Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Module

2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP

2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP

  • 2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP
  • 2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP
  • 2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP
  • 2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP
2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP
Product Details:
Brand Name: GE
Certification: CE
Model Number: 2060241-001
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Contact Now
Detailed Product Description
Delivery Time: 3-5 Working Days Payment Terms: Full Before Shipment
Product Name: 2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP Brand: GE
Part No: 2060241-001 Monitor Parameters: ECG, O2 - SpO2, Blood Pressure - NIBP, Temperature
Condition: Excellent MOQ: One Piece
Delivery Method: DHL ,UPS ,Fedex Payment Method: T/T ,Paypal ,Western Union
Application: Hospital Devices; Medical Care; ICU;
High Light:

B20i Patient Monitor Parameter Module

,

SPO2 Patient Monitor Parameter Module

,

2060241-001 Patient Monitor Module

 

2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP

 

Connection of ECG equipment to patient

(1) ECG connector

(2) Multi-Link 5-lead ECG trunk cable or 3-lead ECG cable

(3) 3 or 5 lead set

Note: For a complete list of accessories, see "Consumables and

The "Accessories" catalog comes with the monitor. Check

The expiry date of the ECG electrodes.

Note: Keep the ECG cable, lead set and module connector dry.

Avoid excessive use of liquids when cleaning cables and connectors.

Note: In a 5-lead ECG, place the fifth electrode (C/V) in one of the six electrodes

Indicate the place and select the corresponding V lead label.

Item name GE B20i patient monitor parameter module with IBP SPO2 ECG NIBP 2060241-001
Brand GE
Model GE B20i patient monitor parameter module with IBP SPO2 ECG NIBP 2060241-001
Use place Hospital Devices; Medical Care; ICU;
Deliver time 3-5 days
Warranty 90 days

 

 

 

 

2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP 0

 

 

 

Pulse oximetry (SpO2)

 

Measurement limits

− Pulse oximeter cannot distinguish oxygenated hemoglobin

And hemoglobin is abnormal.

− When using ear probes, poor perfusion may affect the accuracy of the measurement.

− To avoid false readings, do not use blood pressure cuffs or

An arterial blood pressure measuring device in the same limb as the sensor.

 

SpO2 configuration

The monitor has three SpO2 configuration options: GE TruSignal,

Massimo and Nelco. This setting will be pre-configured by the manufacturer according to your choice. Different settings may have different performance, please refer to "Technical Specifications"

more details.

 

Massimo

5,758,644,6,011,986,6,699,194,7,215,986,7,254,433,7,530,955 and

Other applicable patents

Nellcorrr

5,485,847; 5,676,141; 5,743,263; 6,035,223; 6,226,539; 6,411,833;

6,463,310; 6,591,123; 6,708,049; 7,016,715; 7,039,538; 7,120,479;

7,120,480; 7,142,142; 7,162,288; 7,190,985; 7,194,293; 7,209,774;

7,212,847; 7,400,919

 

SpO2 and patient connection

(1) Compatible SpO2 measurement capability

(2) Interconnect cable

(3) Reusable sensor

(4) Disposable sensor

2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP 1

 

Prepare the patient for SpO2 measurement

1. Connect the sensor to the blue connector in the display.

2. Clean the surface of the reusable sensor.

3. Clean the application area. Remove nail polish, artificial

Nails, earrings, etc.

4. Cut long nails.

5. Connect the sensor cable to your wrist or bedding to prevent

The cables and sensors move.

6. Check if the red light is in the sensor.

7. Check whether the waveform and parameter values ​​are displayed

When the probe is connected to the patient.

Note: Only use dry and clean sensors.

Note: Do not use blood pressure cuff or arterial sPhilipilipygmomanometer

A measuring device located on the same limb as the sensor.

Note: GE Healthcare sensors do not contain latex. Reference introduction

Each type of probe to ensure the materials used

The patient or any other person may come into contact with it.

 

Select SpO2 heart rate

Heart rate can come from many sources. show

Pulse rate measured by pulse oximeter:

1. Press the SpO2 key.

2. Select HR source-Pleth.

NOTE: Art, ABP, UAC is visible when a related label is selected.

Note: The AUTO selection priority for heart rate calculation is:

ECG (the lead with the highest R wave), pressure (Art, ABP, UAC), and

The plethysmograPhilipilipy pulse waveform.

 

Adjusting SpO2 pulse beep tone volume

You can adjust the volume of the beat sound:

1. Press the SpO2 key.

2. 2. Select Beat Sound Volume.

 

 

 

Non-invasive blood pressure (NIBP)

NIBP to patient connection

  • NIBP connector in monitor
  • Cuff hose
  • Cuff of correct size
  • Brachial artery arrow (printed on cuff)
  • Cuff index line (printed on cuff)

 

 

2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP 2

 

Invasive blood pressure

IBP equipment to patient connection

  • Compatible IBP measurement capability
  • Fluid bag or bottle with pressure infusor
  • Flushing set
  • Disposable catheter
  • Transducer
  • Adapter cable for the IBP transducer
  • Adapter cable for dual IBP measurement

2060241-001 GE B20i Patient Monitor Parameter Module With IBP SPO2 ECG NIBP 3

 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.