China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Masi-mo |
Certification: | CE |
Model Number: | MX-5 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | MX-5 Masi-mo Rainbow SET SpO2 Pulse Oximeter Circuit Board Spare Parts | Brand: | Masi-mo |
---|---|---|---|
Model: | MX-5 | Width: | 2.0 Inch |
Length: | 2.5inch | Thickness: | 0.062inch |
Top Height: | 0.2 Inch | Bottom Height: | 0.1inch |
Mounting Hole: | 0.125 Inch | Type: | Oxygen Sensor |
Stock: | Enough | Warranty: | 90 Days |
MOQ: | One Piece | ||
High Light: | SpO2 Pulse Oximeter Circuit Board,Masi-mo MX-5 Oximeter Circuit Board |
MX-5 Masi-mo Rainbow SET SpO2 Pulse Oximeter Circuit Board Spare Parts
Board Dimensions
Board Dimensions | Typical |
Width | 2.0 inch |
Length | 2.5inch |
Thickness | 0.062 inch |
Top Height | 0.2inch |
Bottom Height | 0.1inch |
Mounting Hole | 0.125inch |
Connector Data
Connector Description | Power and communications connector | Sensor connector |
Number of Pins | 10 | 20 |
Configuration | 2 rows of 5 | 2 rows of 10 |
Angle | Vertical | Vertical |
Pin Grid | 0.050 inch | 0.050 inch |
Manufacture Part# | Samtec SFM-105-02-S-D-A | Samtec SFML-110-T2-S-D-A |
DC power requirments
Typical | Maximum | |
Input Voltage | +5v | +0.25v |
Line/Load Regulation | 1.0% rms | |
AVG.Power (Rainbow SET) | 350 mW | 500W |
AVG.Power(Masi-mo set) | <150mW |
Serial Interface
Default | Maximum | |
Baud Rate(Configurable) | 9600 bps | 115200bps |
Size :
Dimensions: 2 inches x 2.5 inches
Board thickness: 0.062 inches
Mounting hole diameter: 0.125 in
Masi-mo's revolutionary non-invasive surveillance technology can be integrated into a range of multi-parameter and multi-function surveillance devices through our MX and MSX series circuits.
When used with Masi-mo Rainbow® Multi-Wavelength LED Sensors, the MX-Series Board can provide a full set of Masi-mo Rainbow® measurements, including total hemoglobin (SPhilipilipb®), oxygen content (SpOC ™), carboxyhemoglobin (SpCO®), Methemoglobin (SpMet) ®) and acoustic respiratory rate (RRa®) and Masi-mo SET® Low Perfusion Motion and Low Perfusion ™ pulse oximetry measurement of SpO2, heart rate, perfusion rate and plethysmograPhilipilipic variability index (PVi®).
About Masi-mo MX-5 board
The Masi-mo MX-5 OEM circuit board is a technology platform that utilizes approximately half the power of previously available Rainbow® circuit board and provides a groundbreaking Rainbow® non-invasive pulse oximetry measurement. The MX-5 is also unique in that it can still dynamically adjust power consumption according to the type of parameter being measured.
Original equipment manufacturers (OEMs) use Masi-mo circuit board to perform non-invasive Masi-mo SET® Measure-Through Motion and Low Perfusion ™ pulse oximetry measurements and Rainbow® Pulse CO oximetry measurements on their own medical equipment and patient monitors. To achieve the high-performance, non-invasive measurement function of Rainbow® Pulse CO Oximetry, an average of 550 millivatts of power is required to date. The new MX-5 plate has a lower power consumption of 250-320 millivat on average, depending on the measured rainbow parameters. Reducing power consumption by about 50% is expected to facilitate integration with next-generation patient monitoring solutions, which require more efficient power management solutions to enable smaller, lighter and more mobile battery-powered devices.
Compared to the previous Rainbow® card, the MX-5 not only increases lower power consumption but also dynamic power consumption, allowing the MX-5 to adjust power consumption to a controlled combination of parameters, giving longer battery life. For example, if only Masi-mo SET® SpO2 and heart rate are monitored, the average power consumption of the MX-5 will be reduced by more than 75% compared to the previous Rainbow® card. The Masi-mo MX-5 has the same dimensions as its predecessor, the MX-3, 2 "x 2.5", and allows for a simple expansion replacement.
The Masi-mo MX-5 OEM board uses only 50% of previous power requirements without affecting performance. It offers all the features of groundbreaking Rainbow® technology to control total hemoglobin (SPhilipilipb®), oxygen concentration (SpOC ™), carboxyhemoglobin (SpCO®) in non-invasive measurements, methemoglobin (SpMet®) and acoustic respiration rate (RRa ®). In addition, the Masi-mo SET® pulse oximeter offers the "Measurement with training and hypoperfusion oxygen saturation (SpO2)" measurement function, heart rate and perfusion index (PI).
Rick Fishel, CEO of Masi-mo Global OEM Business and Corporate Development, said: "The powerful MX-5 board represents Masi-mo's commitment to continuous technological improvement, including integrating OEM's innovative, non-invasive Rainbow measurement into smaller, more portable ones. and development enhanced "Ability to monitor devices for a variety of existing and new healthcare applications. Circulatory innovations such as the MX-5 provide non-invasive rainbow pulse oximetry measurement features that enable Philipilipysicians to obtain up-to-date information on patients' Philipilipysiological status, which may lead to better outcomes. "
Contact Person: Andy
Tel: 8619854815217