coupling does not require excessive pressure, but requires the coupling gel to contact the patient.

• Check the expiration date of the probe sheath and coupling gel. Do not use expired probe sheaths and coupling gels.

• Latex or natural rubber contained in medical equipment or accessories can cause severe allergic reactions in some people. The FDA recommends that users identify latex-sensitive patients and be prepared to treat allergic reactions in a timely manner.

• Only apply water-soluble coupling gel on the surface of the probe. Avoid contact with mineral oil

 

Probe maintenance: cleaning and disinfection

 

Clean the transducer and probe handle after each use.

For surface probes, disinfect the transducer regularly. For intracavity probes, the transducer must be sterilized after each use.

Keep records of maintenance (inspection, cleaning, disinfection) and malfunctions.

 

Probe immersion level

 

Warning!

• Do not use solutions containing alcohol or mineral oil to clean or disinfect the probe.

• Wear sterile medical gloves to prevent the spread of potential disease. Wear glasses

If necessary.

• Do not apply a solution containing ethyl ether to the probe.

 

Cleaning procedure

1. Remove the transducer from the system. If the biopsy guide is attached to the probe, remove the biopsy guide.

2. Remove all coupling gel and rinse with a soft cloth and drinking water to clean the probe.

3. If there is too much residue on the probe surface, remove any visible residue with a damp cloth moistened with water and a mild detergent. If there is a dry residue, wipe the surface with a soft, damp cloth. Remove all the soapy water

Remove the residues with a damp cloth moistened with drinking water.

4. Air dry or dry with a soft cloth.

 

Disinfection instructions

 

The degree of disinfection is directly related to the length of time of contact with the biocide. It is recommended to perform high-level disinfection of surface probes and intracavity probes1. It is strongly recommended to use legally sold liquid chemical fungicides (such as Cidex). Prepare and use the following fungicides

Manufacturer's instructions.

 

1. Make sure that all visible residues have been removed.

2. Prepare the disinfectant solution according to the manufacturer's instructions. Please also store and dispose of the biocide in accordance with the manufacturer's instructions.

3. Immerse the probe in the biocide at the interval specified by the biocide manufacturer.

The immersion level should be kept below the binding line. It is recommended to carry out high-level disinfection of surface probes, and high-level disinfection of intracavity probes. Note that you may need to rotate and shake

Transducer to remove air bubbles between the surface of the transducer and the biocide solution.

4. After removing the probe from the disinfectant solution, rinse it thoroughly with clean drinking water to remove all visible disinfectant. Wipe the probe dry with a soft cloth.

 

 

 

If you have any interest in SonoScape Convex Array Transducer C344,feel free to contact us .

 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.